NexION 1100 ICP Mass Spectrometer | PerkinElmer
PerkinElmer
check quantity

NexION 1100 ICP Mass Spectrometer

For testing labs conducting trace-elemental analyses looking for a reliable yet easy-to operate system capable of high sample throughput, the NexION® 1100 ICP-MS builds on a strong tradition of reliable, easy-to-use, low-maintenance instrumentation, now reinventing the user experience for routine ICP-MS applications.

Its unique single-analyzer, three-quad design, combined with a single gas channel (with upgrade option to multiple channels) and a modernized workflow, come together to offer simple yet effective interference removal, low maintenance, excellent stability, as well as sustainability, all in a streamlined experience – the ideal ICP-MS for day-to-day trace-elemental analyses.

Part Number N8170011
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

The NexION 1100 is a single-analyzer ICP-MS with three quad-design and a single gas channel, boasting a unique combination of proprietary technologies:

  • Proprietary three-quad design provides three stages of mass resolution:
    • Quadrupole Ion Deflector (Q0) directs ions to the Universal Cell (Q1) with varied voltages, so target ion sensitivity is maximized while unwanted masses are reduced.
    • Quadrupole Universal Cell (Q1) comes standard with one cell gas channel with upgrade option to three channels with on-the-fly gas mixing capability for Collision and Reaction modes.
    • Transmission Analyzer Quadrupole (Q2, full-sized for < 0.7 amu mass resolution) acts as a mass filter or as an ion guide to direct ions to the detector.
  • Single gas channel provides universal solution for most applications, leveraging helium only for Collision mode or helium-hydrogen mix for Collision and Reaction modes, so you can easily switch between modes without changing gas. The single gas channel can also accommodate pure reaction gases and can be upgraded to two or three channels, for even stronger interference removal capability.
  • Proprietary Extended Dynamic Range (EDR) increases linear dynamic range to 1014, allowing to run both high- and low-concentration analytes in a single analytical run, resulting in fewer re-runs.
  • Powerful All Matrix Solution (AMS) allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to support samples with up to 35% total dissolved solids.
  • Novel free-running RF Generator with proprietary LumiCoil RF load coil, especially designed for ICP-MS applications, provides accurate impedance matching to easily handle the most difficult matrices and solvents. This revolutionary combination delivers superior plasma power and stability for uncompromised performance, robustness, and reliability.
  • Low maintenance for greater uptime:
    • Triple Cone Interface and Quadrupole Ion Deflector combination deliver no maintenance beyond cones, for continual operation and improved stability.
    • 34 MHz free-running RF Generator offers trouble-free user experience – the plasma is generated by the unique LumiCoil RF load coil, which does not require water or gas cooling, so maintenance-free, eliminating need to replace plasma load coils.
  • Innovative LCD touchscreen allows you to perform critical day-to-day tasks, including hardware control, results reviews, instrument parameter diagnostics, analytics, access to embedded training videos, and more.
  • External status LED lighting provides easy visibility of state of analysis, optimizing efficiencies in the laboratory.
  • Syngistix™ for ICP-MS software v.4.0 or higher uplevels the user experience with a modern database backend for easier LIMS integration and new FastQuant Data Viewer for easier review, reprocessing and exporting.

Specifications

Depth 72.0 cm
Height 84.0 cm
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Determination of Chloride in Cathode Materials Using the NexION 1100 ICP-MS

Lithium nickel cobalt manganese oxide (LNCM) is the key cathode material for ternary lithium batteries which have a higher electric capacity and are less costly than lithium iron phosphate batteries. Chloride (Cl) is a type of impurity that may affect the efficiency and storage capacity of the batte ...

PDF 1 MB
Determination of Elemental Impurities in Lithium Battery Cathode Materials Using the NexION 1100 ICP-MS

The quality of the cathode material of a lithium ion (Li-ion) battery, especially the ratio of the primary elements and the concentrations of impurities, has great impact on its charging and discharging performance. Therefore, it is very important to prevent the introduction of impurities in the raw ...

PDF 870 KB

Application Note

Analysis of Drinking Water Using Universal Collision-Reaction Gas Technology on the NexION 1100 ICP-MS

The most significant challenge in trace element analysis of drinking water is ensuring detection capability that complies with the regulatory framework at the same time as maximizing sample throughput. The NexION® 1100 ICP-MS solves the challenges that high-throughout laboratories face using a robus ...

PDF 974 KB
Direct Determination of Rare Earth Impurities in High-Purity Gadolinium Oxide with the NexION 1100 ICP-MS

With the development of high-purity rare earth element (REE) products in many industrial fields such as the semiconductor, high-temperature superconductor and optoelectronics, the demand for purity analysis of REE products is increasing. As a result, it is critically important to be able to accurate ...

PDF 908 KB
Direct Determination of Rare Earth Impurities in High-Purity Terbium Oxide with the NexION 1100 ICP-MS

Rare earth elements (REEs) comprise a group of 17 elements that span the lanthanide series from lanthanum (La) to lutetium (Lu), including scandium and yttrium. Among these, terbium oxide (Tb4O7) is an important REE compound that has a variety of uses across modern-day technologies. Its purity is us ...

PDF 530 KB
Measurement of lodine in Drinking Water Following GB/T-5750.5-2023 Using the NexION 1100 ICP-MS

Iodine is an essential trace element for human health, but excessive or insufficient intake can cause thyroid disorders. Iodine can also be introduced into water as a disinfectant or a disinfection by-product. Therefore, iodine analysis is important to monitor the quality and safety of drinking wate ...

