A single reflection ATR accessory designed for the analysis of highly absorbing solid, semi-liquid and liquid samples. Easily changeable crystal plate design enables analysis of a broad spectrum of sample types while ensuring constant sampling pathlength.
The 10Spec™ Specular Reflectance Accessory is recommended for measuring the reflectivity of glass per the ASTM Standard E1585-93. It is compatible with the Spectrum One/100/400/65 and Spectrum 3/Frontier spectrometers.
The 80Spec Grazing Angle Specular Reflectance Accessory has a fixed 80° degree angle of incidence, a gold-coated alignment mirror, dual polarizer mount, and a base plate that fits all FTIR spectrometers. Three Sample Mask ( 2, 5/8, and 3/8 inch) are also available, but not included with this accessory.
The VeeMAX™ II is a high throughput, variable angle specular reflectance accessory with an an incident angle range of 30° to 80°. This accessory ships with three masks, an alignment mirror, a purge tube kit, four purge rings, and a user guide.
The Replacement OilExpress Flowcell has a 0.1 mm path length and two ports. This kit comes complete with a mount, two zinc selenide windows (one grooved), and a wedged spacer.
The KBr Window Assembly includes a parylene-coated potassum bromide window and assorted assembly components. This window is easily assembled by the customer and replaces the compartment window on the Spectrum One/100 and Frontier Optica.
The Mid-IR Source Lamp is a replacement source lamp for the Spectrum One/100/400/65 and Spectrum 3/Frontier spectrometers. This lamp includes a Source Element Accessory and a Fixed Source Mirror Replicator. With this part number, you can order a replacement or spare lamp.
This Powder Press is for use with the PerkinElmer Premium HATR Accessory to allow for the compacting of soft powder samples to prepare for analysis by HATR. With this part number, the press can be ordered as a replacement or spare part.
The MIRacle™ HATR Ge Top Plate is a single reflection, horizontal ATR plate. It is an optional configuration for the MIRacle Single Reflection ATR Accessory. This top plate has a germanium (Ge) crystal which is ideal for the analysis of carbon-filled or rubber sample materials as well as other general purpose ATR applications.
Sort by
1-25 of 44 Resource Library
In this application, the quantitative analysis of formaldehyde was successfully executed using the LAMBDA 265 UV/Vis spectrophotometer and Merck Spectroquant formaldehyde cell test kit. Principle Formaldehyde reacts with chromotropic acid in sulphuric solution to form a violet dye which can be detec ...
One of the most challenging analytical problems with increasing importance is the possibility to analyze soil polluted by the dispersion of organic fluids which sometimes features particularly high boiling points. The current techniques used solvent extraction and headspace chromatographic analysis, ...
This note describes the test method for the quantitative analysis of aerosol oil and liquid oil typically present in the air discharged from compressors and compressed air systems. The method is rapid, sensitive and cost effective and shows the FT-IR can be an effective tool for the monitoring of oi ...
Inductively coupled plasma optical emission spectroscopy (ICP-OES) is a commonly used technique for the determination of trace elements in metallurgical matrices due to its ability to handle high levels of dissolved solids without the need for special sample introduction components or matrix separat ...
Quantification methods for total protein are among the longest-established fundamental and important experiments of bioscience. UV/Vis Spectrophotometry is widely used for the determination of protein. This application note describes a typical protein method, the Bradford method. Data is rapidly acq ...
Increasing demands for efficiency, productivity, data quality, and profitability pose ongoing challenges for lubricant testing laboratories, like yours, performing new lubricant or in-service oil analyses. Whether you need to achieve quick turnaround times, minimize downtime, or maximize lab efficie ...
A typical FT-IR spectrometer will scan down to the long wavelength limit of approximately 400 cm-1 limited by the optical components such as the beamsplitter and detector which contain potassium bromide (KBr). However, there are a growing number of applications where the materials of interest exhibi ...
Chromium (VI) ions react with diphenylcarbazide in weakly phosphoric solution. The product, diphenylcarbazone, is a red-violet complex which can be detected photometrically at 550 nm. The chromate cell test kit is suitable for the concentration range of 0.11 – 4.46 mg/L chromate allowing the concent ...
