PerkinElmer
check quantity

Avio 220 Max ICP-OES Concentric/Cyclonic Configuration

The Avio® 220 Max is a compact, hybrid simultaneous ICP-OES instrument, ideal for labs with low-to-medium throughput requirements. Its unique plug-and-play capabilities make the Avio 220 Max the ICP with the fastest startup on the market – cold start to analysis in only 10 minutes – saving you time and operating costs by allowing you to shut down the instrument between runs. Plus, it utilizes a vertical plasma and is engineered to handle even the most difficult, high-matrix samples without dilution, delivering productivity, performance and faster return on investment. And last but certainly not least, Syngistix for ICP software provides an intuitive and smart environment with smart monitoring for real-time instrument and sample diagnostics as well as results viewing to easily track sample analysis, quality control, and internal standard performance to guarantee sample accuracy.

Part Number
Model Name
N0790004
Avio 220 Max Scott/Cross-Flow
more
N0790005
Avio 220 Max Concentric/Cyclonic
more
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Proprietary features on the Avio 220 Max ICP-OES include:

  • Plug-and-play functionality allows for fast startup - cold start to analysis in just 10 minutes
  • Simultaneous acquisition of analyte and background with increased analyte sensitivity
  • Flat Plate plasma technology delivers a more robust, stable plasma, the lowest argon consumption of any ICP, and is maintenance-free
  • PlasmaShear system offers maintenance-free, argon-free interference removal
  • Attenuation mode reduces the signal without manual dilution, with just a click of a button, and is fully customizable by each wavelength
  • Vertical plasma torch design provides 100% matrix tolerance, minimizing sample preparation time
  • Dual view optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength
  • Double-monochromator optical system brings outstanding analytical performance
  • Color PlasmaCam provides continuous viewing of the plasma, simplifying method development and enabling remote diagnostic capabilities
  • Syngistix for ICP Software delivers an intuitive, left-to-right, icon-based design, mirroring the progression of your workflow with smart features that guide you through each step for greater control and confidence

And for added flexibility, the Avio 220 Max is available in two configurations, allowing you to select the option best suited for your application(s). This configuration of the Avio 220 Max is equipped with Cyclonic/Concentric sample introduction to provide higher efficiency, better precision, and faster washout times. This configuration is not recommended for hydrofluoric acid applications.

Specifications

21 CFR Part 11 Compatible Yes
Depth 76.0 cm
Height 81.0 cm
Model Name Avio 220 Max Concentric/Cyclonic
Warranty 1 Year
Weight 100.0 kg
Width 65.0 cm
Resources, Events & More
  • All

Application Note

Analysis of Copper-Gold Ore with the Avio 220 Max ICP-OES

The extraction of metals from ore at a mining plant requires the routine analysis of various samples, which include the feed (crushed ore), the tails (waste ore after processing) and the concentrate (final product). In this work, reference materials were analyzed for copper (Cu), iron (Fe), silver (Ag) and arsenic (As) using the Avio® 220 Max hybrid simultaneous ICP-OES, ideal for laboratories looking to improve productivity for analyses usually performed with flame atomic absorption spectroscopy, which can only measure one element at a time.

PDF 1 MB
Analysis of In-Service Oils Following ASTM D5185 with the Avio 220 Max ICP-OES

With heavy machinery, it is important to assess its status during operation to prevent breakdowns and costly repairs. A key aspect is monitoring the status of the oil or lubricants used to lubricate various components such as engines, transmissions, gearboxes and many other important areas: if the oil degrades too much or becomes highly contaminated, it can damage various components. Because of its importance, ASTM created a method for the analysis of in-service oils: method D5185.

This work demonstrates the ability of the Avio® 220 Max hybrid simultaneous ICP-OES to perform a common implementation of ASTM method D5185 for in-service oil analysis.

PDF 1 MB
Analysis of SiO2- and TiO2-Containing Medications Using ICP-OES Following USP 232/233 Guidelines with Software Designed to Aid in 21 CFR Part 11 Compliance

Since early 2018, manufacturers of pharmaceutical products are mandated to comply with USP <232/<233> requirements around the analysis of elemental impurities in medications. This work demonstrates the ability of PerkinElmer’s Avio® 220 Max hybrid simultaneous ICP-OES to pass validation testing for Class 1 and 2A elements for USP <232>/<233> methodology, while allowing labs to comply with 21 CFR Part 11.

PDF 2 MB
Early Detection of Chloride in 3-MCPD Precursors in Palm Oil through the Analysis of Chloride in Edible Oil with the Avio 220 Max ICP-OES

During the production of palm oil, 3-MCPD forms from the reaction of acylglycerol with the chloride ion (Cl-). 3-MCPD is a potentially carcinogenic compound, with a tolerable daily intake of 2 µg/kg of bodyweight. As a result, the palm oil industry limits the 3-MCPD concentration to less than 10 mg/kg.

Because 3-MCPD only forms in the presence of Cl-, removal of free Cl- is critical. Chloride is introduced from the raw palm fruit, which accumulates Cl- by uptake from the soil, water, and fertilizer. During the processing of the palm fruit, steam is introduced to remove as much Cl as possible. However, if all Cl is not removed, 3-MCPD can be formed in further refining steps. Therefore, after initial processing, the crude palm oil (CPO) must be monitored for chloride content.

This work describes the ability to measure chloride extracted from palm oil by ICP-OES, leveraging the unique capabilities of the Avio® 220 Max hybrid simultaneous system.

