Sort by
1-25 of 172 Products & Services
Its unique three-quad design, combined with novel and proven technologies, including the second-generation Triple Cone Interface with OmniRing™, come together to offer outstanding sensitivity, superior interference removal, excellent stability, unmatched matrix tolerance, high throughput/greater uptime, as well as sustainability and low cost of operation.
This 0.5 mm Internal Standard Addition Tee is for use with PFA-ST Nebulizers in NexION 1000/2000 ICP-MS series instruments. This mixing tee is perfect for online addition of internal standard or online dilution and achieves excellent mixing with minimal dead volume.
This Laser Connector and Tubing is for use with injectors in NexION® 1000/2000 ICP-MS series instruments.
This Sample Introduction Line, with 0.5 mm I.D. and orange marker, is for use with NexION® 1000/2000 ICP-MS series instruments. It is designed for use with MicroFlow PFA-ST nebulizers and includes the fluoropolymer micro pump tubing fitting.
This Peripump Union, with 10-32 female threads and dual flaring, is for use with NexION® 1000/2000 ICP-MS series instruments. It adapts 10/32 to pump tubing.
This Baffled Quartz Cyclonic C3 High Sensitivity Spray Chamber is used with NexION® 1000 and 2000 ICP-MS series instruments. It is an ideal all-purpose spray chamber for non-HF samples and provides excellent sensitivity, stability, and reduced boron blank. This spray chamber is designed for applications requiring low levels of boron and silicon detection and includes a Matrix Gas Port.
This threaded spray chamber drain line, with Santoprene™ tubing attachment, is used with NexION® 2000 ICP-MS series instruments.
This SilQ Baffled Cyclonic C3 High Sensitivity Spray Chamber is used with NexION® 1000 and 2000 ICP-MS series instruments. It is recommended for use in the NexION® 2000 Semiconductor Configuration and is an ideal all-purpose spray chamber for non-HF samples.
This Baffled Cyclonic C3 High Sensitivity Spray Chamber is used with NexION® 1000 and 2000 ICP-MS series instruments. It is recommended for use in the NexION® 2000 Base Configuration and is an ideal all-purpose spray chamber for non-HF samples.
Sort by
1-20 of 20 Resource Library
With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical and ...
Through the years, both industry and analytical instrumentation have advanced. With the development of new chemicals and processes, new pollutants may enter the environment. However, the capabilities of analytical instruments have also increased, allowing the measurement of ever lower levels of envi ...
Plant-based foods using ingredients derived from fruits, nuts, vegetables, grains, and legumes, have gained increased attention for a variety of reasons, including but not limited to nutritional, environmental, sustainability, and ethical issues. While they have many benefits, they also present chal ...
While plant-based foods offer many benefits, they carry some challenges associated with their formulation, nutritional content, and safety. Nutritional and toxic elements need to be routinely monitored in incoming raw materials and finished product, ensuring accurate label claims and compliance with ...
The late 20th century to early 21st century has been described as the Silicon Age, because of the large impact that elemental silicon (Si) has had on the world economy. Highly purified Si used in semiconductor electronics is essential in the production of transistors and integrated circuit chips use ...
Concentrations of toxic elements in foods are present at trace to ultra-trace levels, requiring sensitive and reliable analytical techniques for accurate measurement. ICP-MS is a powerful technique with multi-element detection capabilities, low detection limits, high speed of analysis, and wide line ...
The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...
Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.
Analytical testing labs like yours performing trace-elemental analysis with varied sample types and matrices need to deliver accurate, repeatable results, day in and day out. And that means an ICP-MS you can count on – one that’s easy to use and simple to maintain, for maximum uptime; that helps kee ...
TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...
Food alteration has been increasing substantially in recent years, leading to substandard products. Therefore, to ensure the health and safety of the consumer, it is essential to characterize foods for toxic and nutritional elements accurately and rapidly, and ICP-MS is the ideal technique for these ...
Milk and milk powder are used widely in the food industry for the production of other foods. Because of its nutritional importance and widespread consumption, regulations in many countries necessitate that the quality of the milk is routinely monitored.
For many children around the globe, commercial baby foods are the main source of nutrients and energy, and therefore their quality and safety are critical and must be monitored. In March 2021, the U.S. House of Representatives introduced the “Baby Food Safety Act of 2021” to regulate the presence of ...
This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...
In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of PerkinElmer's NexION ...
In this work, we demonstrate that PerkinElmer's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...
Nickel-based superalloys benefit from high heat resistance, high melting points, retention of mechanical and chemical properties at high temperatures, and high corrosion resistance, among others, and are therefore widely used in challenging environments, such as aircraft and power generation turbine ...
With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to me ...
Due to high total dissolved solids (TDS), seawater is considered one of the most difficult matrices to analyze for the presence of heavy metals and other trace elements. Plus, trace elements in open-ocean seawater are even lower than in coastal areas, thus are more challenging to accurately measure ...
Laser ablation-ICP-MS (LA-ICP-MS) has become an increasingly popular tool for imaging due to its ability to provide spatially resolved elemental information at low concentrations. Many aspects need to be considered when setting up an LA-ICP-MS system for imaging. Laser scanning speed, stage accuracy ...