Spectroscopic analysis of glass used in both construction and the automotive industry is required to determine several very important parameters such as emissivity of glass to investigate their energy-saving capability. These measurements are carried out in the Mid- and Far-infrared regions. Infrare ...
Biodiesel is seldom used neat (B100), typically being blended with fossil diesel at ratios from 5% v/v (B5) to 30% v/v (B30). Verifying the FAME content of diesel-fuel blends is an important aspect of quality control and auditing of blending and distribution operations. Because FAME has a strong inf ...
The combination of Thermogravimetric Analysis with Infrared Spectroscopy (TG-IR) is the most common type of evolved gas analysis. Thermogravimetric Analysis (TGA) accurately measures the percentage weight loss of a sample as a function of temperature, but does not provide any information regarding t ...
Pyrethroids are a type of synthetic insecticides that work by attacking arthropod insects’ nervous system, with a knockdown and cidal effect that is up to 100 times higher than that of older generation insecticides, such as organochlorine (OC), organophosphorous (OP) and carbamate pesticides. Pyreth ...
TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...
Diesel exhaust fluid (DEF), alternatively called AUS 32 and marketed as AdBlue is a diesel fuel additive that is stored separately from the car’s fuel tank. To comply with Euro 6 regulations, diesel cars use a Selective Catalytic Reduction (SCR) catalyst to inject AdBlue into the exhaust. When added ...
Crude Palm Oil (CPO) is a raw material used in the production of margarine and other vegetable oil based food products. CPO is traded and there are quality specifications based on free fatty acids (FFAs) as well as moisture and impurities. Margarine manufacturers also want to assess the CPO's ‘fitne ...
The Avio® 220 Max, the industry's only hybrid simultaneous ICP-OES, is a robust and matrix-tolerant system with plug-and-play performance taking you from cold start to analysis in just 10 minutes – ideal for labs with low-to-mid throughput requirements. The instrument’s performance is further optimi ...
When handling and processing linseed, it is important to have accurate information on its composition. Moisture, oil, and protein levels determine its value and how to use and process it. The DA 7250 can perform a multicomponent analysis in only six seconds with no sample preparation required. ...
Historical manuscripts are subject to deterioration due to aging processes under different storage and handling conditions. There can be physical, chemical and biological factors with different impact on papers and parchments or inks and dyes. Optical methods are preferred for the evaluation of hist ...
Infrared Spectroscopy has become a ubiquitous tool in the analysis of pharmaceutical raw materials, with both Mid- and Near-infrared spectroscopy functioning as commonplace techniques for the investigation of both excipients and active pharmaceutical ingredients (APIs). Near-infrared spectroscopy is ...
The PerkinElmer Spectrum OilExpress oil condition monitoring system provides a complete solution for laboratories conducting high-throughput used oil analysis. The proven performance and reliability of the syringe-pump-based autosampler and Spectrum 100 FT-IR spectrometer ensure quality spectral dat ...
Clinical chemistry uses chemical processes to measure levels of chemical components in the blood. It is very useful for the early diagnostic of disease and for monitoring organ function. The most common specimens used in clinical chemistry are blood and urine and this application note shows the comm ...
The data shows the suitability of the LAMBDA 265 for producing rapid, high-quality spectra. It also shows that the instrument is able to measure the higher nanoparticle sizes, even though these scatter light to a greater extent due to the increased particle size and also settle out more quickly.
PVDF (Polyvinylidene fluoride), along with other polymers such as SBR and PTFE, is commonly used as a binder in the anode of lithium-ion batteries due to its electrochemical and chemical stability, and high adhesion to the current collector. Understanding both the chemical composition and thermal be ...
Aluminium salts such as potassium aluminium sulphate, aluminium phosphate and aluminium oxyhydroxide have been extensively used as adjuvants in licensed vaccines. As active ingredients, quantification of aluminium salts in vaccine formulations is required during the manufacturing process. Determinat ...
Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are se ...