Spectrum Two FT-IR Spectrometer with LiTaO3 Detector | PerkinElmer
PerkinElmer
check quantity

Spectrum Two FT-IR Spectrometer

Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications. Choose the Spectrum Two + that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity.

Part Number
Model Name
L160000A
Spectrum Two FT-IR Spectrometer (LiTaO3 Detector)
more
L160000F
Spectrum Two FT-IR Spectrometer (DTGS Detector)
more
L1390021
Spectrum Two N FT-NIR Spectrometer (LiTaO3 Detector)
more
L1390023
Spectrum Two N FT-NIR Spectrometer (InGaAs Detector)
more
L160000T
Spectrum Two Pharmaceutical System
more
L160000W
Spectrum Two Nutraceutical & TCM System
more
L160000Q
Spectrum Two In-Service Lubricant Analysis System
more
L160000S
Spectrum Two Environmental Hydrocarbon Analysis System
more
L160000U
Spectrum Two Educational System
more
L160000R
Spectrum Two IR Biodiesel Analysis System
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

IR for Everyone, Everywhere

Spectrum Two breaks ground in operational simplicity, combining superb performance with low maintenance design. True laboratory performance IR for everyday analysis is possible for everyone, everywhere.

The Spectrum Two is suitable for a wide range of applications and can be configured to your needs regarding the level of performance desired to meet the demands of your daily IR analyses. See the configurations table below for all available instrument options.

Spectrum Two FT-IR spectrometers feature:

  • Standard, high-performance, room-temperature LiTaO3 (lithium tantalate) MIR detector with a SNR of 9,300:1
  • Optional temperature-stabilized, high-performance DTGS (deuterated triglycine sulfate) MIR detector with a SNR of 14,500:1. Ideal for low-light, high throughput applications
  • Standard optical system with KBr windows for data collection over a spectral range of 8,300 – 350 cm-1 at a best resolution of 0.5 cm-1
  • Optional ZnSe windows, for use in exceptionally humid environments for data collection over a spectral range of 6,000-550 cm-1
  • Standard AVC with optional APV/AVI configuration

Additional features that allow for consistent performance of this system include:

  • Dynascan interferometer – Fixed mirror-pair interferometer design does not require dynamic alignment to compensate for errors.
  • OpticsGuard technology – Unique humidity shield design protects Spectrum Two from environmental effects, allowing it to be used in more challenging conditions. Our long-life desiccant ensures maximum instrument uptime, regardless of where your analysis takes place.
  • Atmospheric Vapor Compensation (AVC) – Features an advanced digital filtering algorithm designed to compensate for CO2 and H2O absorptions in real time removing the need for instrument purging.
  • Automatic Performance Verification (APV) – Optional feature comprising an integrated, fully automatic filter wheel containing traceable reference materials and software allowing for abscissa, ordinate, noise, ASTM, and USP tests to be performed.
  • Absolute Virtual Instrument (AVI) – Optional AVI standardization using gas phase methane spectra ensures instruments are accurately calibrated. Unique standardization allows data to be transferred precisely between instruments, side-by-side or in remote locations.
  • Sigma-Delta Conversion – The use of Sigma-Delta converters in the digitization of the FT-IR interferogram improves the dynamic range, reduces spectral artifacts, and increases ordinate linearity to provide accurate, reproducible results.

For Every Application

PerkinElmer recognizes that every application is different. The result is a complete solution to provide the fastest assurance of the quality of your materials, regardless of the application. Some of the industry applications that the Spectrum Two is designed to accommodate include:

  • Pharmaceuticals and Nutraceuticals
  • In-service lubricants and fuels
  • Environmental
  • Polymers
  • Academia

For these specific applications, we offer various analysis systems and application pack add-ons. Spectrum Two is designed to function with a variety of “plug-and-go” sampling accessories to enhance the versatility of the instrument. We offer a range of UATR, HATR, Diffuse Reflectance, and Specular Reflectance accessories for use with the Spectrum Two system.

Results Matter

The Spectrum 10 software supplied with your instrument enables you to control the instrument and to manipulate the spectra that you collect. The spectrometers can operate in ratio, single-beam, or interferogram mode.

