NexION 2000S ICP Mass Spectrometer | PerkinElmer
PerkinElmer
check quantity

NexION 2000S ICP Mass Spectrometer

PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

PerkinElmer received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for laboratories testing semiconductors and fine chemicals, the NexION 2000S ICP-MS features:

  • A dedicated SMARTintro High Purity sample-introduction module minimizes contamination and delivers low background equivalent concentrations (BECs))
  • Built-in cold plasma capabilities which, combined with Reaction mode, deliver PPQ detection limits
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Small footprint to minimize bench space
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000S
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Determination of Organotin in Tap Water by HPLC-ICP-MS in Accordance with Chinese Method HJ 1074-2019

Organotin compounds are widely used across industry and agriculture, resulting in widespread pollution of various environmental media, including potable water. Among these compounds are tributyltin (TBT), triphenyltin (TPT), dibutyltin (DBT), and diphenyltin (DPT), in the following order of persiste ...

PDF 506 KB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep into ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperature, ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that PerkinElmer's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and ...

PDF 1 MB
Analysis of Drinking and Natural Waters with the NexION 2000 ICP-MS

This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...

PDF 1 MB
Analysis of Iron Nanoparticles in Semiconductor Organic Solvents Using Single Particle ICP-MS in Reaction Mode

Metallic contamination in semiconductor products adversely affects device performance. Transition metals are among the most commonly occurring forms of metal contamination – they tend to diffuse through the semiconductor material and aggregate on the surface in various oxide forms, and iron (Fe) is, ...

PDF 1 MB
Analysis of Rare Earth Elements by Laser Ablation-ICP-MS with the NexION 2000 ICP-MS

With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to me ...

PDF 1 MB
Analysis of SiO2 Nanoparticles in Reaction Mode with Single Particle ICP-MS

With the increased use of nanoparticles (NPs) in various products and processes, the need to characterize them has also increased. Single Particle ICP-MS (SP-ICP-MS) was developed for rapid analysis of nanoparticles, measuring thousands of particles in less than a minute, while providing individual ...

PDF 606 KB
Analysis of SiO2 Nanoparticles in Standard Mode with Single Particle ICP-MS

With the development of nanotechnology and the increased use of nanoparticles (NPs) in numerous products and processes, the need to characterize them has also grown. Nanoparticles come in a wide variety of compositions, with silica dioxide (SiO2) nanoparticles being used in many areas. For successfu ...

PDF 1 MB
Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

PDF 555 KB
Boron Isotope Ratio Analysis Using the NexION ICP-MS

Boron (B) is studied for its isotope ratio composition in a range of paleoproxy, geochemical, nuclear, medical, and archeological applications. ICP-MS is recognized as a powerful technique for boron isotope analysis. Quadrupole ICP-MS is versatile and not exclusively dedicated to isotope ratio measu ...

PDF 3 MB
Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

In semiconductor device fabrication, in an effort to reduce the size of electronic devices and improve the yield of the manufacturing process, chemical-mechanical planarization (CMP) slurries consisting of nanoparticles are now in use. CMP is a process of smoothing surfaces with the combination of c ...

PDF 1 MB
Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of PerkinElmer's NexION ...

PDF 516 KB
Compendium - Reliable Methods for Nutritional & Toxic Analysis of Breakfast Foods

Breakfast is an important meal in providing essential nutrients to keep your energy levels up throughout the day. How do we ensure the food and beverages we consume are healthy, nutritious and safe? Following is a collection of application notes highlighting solutions that will help you identify mic ...

PDF 15 MB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical and ...

PDF 1 MB
Determination of Trace Elements in Eye Drops with the NexION ICP-MS

Eye drops are commonly used medications which are available both over-the-counter and as prescriptions in various forms. Because eye drops are classified as a parenteral medication and have relatively large daily doses, the inorganic components in eye drops must be present at low concentrations. As ...

PDF 475 KB
Digestion, Testing, and Validation of Heavy Metals in Cannabis

Owing to the toxicity of heavy metals, it is increasingly important to test cannabis flowers and other cannabis derivatives so that patient and consumer safety is maintained as the use of cannabis becomes more common. This need has translated into an increasing demand for testing cannabis flowers an ...

