PerkinElmer

Columns

OF

Ensure the best results from your chromatography analysis with our high-performance columns. Choose from our wide selection of HPLC and LC columns as well as GC columns for both your PerkinElmer and non-PerkinElmer chromatography instrumentation.

Products & Services (915)
Filters:

Filters :

Product Type
  • Accessories (6)
  • Consumables (909)
Product Brand Name
  • Aquapore (16)
  • Brownlee SPP (7)
  • Elite (21)
  • Elite-1 (84)
  • Elite-1301 (17)
  • Elite-17 (31)
  • Elite-1701 (30)
  • Elite-17ht (High Temperature) (5)
  • Elite-17ms (9)
  • Elite-17ms+ (9)
  • Elite-1ht (3)
  • Elite-200 (34)
  • Elite-225 (13)
  • Elite-23 (2)
  • Elite-35 (10)
  • Elite-35ms (9)
  • Elite-5 (41)
  • Elite-5 Amine (1)
  • Elite-5 Anime (10)
  • Elite-502.2 (4)
  • Elite-5ht (High Temperature) (3)
  • Elite-5ms (22)
  • Elite-5MS (21)
  • Elite-608 (9)
  • Elite-624 (10)
  • Elite-Alumina (3)
  • Elite-BAC (6)
  • Elite-BAC Advantage (1)
  • Elite-Betacyclodextrin (1)
  • Elite-CL Pesticides (11)
  • Elite-Cyclosil (1)
  • Elite-FFAP (8)
  • Elite-Molesieve PLOT Phase (1)
  • Elite-MTBE (2)
  • Elite-PONA (1)
  • Elite-Q PLOT (2)
  • Elite-RX (5)
  • Elite-Siltek (2)
  • Elite-SimDist (2)
  • Elite-TPH (2)
  • Elite-VMS (10)
  • Elite-Volatiles (6)
  • Elite-WAX (29)
  • Elite-WAX ETR (24)
  • Elite-XLB (15)
  • Pecosphere (8)
  • Polypore (2)
  • Quasar (86)
  • Spheri-10 (5)
  • Spheri-5 (16)
  • Validated (1)
  • Velocity-1 (6)
  • Velocity-5 (3)
  • Velocity-Wax (3)
Film Thickness
  • 0.02 µm (1)
  • 0.05 µm (3)
  • 0.1 µm (36)
  • 0.15 µm (29)
  • 0.18 µm (11)
  • 0.2 µm (7)
  • 0.25 µm (115)
  • 0.3 µm (3)
  • 0.33 µm (17)
  • 0.34 µm (1)
  • 0.4 µm (11)
  • 0.42 µm (13)
  • 0.5 µm (65)
  • 0.52 µm (2)
  • 0.6 µm (1)
  • 0.7 µm (2)
  • 0.83 µm (2)
  • 0.85 µm (18)
  • 1.0 µm (92)
  • 1.12 µm (1)
  • 1.27 µm (6)
  • 1.4 µm (8)
  • 1.5 µm (20)
  • 1.7 µm (3)
  • 1.8 µm (9)
  • 10.0 µm (4)
  • 2.0 µm (5)
  • 2.55 µm (13)
  • 20.0 µm (1)
  • 3.0 µm (21)
  • 4.0 µm (1)
  • 4.25 µm (4)
  • 5.0 µm (8)
  • 50.0 µm (1)
Inner Diameter
  • 0.0 mm (1)
  • 0.0 mm (2)
  • 0.1 mm (10)
  • 0.15 mm (2)
  • 0.18 mm (8)
  • 0.2 mm (79)
  • 0.25 mm (127)
  • 0.3 mm (96)
  • 0.32 mm (66)
  • 0.4 mm (43)
  • 0.45 mm (15)
  • 0.5 mm (51)
  • 0.53 mm (44)
  • 1 mm (1)
  • 2.0 mm (14)
  • 2.1 mm (41)
  • 3 mm (44)
  • 3.2 mm (7)
  • 3.9 mm (1)
  • 4.0 mm (7)
  • 4.6 mm (92)
Length
  • 0-10 (68)
  • 11-20 (188)
  • 21-30 (252)
  • 31-40 (8)
  • 41-50 (78)
  • 51-100 (182)
  • 101-200 (60)
  • 201-300 (33)
Particle Size
  • 1.7 µm (15)
  • 2.6 µm (23)
  • 2.7 µm (14)
  • 3.0 µm (31)
  • 5.0 µm (51)
  • 7.0 µm (14)
  • 10.0 µm (8)
  • 20.0 µm (2)
Phase
  • (6%-cyanopropylphenyl)-methylpolysiloxane (17)
  • (low bleed) (1)
  • 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane (22)
  • 100% dimethyl polysiloxane (22)
  • 100% Dimethyl Polysiloxane (59)
  • 35% Diphenyl / 65% Dimetyl Polysiloxane (1)
  • 5% diphenyl / 95% dimethyl polysiloxane (34)
  • 5% diphenyl / 95% dimethyl polysiloxane (3)
  • 5% Diphenyl and 95% Dimethyl Polysiloxane (3)
  • 5% Diphenyl/95% Dimethyl Polysiloxane (10)
  • 5% Phenyl/ 95% Dimethyl Polysiloxane (1)
  • 6% cyanopropylphenyl / 94% dimethylpolysiloxane (2)
  • Alumina (3)
  • Amino (3)
  • Anion exchange (3)
  • Betadextrin (1)
  • C18 (19)
  • C4 (2)
  • C8 (14)
  • Cyano (3)
  • Cyanoprpylphenyl dimethyl polysiloxane (31)
  • Cycanopropylmethyl-phenylmethylpolysiloxane (13)
  • Cyclosil (1)
  • Dimethyl Polysiloxane (15)
  • Dimethyl Polysiloxane (1)
  • Diphenyl Dimethyl Polysiloxane (62)
  • HILIC (2)
  • IBD (1)
  • No Phase Coating (2)
  • Peptide ES-C18 (2)
  • PFP (2)
  • Phenyl (2)
  • phenyl group in the polymer backbone (2)
  • Phenyl Hexyl (2)
  • Phenyl Methyl Polysiloxane (46)
  • Polyethylene Glycol (55)
  • Polymer (2)
  • RP-Amide (2)
  • Silica (3)
  • Trifluoropropylmethyl polysiloxane (34)
Product Group
  • Cartridge Columns (28)
  • Cartridges (7)
  • Conventional Columns (20)
  • GC (29)
  • Guard Columns (7)
Technology
  • Anion Exchange (1)
  • Capillary (187)
  • Capillary - General Purpose (144)
  • Capillary - Specialty Application (42)
  • Cartridge (89)
  • Cartridge Column (33)
  • Conventional (59)
  • Conventional Column (6)
  • Conventional-Guard (2)
  • Custom Packed Columns (24)
  • Guard column (7)
  • Reverse Phase (3)
Technology Type
  • Liquid Chromatography (LC) (62)