From material and contaminant identification to quantitative analysis, the comprehensive Spectrum 10 software suite allows you to focus on what matters most – results. Designed for busy industrial or academic laboratories, this comprehensive FT-IR software package facilitates data collection, processing, and results generation. The software enables users without scientific training to generate infrared spectra from a sample and validate them against reference spectra in minutes, or even seconds. For regulated industries that demand secure IR quality testing, Spectrum 10 ES software is available. Spectrum 10 ES includes the comprehensive features of Spectrum 10 and encompasses user access control, audit trailing, data security, and data integrity to ensure secure analyses to meet the technical demands of 21 CFR Part 11 compliance.

Collaborate From The Cloud

Spectrum 10 software with NetPlus cloud connectivity offers new sharing and collaborative tools that allow you to access data from any device, any time, from anywhere, and selectively distribute and download data and methods through the built-in publishing tool.

  • Securely share data, calibrations, methods, and reports
  • Collaborate by accessing IR data from any device, whenever and wherever it’s needed

IR Ready to Go

The compact and robust design of the Spectrum Two means that the instrument can be easily transferred between environments. The simple user-installation and fast warm-up time means that the instrument can be set up quickly. The wide range of sampling accessories available can help your analysis move out of the laboratory. With optional features such as wireless connectivity to enable portable PC control, or the Portability Pack featuring a carrying case, battery pack, and 12V car auxiliary port adaptor, the Spectrum Two is ready to go where you go.

Specifications

21 CFR Part 11 Compatible Yes
Depth 30.0 cm
Detector Type LiTaO3
Height 21.0 cm
Model Name Spectrum Two FT-IR Spectrometer (LiTaO3 Detector)
Operating Range 5 - 45 °C
Portable Yes
Product Brand Name Spectrum Two
Warranty 1 year
Wave Length 8
Wave Length Range 8,300 – 350 cm-1
Weight 13.0 kg
Width 45.0 cm

Configurations

Detector Type Windows APV/AVI? Software Part Number
LiTaO3 KBr No Spectrum 10 L160000A
LiTaO3 KBr No Spectrum 10 ES L160000I
LiTaO3 KBr Yes Spectrum 10 L160000B
LiTaO3 KBr Yes Spectrum 10 ES L160000J
LiTaO3 ZnSe No Spectrum 10 L160000C
LiTaO3 ZnSe No Spectrum 10 ES L160000K
LiTaO3 ZnSe Yes Spectrum 10 L160000D
LiTaO3 ZnSe Yes Spectrum 10 ES L160000L
Resources, Events & More
  • All

Application Note

Analysis of Bioethanol Impurities with the Spectrum Two FT-IR Spectrometer

The intensifying global emphasis on developing sustainable fuel supplies has led to increasing use of fuels derived from biological sources. In this note we show that the Spectrum Two™ FT-IR spectrometer (Figure 1) can be used to develop a quantitative method with sufficient sensitivity to meet the ...

PDF 814 KB
Analysis of in-Service Greases with PerkinElmer Spectrum Two FTIR and Specac Pearl Liquid Transmission Accessory

Condition monitoring of lubricants with FTIR spectroscopy is a useful diagnostic tool that can help us to determine whether a lubricant is fit for purpose during its service life. However, analyzing lubricating grease is different to other less viscous lubricants due to the physical characteristics ...

PDF 839 KB
Biodiesel Concentration Measurements Using Attenuated Total Reflectance (ATR)

Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are se ...

PDF 1 MB
Confirmation of the Presence of Styrene Butadiene Resin (SBR) Polymer in Drywall Primer

Building specifications for the interior wall finish require the application of a vapor barrier rated primer followed by the normal decorative paint/top coat. Some architects and developers of condominium housing projects have started using a rated vapor barrier primer/paint to replace the tradition ...

PDF 1 MB
Determination of DBPC and DBP in Transformer Insulating Oil According to ASTM D2668 and IEC 60666

Transformer insulating oil is often exposed to high temperatures due to the high voltage electrical applications for which it is commonly used. As a result, insulating oil degrades over time, reducing its ability to act as an insulator and possibly leading to equipment failure. 2,6-di-tert-butyl-p-c ...

