Blue Injection Port Septa, Pkg. 50

Septa rated to 275 °C. The blue septa are designed for routine applications. Employing a soft silicone rubber material and stay clean surface, they are easy to penetrate without a recess.

Part Number
Quantity in a Package Amount
List Price
Your Price
Quantity
N9306874
50.0
73.00 USD
 
more
N9306873
10.0
17.00 USD
 
more
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

As the blue septa used at lower operating temperatures the non-stick coating is not required to prevent inlet adhesion. They offer a low level of inertness and for routine GC applications providing optimum performance at lower operating temperatures.

Specifications

Color Blue
Model Compatible With Clarus 680, Clarus 480, Clarus 590, Clarus 580, Clarus 690
Outer Diameter 11 mm
Product Brand Name Blue Injection Port Septa
Product Group Injection Port Septa
Quantity in a Package Amount 50.0
Resources, Events & More
  • All

Catalog

Product Note

Technical Note

Inlet Septum Maintenance for the Clarus 580-680 Capillary Split-Splitless Injector

This technical note outlines the inlet septum replacement procedure for the CAP injector assembly (Item #: N6100007, 120V; N6100137, 230V) for the Clarus® 500/580, & 600/680 GC platforms. The injector assembly is designed for quick access to the inlet septum for routine maintenance and easy integration into daily workflows. Figure 1 provides a diagram of the injector assembly as viewed from the top of the instrument chassis, highlighting placement of the septum cap (Item #: N6100153) containing the septum within.

PDF 666 KB
Inlet Septum Maintenance for the Clarus 590-690 Capillary Split-Splitless Injector

When compared to the exacting attention that gas chromatographers pay the analytical column, it often seems that the inlet septum receives relatively little consideration. In fact, many chromatographers are surprised to discover that GC instrument manufacturers recommend daily inspection and/or replacement of the inlet septum to maximize instrument performance. Although inexpensive compared to other chromatography consumables, a freshly replaced septum is essential for maintaining system isolation from the outside environment.

A poorly maintained inlet will cause the instrument to suffer from diminished sensitivity, shifting response factors, asymmetrical peak shapes, and an overall poorer precision and accuracy compared to a well-maintained one. When older, damaged septa are cored by the syringe needle these cores of septa can drop into the inlet liner, blocking the flow of gas and releasing bleed volatiles onto the column. Such detriments impact system sensitivity and inevitably result in unscheduled maintenance and more frequent calibrations.

This technical note outlines the inlet septum replacement procedure for the capillary split/splitless (CAP) injector (Item #: N6120146) for the Clarus® 590/690 GC platform.

PDF 566 KB