Skip to main content
Searching for products?
Click here to shop our online store
2251-2275 of 2445 Resource Library
2251-2275 of 2445 Resource Library
GUIDE
  Introduction Gas Chromatography Mass Spectrometry (GC-MS) instrument performance is dependent upon proper operation, use of the correct consumables, and following manufacturer guidelines. Here we show a list of some of the best and worst practices …
BROCHURE
  Introduction Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate …
WHITE PAPER
    Introduction Want to know what the future might look like for plastic manufacturers and recyclers? The whole industry has undergone tremendous change and continues to do so. Manufacturing and recycling are drawing closer, in order to meet global …
PRODUCT NOTE
          Introduction Supporting unparalleled sensitivity, pinpoint precision, and ultimate ease-of-use, the HS 2400 ™ Headspace Sampler pairs with most standard GC Systems and features patented pressure balance sampling technology that allows precise …
APPLICATION NOTE
          Introduction Hydrogen is used in a number of areas, from industrial processes such as pesticide production and the removal of sulfur from petrochemical products to its use as a fuel and in power generation. To ensure the quality of hydrogen, …
FLYER
  Introduction Built on robust, flexible technology that enables labs to comply with ISO 17294-2, PerkinElmer’s ISO 17294 Water Analyzer allows you to quickly begin analyzing drinking and surface water samples using a complete, end-to-end workflow, …
ARTICLE
  Introduction Successfully install your GC inlet liner in a split/splitless inlet for your GC 2400 gas chromatograph with these helpful and simple steps. The lessons also largely apply to liner installation in any split/splitless inlet, though, so even …
APPLICATION NOTE
  Introduction Controlled cooling in the DSC represents a way to extract information from food products not normally accessible by other methods. Extra virgin olive oils have a distinct cooling profile that is different from lesser grades and apparently …
BROCHURE
  Introduction PerkinElmer offers a portfolio of high-performance solutions to optimize your laboratory workflow for PFAS analysis. Our robust and reliable LC/MS/MS systems along with high quality consumables and the industry’s most trusted service and …
BROCHURE
  Introduction The development of alternative-protein and plant-based food products helps meet the growing need around the world for nutritious, sustainable foods. But these novel foods can be challenging to develop and manufacture. R&D and formulators …
FLYER
  Introduction For labs conducting routine elemental analysis, simplified and streamlined workflows are critical to success. Syngistix™ for ICP software for the Avio® Max ICP-OES series is engineered with an assortment of smart features, streamlining …
INFOGRAPHIC
  Introduction Productivity means everything to your lab. No matter what size or type you supervise, chances are you're in need of process optimization to ensure faster time result and greater cost savings. However, a study found that 25% of lab analysts' …
FAQ
  Introduction The regulations of 21 CFR Part 11 cover overall system compliance and include administrative, procedural and technical elements. Software alone cannot be compliant without the development and implementation of the other elements. …
BROCHURE
    Introduction Perten has a wide array of process monitoring solutions to meet the diverse needs of the food industry, from grain harvest, to flour and corn milling, oil seed processing, dairy production, sugar refining, meat and poultry processing, and …
CASE STUDY
  Introduction The science and art of creating and maintaining thriving agricultural ecosystems requires cultivating healthy soil, crops and livestock. The safety and efficacy of agricultural chemicals and their uptake into our food supply requires …
FLYER
  Introduction What if there was a one-stop service contract option for your lab –from a company with decades of deep-seated multivendor experience? – that repaired all your instruments, offered state-of-the-art validation? and compliance services, and …
BROCHURE
  Introduction Sample handling is an important aspect of any successful trace elemental analysis, with on-line procedures for sample preparation and delivery increasingly becoming methods of choice as the demands for productivity increase. Flow injection …
APPLICATION NOTE
  Introduction Titanium (Ti) alloys are well-known superalloys due to their high strength-to-weight ratio, excellent mechanical properties, corrosion and high temperature resistance and biocompatibility. In current national standards (e.g., ASTM E2371-13, …
BROCHURE
  Introduction The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. …
APPLICATION NOTE
  Introduction Histamine is a contaminant that can be found in seafood when improperly handled or stored, causing scombroid food poisoning. The MaxSignal® Histamine Enzymatic Assay Kit enables international and government regulatory agencies, food …
PRODUCT NOTE
    Introduction PerkinElmer’s LPC 500 Liquid Particle Counter is a single particle optical sizing system designed to count and size particles individually with high resolution. When used for in-service oil samples, only 3 to 4 mL of 10x diluted samples …
FLYER
  Introduction Histamine is a contaminant sometimes found in seafood when improperly handled. High levels of histamine in seafood are often associated with scombroid poisoning, a bacterially induced illness from spoiled fish. Scombroid poisoning triggers …
GUIDE
  Introduction During gas chromatography (GC) column installation, ferrules are used to provide a leak-free seal. Different materials and configurations of ferrules are available, the choice of which depends on your application and use within the GC …
GUIDE
  Introduction Headspace Gas Chromatography (HS-GC) instrument performance is dependent upon proper operation, use of the correct consumables, and following manufacturer guidelines. Here we show a list of some of the best and worst practices during set-up …
GUIDE
  Introduction Establishing the basics is important when it comes to Chromatography. Whether you're looking to brush up your knowledge on the difference between HPLC and UHPLC, or looking for tips on choosing the right Stationary Phase/Bonding Chemistry …