PDF 1 MB
Determination of Oil and Grease in Water with a Mid-Infrared Spectrometer

The concentration of dispersed oil and grease is an important parameter for water quality and safety. Oil and grease in water can cause surface films and shoreline deposits leading to environmental degradation, and can induce human health risks when discharge.

PDF 2 MB
Determination of THC and CBD in Cannabis Flower

This work shows an on-site, rapid and low-cost technique for the accurate measurement of flower potency. FT-NIR spectroscopy provides rich information regarding the chemical composition of cannabis flower. When combined with chemometrics, the FT-NIR offers unparalleled speed and simplicity that cann ...

PDF 1 MB
Determining the Source Oil of Biodiesel with Infrared Spectroscopy

Infrared spectroscopy is particularly suitable for the identification of materials, even when the differences between the materials are subtle variations in complex mixtures. In this note we demonstrate that biodiesel from several common feedstocks can be distinguished on the basis of absorption ban ...

PDF 176 KB
Diamond ATR and Calibration Transfer for Biodiesel-Blend Analysis by ASTM D7371

Biodiesel is seldom used neat (B100), typically being blended with fossil diesel at ratios from 5% v/v (B5) to 30% v/v (B30). Verifying the FAME content of diesel-fuel blends is an important aspect of quality control and auditing of blending and distribution operations. Because FAME has a strong inf ...

PDF 754 KB
Effects of Ionizable and Non-ionizable Excipients on Lyophilized RNA Formulations Using FTIR-ATR Technology

There are ongoing attempts to improve the storage stability of mRNA vaccines by converting them to solid forms using various drying methods. Lyophilization is one such method and has the potential to stabilize mRNA, but there are few reports that describe the interactions of lyophilized mRNA with ex ...

PDF 1 MB
FTIR Analysis of Hydrocarbon Contamination in Diesel Exhaust Fluid (DEF)

DEF is a colorless liquid which is beneficial in the reduction of nitrogen oxide (NOx) emissions from diesel engines. The Selective Catalytic Reduction (SCR) system injects the DEF through a catalyst, converting the harmful nitrogen oxides into nitrogen, water, and carbon dioxide. Problems can occur ...

PDF 1 MB
Finding and Preventing PP Contamination Using FT-IR in Post-Consumer Recycled Plastic (HDPE)

High-density polyethylene (HDPE) is a commonly recycled plastic, notably from plastic drinking bottles. Recycled applications of HDPE are many and various including new packaging and textile fibres. But it is especially valued in automotive applications including fuel tanks, wiring, cables, pipes an ...

PDF 593 KB
Identification of Drugs of Abuse Using Infrared Spectroscopy

There are a wide variety of characterization techniques which may be used to identify drugs of abuse, including infrared spectroscopy, Raman spectroscopy, mass spectrometry, gas chromatography, x-ray diffractometry, immunoassays and urine dipstick tests. FT-IR spectroscopy provides one of the best s ...

PDF 162 KB
Optimization of the Decarboxylation Reaction in Cannabis Extract

Most cannabis extraction processes, independent of solvent or instrument choice, undergo a decarboxylation step whereby the carboxylic acid functional group is removed from the cannabinoids. The PerkinElmer Spectrum Two with the UATR accessory allows for the simple and rapid determination of cannabi ...

PDF 812 KB
Plasticizer Characterization by TG-IR Application Note

Thermogravimetric analysis (TGA) is a common technique that is used to study the weight loss during heating. It can tell you the percentage of weight loss quantitatively and accurately. But TGA alone will not tell you anything about the chemical components of the evolved off gas. The hyphenation bet ...

PDF 1022 KB
Polymer Recycling Compendium

This compendium provides example data and interpretations for the seven codes of recyclable polymers. DSC and TGA raw data files are provided so that the user can easily overlay their data with the expected results for new unprocessed plastics. This allows for a confirmation of identity and assists ...