PDF 1 MB
Direct Determination of Trace Elements in Nickel-Based Superalloys with the NexION 2000 ICP-MS

Nickel-based superalloys benefit from high heat resistance, high melting points, retention of mechanical and chemical properties at high temperatures, and high corrosion resistance, among others, and are therefore widely used in challenging environments, such as aircraft and power generation turbine ...

PDF 916 KB
Extraction of Gold Nanoparticles from Fish Larvae and Soils

Gold nanoparticles (AuNPs) are widely used in industrial and medical applications. They are known to form naturally during the weathering of Au-bearing mineral deposits, as well as the transformation of gold nuggets and particles. In freshwater systems, they bioaccumulate in aquatic organisms, as sh ...

PDF 1 MB
Iron Nanoparticles by SP-ICP-MS: Overcoming Spectral Interferences Using Universal Cell Technology

With the increasing interest in nanoparticles (NPs), various ways of detecting and measuring them are being used. One of the most promising techniques for analyzing metallic NPs is single particle ICP-MS (SP-ICP-MS). This work demonstrates the ability of the NexION® SP-ICP-MS with Universal Cell Tec ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its hig ...

PDF 1 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of PerkinElmer's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Quantification of Nanoparticle Uptake into Cancer Cells using Single Cell ICP-MS

Nanoparticles (NPs) have been of significant interest over the last two decades as they offer attractive benefits for drug delivery to overcome limitations in conventional chemotherapy. Nanoparticles can be engineered to carry both drugs and imaging probes to simultaneously detect and treat cancer. ...

PDF 906 KB
SP-ICP-MS Analysis of Size and Number Concentration in Mixtures of Monometallic and Bimetallic (Core-shell) Nanoparticles

Separating and measuring the physical and chemical properties of monometallic and bimetallic engineered nanoparticles (NPs) is challenging, especially when mixtures of NPs consist of particles of similar size, composition, and especially when present at low concentrations. Fully characterizing suspe ...

PDF 1 MB
Speciation of Hexavalent Chromium in Children's Toys According to EN 71-3 Category II with the NexSAR HPLC-ICP-MS

Testing for harmful metal(loid)s that may be included in raw materials, processes, paints and additives used in the manufacturing processes of children's toys has been mandated by the regulation EN 71-3. This regulation recommends specific testing methods and maximum allowable concentrations of leac ...

PDF 918 KB
Testing and Validation of Various Antacids for Elemental Impurities using the NexION 2000 ICP-MS

The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...

PDF 576 KB

Brochure

Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading met ...

PDF 9 MB
Comprehensive and Compliant Solutions for Glass Analysis

It’s clear, glass has a variety of uses, from practical to technological to decorative. In particular, float glass is widely used in architecture, automotive, transportation, photovoltaic, and solar industries. For glass testing labs around the world, we offer highly accurate and tailored solutions ...

PDF 2 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics. PerkinElmer is equipped to help the grain indus ...

PDF 6 MB
Meat and Seafood Testing Solutions

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle. Our commitment ...

PDF 6 MB
Refinery and Natural Gas Analysis Brochure

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is cri ...

PDF 5 MB
USP <232>/<233> & ICH Q3D Capabilities Brochure

The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. Pharmacopeia’s (USP) Chapters <232> and <233> on elemental impuriti ...

PDF 3 MB

Catalog

Atomic Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 8 MB

Flyer

Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve their ...

PDF 587 KB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available: Atomic absorption (AA): flame and graphite furnace Inductively coupled plasma optical emission spectroscopy (ICP ...

PDF 1 MB
NexION 1000/2000 ICP-MS Preparing Your Laboratory

PerkinElmer ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION ICP-MS Series Consumables & Supplies Guide

Whether looking for sample introduction components or standards, we have the consumables you need to keep your NexION up and running smoothly and efficiently.

PDF 2 MB

Regulatory Compliance Certification

Product Certificate - NexION 1000/2000

Product Certificate for the NexION 1000/2000

PDF 98 KB

Technical Note

All Matrix Solution System for NexION ICP-MS Platforms

PerkinElmer’s All Matrix Solution (AMS) system provides a number of benefits to simplify analysis of high-matrix samples with the NexION family of ICP-MS instruments. It allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to s ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...

PDF 1 MB

Training

Webinars

White Paper

The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hygie ...

PDF 683 KB