PerkinElmer

Sample Introduction Systems

OF

Accurate, repeatable results begin with flawless sample introduction. That's why we invest heavily in testing and validating our sample introduction accessories – to ensure you get the best possible results on time, every time, throughout the lifetime of your instrument. We offer a wide range of sample introduction systems for your analytical instrumentation, including:

  • UV sample introduction systems
  • IR sample introduction systems
  • Headspace sample introduction systems
  • And more

Products & Services (102)
Filters:
Product Type
  • Accessories (86)
  • Consumables (15)
  • Service Parts (1)
Product Brand Name
  • Clarus (1)
  • Spectrum Two N (1)
Material
  • Arsnic/Selenide/Germanium (1)
  • Diamond (1 Reflection) (1)
  • Diamond/ZnSe (1 Reflection) (3)
  • Diamond/ZnSe (3 Reflection) (2)
  • Diamond/ZnSe (9 Reflection) (3)
  • Ge (2)
  • Ge (1 Reflection) (2)
  • Germanium (8)
  • KRS-5 (1 Reflection) (2)
  • Lithium Tantalate (LiTaO3) (1)
  • Thallium Bromide (3)
  • Zinc Selenide (19)
  • ZnSe (1)
Model Compatible With
  • Avio 200 (1)
  • Avio 500 (2)
  • Frontier (5)
  • LAMBDA (9)
  • LS (2)
  • NIRA II (3)
  • NIRM (3)
  • Spectrum (35)
  • Spectrum 100 (7)
  • Spectrum 3 (2)
  • Spectrum 400 (7)
  • Spectrum 65 (6)
  • Spectrum GX (1)
  • Spectrum One (8)
  • Spectrum One/100/400/65/Frontier (1)
  • Spectrum Two (1)
Product Group
  • ATR Accessory (1)
  • ATR Pressure Arm (1)
  • Depolarizers & Accessories (6)
  • Desolvation Accessory (1)
  • Diffuse Reflectance Accessory (2)
  • Fiber Optic Accessories (1)
  • Fixed Angle Accessory (1)
  • HATR Accessory (9)
  • Heatable Transmission Accessory (1)
  • Imaging Accessory (1)
  • IR Specular Reflectance Set (1)
  • Miracle Accessory (3)
  • NIR Accessory (3)
  • NIRM Accessory (1)
  • Optical Bench (4)
  • Polarization Accessory (1)
  • Powder Press (1)
  • Sample Holder Supplies (1)
  • Sample Introduction Module (6)
  • Sampling System (3)
  • Specialty Accessories (1)
  • Specialty Accessories & Supplies (3)
  • Top Plate Accessory (3)
  • Top Plates (19)
  • UATR Accessory (4)
  • UATR Polarization Accessory (2)
  • Variable-Angle Accessory (1)
  • Volatiles Cover (1)
Technology Type
  • ATR (11)
  • Diffuse Reflectance (7)
  • Fluorescence (FLR) (2)
  • FT-IR (1)
  • ICP-OES (3)
  • IR (45)
  • TEA (1)
  • UV/VIS (9)
Type
  • Peristaltic Pump Tubing (1)

Sort by

1-25 of 102 Products & Services

  • Sample Holder for TGA 6

    Ceramic Sample Cup Holder

    The Ceramic Sample Cup Holder is a sample handling tool that comes standard in the TGA 4000 Non-AutoSampler Accessory Kit (N5200046). This tool can also be used when working with ceramic sample holders and the following analyzers: TGA 6/TGA 4000/STA 6000. Qty. 1

    List Price : 405.00 USD
  • Spectrum Two N HTM

    Heatable Transmission Module (HTM) for Spectrum Two Platform

    The Heatable Transmission Module (HTM) for the Spectrum Two platform (including both the Spectrum Two FT-IR and Spectrum Two N FT-NIR) allows for easy elevated temperature measurements on samples in the Mid-IR or Near-IR regions of the spectrum, the module accepting fixed pathlength sealed.
  • N0810854

    MP2 Peripump Valve Two Assembly for Avio 500

    Valve two Driver Assembly for Avio 500 MP2 Peripump (includes mounting screws): For upgrading single valve DXi to dual valve DXi for prepFAST
    List Price : 5400.00 USD
  • Spectrum Two N with NIRM accessory and optional Sample Vial Holder

    Sample Vial Holder

    The Sample Vial Holder for use with the Near-Infrared Reflectance Module (NIRM) and Near Infrared Reflectance Accessory (NIRA II) securely holds and aligns vials on the accessory window.
  • Peltier Temperature Controller (without Cell) for LAMBDA 265

    Peltier Temperature Controller (without Cell) for LAMBDA 465

    Comes with internal liquid cooling system and N2 purge gas capability, magnetic stirrer control, and emergency power off switch.
  • N0790954

    MP2 Peripump for Avio 200

    Mp2 Peripump For Avio 200
    List Price : 10400.00 USD
  • N0810853

    MP2 Peripump Valve One Assembly for Avio 500

    Valve one driver Assembly for Avio 500 MP2 Peripump (includes mounting screws) for upgrading DXi pump module
    List Price : 5400.00 USD
  • Fiber Coupling Module-Req./ Inc.* for LAMBDA 465

    Fiber Coupling Module-Req./ Inc.* for LAMBDA 465

    Used for measuring liquid samples; intended for hazardous samples. Includes N4101048, a transmission dip probe and a 10 mm pathlength tip. Easy to clean.
  • Spectrum Two N with NIRM accessory and optional Sample Spinner