1-25 of 915 Products & Services

Sort by

  • PerkinElmer

    Elite-SimDist capillary column 10m x 0.53mm, 3.00µm

    The Elite-SimDist columns are specifically for the simulated distillation application. The phase is specifically processed for dimethylpolysiloxane.
    List Price : 341.00 USD
  • Replacement column set for the Model 4019

    Compatible with the NGA Model 4019 for Light and combustion gas.

    List Price : 9000.00 USD
  • PerkinElmer

    Elite-17ht capillary column 15m x 0.32mm, 0.15µm

    Elite-17ht Columns are extremely versatile, permitting the analysis pesticides, herbicides, rosin acids, phthalate esters, triglycerides, and sterols.
    List Price : 439.00 USD
  • PerkinElmer

    Elite-17ht capillary column 60m x 0.32mm, 0.15µm

    Elite-17ht Columns are extremely versatile, permitting the analysis pesticides, herbicides, rosin acids, phthalate esters, triglycerides, and sterols.
    List Price : 2332.00 USD
  • Elite-200 capillary column 30m x 0.53mm, 1.50µm

    The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
    List Price : 800.00 USD
  • PerkinElmer

    Elite PONA capillary column, 50m x 0.20mm, 0.50µm

    The Elite PONA columns have a specially processed dimethyl polysiloxane phase for the detailed analysis of petroleum naphtha
    List Price : 1208.00 USD
  • CartC220

    Brownlee Spheri-5 ODS Cartridge Column

    Polyfunctional ODS phase to provide slight differences in selectivity.

    Price Range : 265.00 USD - 585.00 USD
  • Replacement column set for the Model 4024

    Compatible with the NGA Model 4024 for UOP 603.