PDF 1 MB

Brochure

Avio Max Series ICP-OES Interactive Brochure

Nowadays, laboratories are expected to tackle quick turnaround times and meet lower detection limits, while at the same time deliver high levels of sample accuracy – and although workloads and workflows may vary, the need to work quickly doesn’t. Plus, labs are looking to lower operating costs and reduce maintenance.

Meet the Avio® Max series – the ICP-OES systems that are as comfortable with multitasking as you are. No matter your workload or workflow needs, you can rely on the Avio Max series for robust and low-maintenance ICPs, delivering ease of use with intuitive, smart software and low cost of ownership.

Learn more about the advantages of the Avio Max series ICP-OES – download the interactive brochure.

PDF 3 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and it’s clear: you’re creating a complete nutritional delivery system, not just a simple mix of grains.

PDF 3 MB

Product Note

Avio 220 Max Hybrid Simultaneous ICP Optical Emission Spectrometer

The Avio® 220 Max, the industry's only hybrid simultaneous ICP-OES, is a robust and matrix-tolerant system with plug-and-play performance taking you from cold start to analysis in just 10 minutes – ideal for labs with low-to-mid throughput requirements. The instrument’s performance is further optimized by Syngistix for ICP software, thanks to a host of smart features developed with the user in mind, providing smart workflows, smart monitoring and smart data.

Download this product note to learn more about the unique advantages of the Avio 220 Max, the ICP-OES system that takes “everyday” to a new level.

PDF 627 KB
Syngistix Cross-Platform Atomic Spectroscopy Software

PerkinElmer's Syngistix is a workflow-based software designed to offer a harmonized user experience across PerkinElmer’s AA, ICP and ICP-MS platforms.

PDF 757 KB

Technical Note

Avio 220 Max ICP-OES Custom-Designed Solid-State Detector with Hybrid Simultaneous Analysis

The Avio® 220 Max hybrid simultaneous ICP-OES features a dual backside illuminated charge-coupled device (DBI-CCD) detector which simultaneously measures a wavelength range around the analytical wavelength (within a given CCD array), including the background correction wavelength(s). Unique to the Avio 220 Max, background correction readings are made at exactly the same time as analyte measurements with significant improvements in analytical accuracy.

Read more about the Avio 220 Max’s solid-state detector with hybrid simultaneous analysis – download this technical note.

PDF 683 KB
Avio Max Series ICP-OES Solid-State RF Generator for Flat Plate Plasma

PerkinElmer's Avio® Max series ICP-OES spectrometers feature a free-running solid-state RF generator for Flat Plate plasma, a proprietary technology which generates a transversely symmetrical plasma, replacing previous helical-coil induction. This approach produces a flat-bottom shaped plasma which prevents sample and vapors from escaping around the outside. With Flat Plate technology, the same robust, matrix-tolerant plasma is generated and maintained with approximately half the argon consumption of helical load-coil systems. Maintenance-free, this innovative approach to RF generation minimizes operating costs without compromising performance.

Download this technical note to learn more about the Avio Max series' RF generator and Flat Plate plasma technology.

PDF 627 KB
Flat Plate Plasma Technology on the Avio Max Series ICP-OES

A robust and stable plasma is essential when performing analytical analyses by inductively coupled plasma optical emission spectroscopy (ICP-OES). The plasma is traditionally generated by passing argon through a series of concentric quartz tubes (the ICP torch) within a helical, radio frequency (RF) induction coil. Once established, this highly-ionized argon plasma canreach temperatures as high as 10,000 K, allowing for complete atomization of the compounds within a sample and minimizing the potential for chemical interferences.

PerkinElmer's patented Flat Plate plasma technology for the Avio® Max series ICP-OES provides several advantages over traditional helical coil systems - while capable of accommodating the same sample introduction systems and achieving comparable analytical precision, Flat Plate technology achieves greater plasma robustness and stability because of its unique design, leading to less sample loss, greater analytical signal, lower argon consumption, and less maintenance.

Read more about the benefits of Flat Plate plasma technology - download the technical note.

PDF 739 KB
Multicomponent Spectral Fitting on the Avio Max Series ICP-OES

Baseline and interfering element correction (IEC) are used with ICP optical emission spectrometry to correct analytical signals for contributions from the plasma, the matrix or elements other than the analyte. If the contributions from these components are not corrected accurately, the analytical result will be erroneous. Yet both correction techniques rely on interpolated or extrapolated correction factors. Although the two techniques can improve performance with some types of samples, they are not universally applicable.

For greater accuracy, using a full segment of the spectrum around the analyte wavelength is preferred to using just one or two points. To address this, PerkinElmer developed Multicomponent Spectral Fitting (MSF), a standard feature on the Avio® Max series ICP-OES instruments. MSF can significantly improve your analytical results – detection limits, accuracy, and precision.

Learn more about Multicomponent Spectral Fitting on the Avio Max series ICP-OES – download this technical note.

PDF 287 KB
The Avio 220 Max ICP-OES: A Unique Double-Monochromator Optical System

PerkinElmer's Avio® 220 Max ICP-OES delivers outstanding analytical performance thanks to the combination of its double-monochromator optical system and a range of other proprietary technologies that are part of this unique hybrid simultaneous ICP-OES solution.

Read more about the Avio 220 Max’s novel optical system, download this technical note.

PDF 706 KB
Vertical Dual View on the Avio Max Series ICP-OES

The Avio® Max series ICP-OES incorporates a vertically oriented plasma with complete dual-viewing optics under computer and software control. Its dual view technology optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength. Any wavelength can be used in the radial, axial, or mixed viewing modes in a single method without sacrificing quality, truly offering the best of both worlds.

Read more about the benefits of dual view technology on the Avio Max series vertical plasma ICP-OES spectrometers – download the technical note.

PDF 1 MB