LAMBDA 35 Double-beam UV/Vis performance, built for the everyday workload.
Routine absorbance, concentration and kinetics work shouldn't need a specialist. LAMBDA 35 gives QC and teaching labs validated double-beam measurement, a sample compartment that takes the accessories you already own, and a workflow anyone on the bench can run on day one.
Two configurations · Ships with UVWinLab™ software · 3-year warranty

Overview
Everything routine UV/Vis asks for. Nothing it doesn't.
LAMBDA 35 sits below the LAMBDA 365+ in the family: the same double-beam optical bench discipline and the same accessory ecosystem, specified and priced for labs whose day is concentration curves, purity checks and method-driven QC rather than research-grade materials characterisation.
Stable from switch-on
Double-beam optics correct for lamp drift in real time, so the first reading of the morning is as trustworthy as the last of the afternoon - no warm-up ritual, no reference re-runs.
Accessories you already own
The sample compartment and mounting geometry are shared with the LAMBDA 365+ family, so existing cell holders, sippers and water-jacketed cuvette blocks carry straight over.
Method, not menu
Saved methods put scan, fixed-wavelength, quantification and kinetics one tap from the home screen, with the parameters locked so every operator runs the assay the same way.
Audit-ready when you need it
Add the Enhanced Security™ option for 21 CFR Part 11 audit trails, electronic signatures and user-level permissions without changing the instrument on the bench.
Choose your configuration
Two ways to run LAMBDA 35
Identical optics and identical performance. The difference is how you drive it - and whether the instrument needs to stand alone on the bench.

LAMBDA 35
For labs already standardised on UVWinLab, LIMS-connected workstations or shared PCs. Lowest entry price in the family.
- ControlUVWinLab on PC
- Onboard screen—
- Wavelength range190–1100 nm
- Spectral bandwidth1.0 nm
- Stray light< 0.05 %T
- Standalone operation—
Part no. N41000XX