    List Price : 1864.00 USD
  • PerkinElmer

    Elite-5MS capillary column 15m x 0.32mm, 0.25µm

    Elite-5ms Columns are fused silica columns coated for EPA Wastewater Methods for Organic Chemical Analysis Method 611.
    List Price : 489.00 USD
  • Elite-5 Amine capillary column 15m x 0.32mm, 1.00µm

    Elite-5 Amine Capillary Columns are an amine version of the standard Elite-5 column, engineered for the analysis of amines and other basic compounds.
    List Price : 508.00 USD
  • Elite-200 capillary column 15m x 0.53mm, 3.00µm

    The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
    List Price : 528.00 USD
  • 3um_cart_angle_700x700

    Quasar™ C18 Guard Cartridge

    Quasar C18 LC columns, based on ultra high purity silica and manufactured to tight specification, provides high efficiency separations and excellent peak shape for a wide range of compounds. Our methodology to yield high surface coverage enhances the pH stability and extends the working range. If data integrity and high producitvity are top priorities for your lab, then this column can support your needs for any application.
    List Price : 174.00 USD
  • PerkinElmer

    Elite-35ms capillary column 15m x 0.32mm, 0.25µm

    Elite-35ms columns are general purpose, mid polarity phases coated with a unique blend of linked dimethyl polysiloxanes and diphenyl polysiloxanes. The resulting inert phase is selective to polar compounds such as drugs, pesticides, herbicides and PCB's whilst maintaining a similar selectivity as traditional Elite 35 phaes.
    List Price : 540.00 USD
  • PerkinElmer

    Elite-5 capillary column, 10m x 0.18mm, 0.40µm

    Elite-5, 5% phenyl/95% dimethyl polysiloxane, is a general purpose, low polarity phase used in a wide variety of applications. Amongst others, they are commonly used for analysis of drugs, pesticides, hydrocarbons, PCB's, essential oils, semivolatiles and solvent impurities.
    List Price : 372.00 USD
  • PerkinElmer

    Elite-5MS II Capillary Column, 30 m x 0.25 mm, 0.25 µm

    The Elite-5MS II columns incorporate the same phase as the Elite-5 coumns but are specifically tested for low bleed performance. This configuration combines both the anlaytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
    List Price : 638.00 USD
  • CartC220

    Brownlee Spheri-5 Phenyl cartridge column, 220 x 4.6mm, 5µm

    Especially suited for hydrophobic interaction separation of biomolecules, where the activity of the compound must be preserved.

    List Price : 545.00 USD
  • 150x4_6mm_angle_700x700

    Quasar™ C18 LC Column

    Quasar C18 LC columns, based on ultra high purity silica and manufactured to tight specification, provides high efficiency separations and excellent peak shape for a wide range of compounds. Our methodology to yield high surface coverage enhances the pH stability and extends the working range. If data integrity and high productivity are top priorities for your lab, then this column can support your needs for any application.
    Price Range : 577.00 USD - 605.00 USD
  • PerkinElmer

    Elite-5MS capillary column 15m x 0.32mm, 1.00µm

    Elite-5ms Columns are fused silica columns coated for EPA Wastewater Methods for Organic Chemical Analysis Method 611.
    List Price : 453.00 USD
  • PerkinElmer

    Elite-17ht capillary column 30m x 0.32mm, 0.15µm

    Elite-17 Columns are for confirmation analysis and are inert for active compounds.
    List Price : 644.00 USD
  • PerkinElmer

    Maintenance Kit, GC Capillary Column Cutter (1/pack)

    Use our capillary column cutting tool to ensure a perfect cut of your GC column, first time, every time. The rotating diamond blade with a built in magnifier to verify a square cut, affords a precise clean cut of fused silica columns. Suitable for use with 0.25 mm ID to 0.53 mm ID tubing, (0.78 mm OD maximum). Contains replacement cutting wheel, O-Rings, and tool to open the cutter.
    List Price : 174.00 USD
  • PerkinElmer

    Elite-1 capillary column, 15m x 0.32mm, 0.10µm

    Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
    List Price : 427.00 USD
  • Elite-200 capillary column 60m x 0.53mm, 0.50µm

    The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
    List Price : 1247.00 USD
  • 150x4_6mm_angle_700x700
    Price Range : 605.00 USD - 762.00 USD
  • PerkinElmer

    Quasar™ SPP PFP LC Column

    Quasar SPP PFP LC columns consists of a pentafluorophenyl (PFP), bonded phase which provides π-π interactions to facilitate alternative selectivity.
    Price Range : 571.00 USD - 706.00 USD
  • PerkinElmer

    Elite-WAX ETR capillary column 5m x 0.53mm, 2.00µm

    Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax® to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAME's, flavor compounds, solvents, aromatocis, impurities in water and alcoholic beverages.
    List Price : 583.00 USD
  • Jump to:
Business Insights (4)
Filters:

1-4 of 4 Business Insights

Sort by