PDF 1 MB
Portable Quantitative Biodiesel Analysis Using the Spectrum Two FTIR as per ASTM D7371

Biodiesel, also referred to as fatty acid methyl ester (FAME), is a renewable and biodegradable fuel manufactured from vegetable oils, animal fats as well as recycled cooking greases and oils. A quick and accurate test method is highly desirable as quality control for producers, blenders and distrib ...

PDF 1 MB
Rapid Characterization of Multiple Regions of Interest in a Sample Using Automated IR Microscopy

Infrared microscopy is a well-established analytical technique for the measurement and identification of small samples down to a few micrometers in size. It is used extensively in the polymer, pharmaceutical, chemical, food, and electronics industries, to name a few, often identifying small contamin ...

PDF 286 KB
Rapid Quantitative Determination of Free Silica in Dust by Infrared Spectroscopy

Free silica in dust is the main cause of silicosis, hence analyzing the content of free silica in dust is an important part of occupational health monitoring. The standard for measurement includes several methods for determination of free silica, including pyrophosphoric acid method, infrared spectr ...

PDF 1 MB
Raw Material Identification in the Semiconductor Industry

More than 400 chemical products are used in semiconductor plants. There are over 200 liquids and 25 solids. Approximately 170 pure chemical ingredients are used. A third of products contain one of the following ingredients; propylene glycol monomethyl ether acetate (PGMEA), cyclohexanone and propyle ...

PDF 932 KB
Top QA/QC Tools for Pharma

Pharmaceutical manufacturing Quality Assurance and Quality Control teams face many challenges including GMP compliance and data integrity, qualification of instrument performance, use of high quality consumables, data management, use of Informatics and Quality by Design principles. To help navigate ...

PDF 9 MB
Use of FTIR to Characterize and Monitor the Curing of Sealants

Sealants have a wide range of commercial and industrial applications often requiring highly specialized formulations for the different environments they may be used in, such as extreme temperature environments. FTIR (Fourier-Transform Infrared) spectroscopy utilizing the Attenuated Total Reflectance ...

PDF 1 MB

Article

A Comparison of Standard Test Methods for Determining FAME in Diesel by Infrared Spectroscopy

As the importance of sustainable energy production increases, so too does the global commitment to using fuels from renewable biological sources. Biodiesel is one such renewable fuel. Consisting of fatty acids of methyl esters (FAME), it is produced from plant crops by transesterification – a reacti ...

PDF 2 MB
Harnessing the Power of FT-IR to Guarantee Water Safety

This note explores more environmentally-friendly approaches to the use of IR spectroscopy for detecting and quantifying hydrocarbon contamination.

PDF 3 MB
Identification and Quantification of Microplastics in Wastewater Using Focal Plane Array-Based Reflectance Micro-FT-IR Imaging Article

This article describes methods for identifying and quantifying microplastics within organic-rich wastewater samples.

PDF 3 MB

Brochure

PerkinElmer Frontier FT-IR, NIR and FIR Spectroscopy Brochure

Choose the PerkinElmer Frontier™ range of near-, mid- and far-IR Fourier Transform spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. And with au ...

PDF 12 MB
Spotlight 150i 200i FT-IR Microscope Systems Brochure

This brochure describes the Spotlight 150i and Spotligh 200i FT-IR Microscope System technology.

PDF 1 MB

Case Chemicals Testing Solutions

Case Chemicals Testing Solutions

Field Application Report

Analyzing Recycled Polyethylene Resin for Polypropylene Contamination Using FTIR

FAR, Field Application Report, Recycled Polyethylene Resin, Polypropylene Contamination, High-density polyethylene, HDPE, PP, PE, Fourier Transform Infrared Spectroscopy, FT-IR, Spectrum Two, ATR, Spectrum Quant

PDF 494 KB

Flyer

Simplified In-Service Lubricant Analysis for OilExpress 4 Ensemble Flyer

Your in-service lubricant testing lab demands high productivity and reliable results. Does your lab measure up to today’s standards with: Effortless high-throughput oil analysis Reliability and cost efficiency operations for highly automated, rapid, reliable oil condition monitoring results Recogniz ...