    60 mm Sample Spinner

    The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
  • Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

    Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

    The Near Infrared Reflectance Module for the Spectrum Two N FT-NIR provides a convenient and sensitive method for analyzing opaque or highly scattering solid samples such as pharmaceuticals, food products, soap powders, coal, clay, soil, paper, painted surfaces, polymer foam, and catalysts.
  • Water Jacketed Automatic Referencing Stage for LAMBDA 465

    Water Jacketed Automatic Referencing Stage for LAMBDA 465

    Accommodates any standard 10 mm cells 2-Position for reference and sample. Unique accessory provides long term stability for monitoring kinetics reactions. Use recirculating liquid to control the temperature of a sample and reference solution for simultaneous analysis.
  • Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

    Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

    Fiber Optic Probe Module Only for L365. When combined with Fiber Optic Probe it can be used for measuring liquid samples; intended for hazardous samples.
  • PerkinElmer

    Diffuse Reflectance Accessory for LAMBDA 465

    Used for measuring the diffuse reflectance (SCE) and color analysis for solid and powder samples. It has a spectral range of 270~1000 nm (UV and Visible), and a port size of 10.00 and 5.00 mm (selectable). Included is a Xenon Lamp (150W), and a White Standard (1 each).
  • Spectrum Two N with NIRM accessory and optional Sample Spinner

    100 mm Sample Spinner

    The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
  • 8-Position Multicell Holder for LAMBDA 365

    8-Position Multicell Holder for LAMBDA 365

    Accommodates any standard 10 mm cells; up to 8 samples.
  • HTS NexION ICP-MS

    High Throughput System for NexION ICP Mass Spectrometers

    PerkinElmer’s High Throughput System (HTS) is a novel high-volume sample introduction module for ultrafast trace-metal analysis, dramatically reducing laboratory overheads and cost of analysis. Integrating seamlessly with the NexION® ICP-MS (1000 and 2000B/C) and Syngistix software, this system delivers up to five times faster sample analysis without compromising detection limits, accuracy or repeatability.
  • PerkinElmer

    Value HATR Trough Top Plate - KRS-5

    This Value HATR Trough Top Plate is a stainless steel plate featuring a thallium bromide (KRS-5) crystal. It can be used with the PerkinElmer Value HATR accessories that are compatible with the Spectrum Two and Spectrum 3/Frontier spectrometers.

  • PerkinElmer

    Spectrum Two Base Plate

    The Spectrum Two Base Plate enables a variety of sampling accessories to interface properly in this spectrometer's sample compartment. With this part number, you can order a replacement or spare plate.
    List Price : 300.00 USD
  • PerkinElmer

    Value HATR Variable Pressure Clamp Assembly - Replacement

    The Variable Pressure Clamp Assembly is for use with the PerkinElmer Value HATR Accessory. It ensures good contact between the sample and the crystal during analysis by HATR. It can be purchased separately as a replacement or spare clamp, using this part number.

  • HTS Avio 500 ICP-OES

    High Throughput System for Avio ICP-OES

    PerkinElmer's High Throughput System (HTS) is a uniquely designed flow injection sample introduction module that integrates seamlessly with the Avio® series of ICP optical emission spectrometers (ICP-OES) to dramatically reduce sample-to-sample analysis time, thereby improving throughput while maintaining operation simplicity. The HTS maximizes productivity by significantly reducing the time required for the sample uptake, stabilization, and washout.
  • Frontier UATR Diamond/ZnSe with 1 Reflection Top-Plate and Pressure Arm for the Frontier

    UATR Accessory for Frontier

    The Universal ATR is an excellent general accessory for the analysis of solids and liquids, producing high quality spectra through the use of a pressure arm, allowing for good contact of the sample with the diamond/ZnSe crystal. The Spectrum 3/Frontier system ships basic transmission mode functionality (sample holder) as standard. There is a wide range of PerkinElmer sampling accessories available for the Spectrum 3/Frontier instruments. For the widest range of MIR applications, we recommend the Spectrum 3/Frontier UATR Accessory.

     

  • PerkinElmer

    Value HATR Flat Top Plate - KRS-5

    This Value HATR Flat Top Plate is a stainless steel plate featuring a thallium bromide (KRS-5) crystal. It can be used with the PerkinElmer Value HATR accessories that are compatible with the Spectrum Two and Spectrum 3/Frontier spectrometers.

  • PerkinElmer

    UATR Top Plate - ZnSe, 9-Reflection

    The UATR Top Plate is an optional 9-reflection top plate with a diamond/zinc selenide crystal. With this part number, you can order this top plate as a replacement or spare.

    List Price : 5400.00 USD
  • *Fiber Optic Probe for LAMBDA 465

    Fiber Optic Probe for LAMBDA 465

    Replacement Fiber Optic Probe and a 10 mm pathlength tip for the N4104012 or N4101013 Fiber Optic Probe Modules.
  • PerkinElmer

    Premium HATR Flat Top Plate, ZnSe, 45°, Extended Life

    The Premium HATR Flat Top Plate features a zinc selenide (ZnSe) crystal set at a 45° angle, allowing for simple sampling of solids, polymer films, and powders. This crystal has a special protective coating to extend its lifetime. It is used with PerkinElmer Premium HATR accessories that are compatible with the Spectrum One/100/400/65 and Spectrum 3/Frontier spectrometers.

  • Jump to:
Business Insights (2)
Filters:

Sort by

1-2 of 2 Business Insights