LAMBDA 35 Touch
Runs methods, stores results and prints reports with no computer attached - for teaching labs, QC benches and anywhere a validated PC is a burden.
- ControlOnboard touchscreen or PC
- Onboard screen7 in colour touch
- Wavelength range190–1100 nm
- Spectral bandwidth1.0 nm
- Stray light< 0.05 %T
- Standalone operationYes · stores 1000 methods
Part no. N41000YY
Not sure which? If the instrument will sit on a bench with a validated PC beside it, LAMBDA 35 is the lower-cost route. If it moves between rooms, teaches students, or has to produce a printed result without IT involvement, choose Touch.
Bundles
Choose a bundle
Start from the bundle closest to your workload, tick the options you want, and send your selection to our team. You'll get a tailored quote and lead time back without briefing anyone from scratch.
Instrument
Most popular
Compliance
Regulated QC needing audit trails and qualification
Illustrative pricing for concept review only, not approved list prices. Bundle contents are indicative. Excludes installation, shipping and local taxes.
Specifications
Technical specifications
Figures apply to both configurations unless a row says otherwise. Draft values shown and will need to be replaced by the approved datasheet before publication.
| Optical design | Double beam, ratio recording |
|---|---|
| Monochromator | Holographic concave grating, 1053 lines/mm |
| Light sources | Pre-aligned deuterium and tungsten halogen |
| Detector | Dual silicon photodiode |
| Source change | Automatic at 326 nm, user-selectable |
| Beam height | 15 mm |
| Range | 190–1100 nm |
|---|---|
| Spectral bandwidth | 1.0 nm fixed |
| Accuracy | ±0.3 nm |
| Repeatability | ±0.1 nm |
| Scan speed | 7.5–2880 nm/min |
| Photometric range | ±3.5 A |
|---|---|
| Photometric accuracy | ±0.003 A at 1 A |
| Stray light | < 0.05 %T at 220 nm and 340 nm |
| Baseline flatness | ±0.001 A |
| Included software | UVWinLab, standard edition |
|---|---|
| Compliance option | Enhanced Security (21 CFR Part 11) |
| Measurement modes | Scan, fixed wavelength, quant, kinetics, multi-wavelength |
| Export | CSV, ASCII, PDF report |
| Dimensions (W × D × H) | 560 × 450 × 220 mm |
|---|---|
| Weight | 18 kg |
| Operating temperature | 15–35 °C |
| Power | 100–240 V, 50/60 Hz |
Applications
What labs run on it
Six starting points, and each one still requires a published method. Every link below should resolve to an application note a customer can read without a form gating their access.
Pharmaceuticals
Identity and purity checks, dissolution profiling and content uniformity against compendial methods, with Part 11 audit trails when required.
Water & environmental
Nitrate-nitrogen, hexavalent chromium, colour and turbidity by established photometric methods, with reagent kits and cell holders listed alongside.
Food & beverage
Colour grading, polyphenol and total phenolic indices, sugar and additive quantification for incoming goods and finished product release.
Chemicals
Raw material verification, reaction kinetics and colour consistency across batches, with saved methods so any operator reproduces the run.
Coatings & films
Transmission and absorbance of thin films and filters up to the NIR edge, for incoming QC where full UV/Vis/NIR range isn't needed.
Teaching & academia
Beer–Lambert practicals and enzyme kinetics on a standalone instrument students can operate without a lab PC or a login.
Software & compliance
One software family, from teaching bench to audited QC
LAMBDA 35 runs the same UVWinLab software as the rest of the family, so methods, reports and training transfer with the instrument rather than being relearned.
UVWinLab, standard
Included. Scan, quant, kinetics and multi-wavelength methods, batch sample tables, and report templates you can lock for routine use.
Enhanced Security™ option
21 CFR Part 11 support: user permissions, electronic signatures, full audit trail and tamper-evident data files for regulated environments.
Onboard method store
On LAMBDA 35 Touch, methods and results live on the instrument and export to CSV or PDF over USB or network - no workstation to validate.
Resources
Brochures, methods and training
Everything a buyer needs to specify, justify and get started. We don't want these sat behind gating forms, this should be a frictionless experience.
LAMBDA 35 product brochure
Eight pages on configurations, accessories and the applications the instrument is specified for.
LAMBDA 35 specification sheet
Full optical, photometric and environmental specifications for both configurations, with part numbers.
Choosing your UV/Vis: 35, 365+ or 465
A one-page decision guide across the family, by sample type, throughput and compliance need.
Accessories & consumables guide
Cell holders, sippers, temperature control and cuvettes, with the part numbers that fit LAMBDA 35.
Nitrate-nitrogen in drinking water
Method, calibration range and repeatability data for routine compliance monitoring.
Total polyphenol index in red wine
Sample dilution, wavelength selection and results across a vintage set.
Content uniformity by UV absorbance
A compendial-style workflow with locked methods and a signed report output.
Enzyme kinetics for the teaching lab
A practical students can run standalone, with expected curves and common pitfalls.
Unboxing to first result in 10 minutes
The out-of-box sequence, filmed uncut, on the Touch configuration.
Building a locked quant method
Three minutes on setting up a method operators can run but not alter.
Part 11 for small QC labs
What compliance actually requires of a UV/Vis instrument, and what it doesn't.
Operator certification course
Half-day online course with an assessment and a certificate for your training records.
Service & support
After the order
The part of the decision a customer buying without a sales visit worries about most.
Installation & IQ/OQ
Engineer-led installation with documented qualification, or a self-install kit with a guided verification routine where budget matters more than paperwork.
Warranty & service plans
Three-year instrument warranty as standard, with preventive maintenance and priority-response plans available at the point of quote.
Training & method help
Free operator basics online, plus application specialists who will help transfer an existing method onto the instrument.
Questions
Questions sales would answer
These should be written for a buyer who will never speak to us. Note that all Answers are drafts.
LAMBDA 35 has a fixed 1.0 nm bandwidth and a ±3.5 A photometric range, which covers routine concentration, purity and kinetics work. LAMBDA 365+ adds variable bandwidth from 0.5 to 20 nm and measurement of high-absorbing samples to 4 A, which matters for method development and unusual sample types. Both share the accessory ecosystem and UVWinLab software.
Yes for the mid-range accessory set - cell holders, sippers, water-jacketed blocks and multi-cell changers designed for LAMBDA 265/365+ mount directly. Accessories built for the 850+/1050+ large sample compartments do not fit.
Only for the base LAMBDA 35. The Touch configuration runs methods, stores results and prints reports on its own, and can still be connected to UVWinLab when you want centralised data.
With the Enhanced Security option, yes - it provides the audit trail, electronic signature and access-control features needed to support 21 CFR Part 11 workflows. Qualification services are available separately.
Request a quote here and it is priced against your region and any framework agreement. Where e-commerce is available, both configurations can be ordered directly from the shop; lead time is confirmed on the quote.
Ready to choose the LAMBDA 35?
Choose a bundle configuration from our options and we'll send it directly to Sales.