PDF 955 KB

Guide

Battery Analysis Guide

This guide offers an overview of analyses required throughout the battery value chain - learn about innovative analytical solutions for testing every part of the battery, including the anode, cathode, binder, separator, and electrolyte. See the value in data generated from a variety of applications ...

PDF 2 MB
Evolved Gas Analysis - Hyphenated Technology Guide

The needs for polymer, pharmaceutical, chemicals, food and beverage, and environmental analyses are constantly changing due to innovation demands and regulation changes. Evolved Gas Analysis (EGA) solutions combine multiple analytical technologies to empower speed and advanced information acquisitio ...

PDF 3 MB
Hyphenated Technology Compendium of 21 Application Notes

PerkinElmer’s hyphenated solutions couple two or more instruments to greatly increase the power of analyses and save precious time by acquiring more information from a single run. The TGA 8000™ and STA systems coupled with FT-IR, MS, and/or GC/MS instruments represent the industry’s most complete an ...

PDF 7 MB

Poster

Advanced Solutions for Polymers and Plastics

This poster lays out our whole material characterization range for the analysis of polymers and plastics. Find ideal techniques and instruments at each stage in the polymer manufacturing process: Resin Development - Resin Manufacture - Compound Development - Compound Manufacture - Product Forming - ...

PDF 2 MB
Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...

PDF 1 MB

Product Note

Polymer Recycling Package

The PerkinElmer Polymer Recycling Package makes use of the most commonly-used techniques for material characterization and additionally supports Plastic Identification Codes (PIC), used worldwide for packaging applications. When you download this Product Note - known as the PerkinElmer Polymer Recyc ...

PDF 2 MB
Spectrum Touch Software Product Note

Using spectrum touch software and predefined operating procedures in IR and NIR analyses can help fulfill regulatory compliance requirements, decrease error rate and enable better communication of effective analysis with stakeholders

PDF 1 MB
TIBCO Spotfire Software for IR Instrumentation Product Note

Product note dscribes TIBCO Spotfire for IR Instrumentation software product from PerkinElmer that creates powerful visualizations to ensure the quality and consistency of your results-every time.

PDF 730 KB

Regulatory Compliance Certification

Product Certificate - Spectrum Two

Product Certificate for the Spectrum Two

PDF 98 KB

Technical Note

Applications and Design of a Micro-ATR Objective

Attenuated total reflectance (ATR) techniques are well established in FT-IR spectroscopy for the direct measurement of solid and liquid samples without sample preparation. The technique requires good contact between the sample and a crystal made from a material which transmits IR radiation and has a ...

PDF 600 KB
Obtaining Optimum Reproducibility for FT-IR Measurements in ZnSe Liquid Transmission Cells

Zinc selenide is a very useful material for infrared sampling optics, since it is transparent over most of the mid-infrared range, fairly hard and durable and resistant to water and most chemicals. Consequently it is widely used for attenuated total reflectance (ATR) and liquid transmission cells. ...

PDF 235 KB

White Paper

CASE Chemicals: Trends, Innovations, and Challenges

The specialty chemical category referred to as CASE – coatings, adhesives, sealants, and elastomers – are essential materials throughout industrial and consumer product manufacturing. CASE provide advanced functional characteristics – e.g. performance, protection, operation, strength, and durability ...

PDF 293 KB
Data Integrity – Spectrum 10 Enhanced Security (ES) Software for Infrared Spectroscopy

The FDA defines data integrity as “completeness, consistency, and accuracy of data. Complete, consistent, and accurate data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA)”. ALCOA itself has evolved to ALCOA Plus, which incorporates two of t ...

PDF 3 MB
Growing Concerns Over Microplastics in Water White Paper

This white paper explains the problem of microplastics in water and what are the best instruments to trace, identify, and classify microbeads in products, food, and the environment.

PDF 627 KB
Selection Criteria for Analytical Technologies that Meet Polymer Manufacture and Recycling Testing Needs

This white paper discusses what testing is required at each step in the polymer production lifecycle from R&D to manufacture to recycling. It explores the analytical technologies that will meet those testing needs, and important considerations to help you select the instrumentation that will provide ...

PDF 1 MB