PDF 873 KB
Multi-Element Analysis of Drinking Water Following GB/T-5750.6-2023 Using the NexION 1100 ICP-MS

As a vital resource for human consumption, the quality of drinking water is of utmost importance. To help ensure its quality and safety, method GB/T-5750.6 specifies the procedures and requirements for analyzing metal elements and metalloids in drinking water and their source water. For each element ...

PDF 1 MB
Multi-Element Analysis of Drinking Water Following ISO 17294-2 Using the NexION 1100 ICP-MS

To help ensure the quality and safety of drinking water, the international standard method ISO 17294 outlines the analysis of elements using inductively coupled plasma mass spectrometry (ICP-MS), providing the general directions for the use of the ICP-MS technique. In comparison to other analytical ...

PDF 438 KB
Testing and Validation of Elemental Impurities in Pharmaceuticals per ICH Q3D and USP <232>/<233> with NexION 1100 ICP-MS

In 2018, the United States Pharmacopeia (USP) in General Chapters <232> and <233> updated the list of elements and maximum permissible daily exposure (PDE) values of elemental impurities in drugs, pharmaceutical substances, and raw materials. The USP is now aligned with the International Council for ...

PDF 296 KB

Brochure

NexION 1100 ICP-MS - Reinventing the Routine

Today’s busiest, highest-throughput testing labs spend a good deal of their efforts and resources running routine trace-elemental analyses that rely on everyday applications. And many of the technicians running these well-defined methods are novice users who could benefit from more simple, straightf ...

PDF 3 MB

Case Study

Electronic Board Recycling with ICP-MS and ICP-OES: Smart, Sustainable - and Successful

Camston Wrather is revolutionizing waste disposal by pioneering sustainable resource recovery, especially from printed circuit boards. Discover how partnering with PerkinElmer, they've overcome lab challenges, advancing their eco-friendly mission. This customer story highlights how they are able to ...

PDF 1 MB

Flyer

ISO 17294 Water Analyzer - Compliance Without Complexity

Built on robust, flexible technology that enables labs to comply with ISO 17294-2, PerkinElmer’s ISO 17294 Water Analyzer allows you to quickly begin analyzing drinking and surface water samples using a complete, end-to-end workflow, including instrumentation, software, consumables, validated method ...

PDF 430 KB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve their ...

PDF 587 KB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available: Atomic absorption (AA): flame and graphite furnace Inductively coupled plasma optical emission spectroscopy (ICP ...

PDF 3 MB
NexION 1100/2200 ICP-MS Preparing Your Lab

For laboratories that purchased a NexION® 1100/2200 ICP-MS system, this document provides information to assist in preparing your laboratory site for the instrument prior to delivery and installation. It is intended for laboratory and facility managers responsible for site planning and laboratory pr ...

PDF 831 KB
NexION ICP-MS Series - Superior Interference Removal, Accurate Results

Accurate, reproducible trace elemental analysis is essential to ensuring the quality and safety of our products and our environment, and the award-winning NexION® ICP-MS platform delivers that level of accuracy and repeatability through a host of unique features that provide superior interference re ...

PDF 2 MB
NexION ICP-MS Series Consumables & Supplies Guide

Whether looking for sample introduction components or standards, we have the consumables you need to keep your NexION up and running smoothly and efficiently.

PDF 1 MB

Product Note

GreenCT Cooling System – Keeping the Instrument and Planet Cool

The novel GreenCT™ cooling system is designed to provide a reliable, energy-efficient, cost-effective, and eco-friendly solution for cooling the NexION® 1100/2200 ICP-MS system, making it an ideal choice for laboratories looking to optimize their operations and lower operating costs, while reducing ...

PDF 906 KB
High Throughput System for ICP-MS and ICP-OES Product Note

Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining operation simplicity. The HTS maxi ...

PDF 1 MB
Syngistix for ICP-MS Software - Revving Up the User Experience

Syngistix™ for ICP-MS software for the NexION® ICP-MS instruments is designed to improve efficiencies in the laboratory. It features a refreshed user interface that conforms to your workflow, delivering a modern, streamlined experience based on familiar left-to-right navigation and a ribbon menu, wi ...

PDF 778 KB

Regulatory Compliance Certification

Technical Note

Advantages of a Novel Plasma Generator for the NexION 1100/2200/5000 ICP-MS Systems

Unlike other ICP-MS systems on the market that utilize conventional 40-MHz or 27-MHz commercially available generators which are typically customized and modified to work with ICP-MS instruments, the NexION® 1100/2200/5000 ICP-MS systems feature a 34-MHz frequency free-running RF generator, which wa ...

PDF 1 MB
All Matrix Solution System for NexION ICP-MS Platforms

PerkinElmer’s All Matrix Solution (AMS) system provides a number of benefits to simplify analysis of high-matrix samples with the NexION family of ICP-MS instruments. It allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to s ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...

PDF 1 MB

Video

Syngistix for ICP-MS Software for the NexION Series Instruments

Syngistix™ for ICP-MS software for the NexION® ICP-MS series instruments is designed with your workflow in mind to make it easy for you to set up and report your analyses, upleveling your experience.

Video
All Matrix Solution Feature on NexION ICP-MS Series Instruments

PerkinElmer’s All Matrix Solution, available on all NexION® ICP-MS instruments, allows online gas dilution of your samples, both improving efficiency and preventing contamination.

Video

Webinars

A Seamless Trace Elemental Analysis Prescription to Quality Pharmaceuticals

Quality assurance and quality control are key components of every pharmaceutical manufacturing. To meet the standards set by U.S. Pharmacopeia (USP) <232> and the International Council for Harmonization (ICH) Q3D, QA/QC labs performing routine trace-elem

Webinars