Natural Gas Analyzers - Model 2106 | PerkinElmer
PerkinElmer
check quantity

Natural Gas Analyzers - Model 2106

The efficient and accurate analysis of natural gas, liquids and pressurized liquids, and the calculation of its physical properties are of critical importance to ensuring safety and quality during the production and transport of natural gasses. Owing to the varied and substantial nature of both organic and inorganic constituents in natural gas samples, it is imperative that operators utilize an analyzer created specifically for natural gas analysis. PerkinElmer offers a wide selection of pre-configured, easy to operate natural gas analyzers that provide the flexibility to consider all types of samples, analyzing components of interest in gas, liquid and pressurized liquid samples using TCD and FID detection.

Part Number
Type
Sample Type
Detector Type
NARL8205
Model 2001
Gas
TCD
more
NARL8206
Model 2101
Gas
TCD/TCD
more
NARL8207
Model 2201
Gas, Pressurized Liquid
TCD
more
NARL8208
Model 2301
Gas, Pressurized Liquid
TCD/TCD
more
NARL8210
Model 2002
Gas
TCD
more
NARL8215
Model 2003
Gas
TCD
more
NARL8216
Model 2103
Gas
TCD/TCD
more
NARL8241
Model 2103H2
Gas
TCD/TCD
more
NARL8217
Model 2203
Gas, Pressurized Liquid
TCD
more
NARL8218
Model 2303
Gas, Pressurized Liquid
TCD/TCD
more
NARL8220
Model 2006
Gas, Liquid
FID, TCD
more
NARL8221
Model 2106
Gas, Liquid
TCD/TCD/FID
more
NARL8222
Model 2206
Gas, Liquid, Pressurized Liquid
TCD/FID
more
NARL8223
Model 2306
Gas, Liquid, Pressurized Liquid
TCD/TCD/FID
more
NARL8224
Model 2406
Gas, Liquid, Pressurized Liquid
TCD/TCD/FID
more
NARL8225
Model 2008
Gas, Liquid
TCD/TCD/FID
more
NARL8226
Model 2108
Gas, Liquid
TCD/TCD/FID
more
NARL8240
Model 2108H2
Gas, Liquid
TCD/TCD/FID
more
NARL8227
Model 2208
Gas, Liquid, Pressurized Liquid
TCD/FID
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

NGA Model 2106 features three channels – dual thermal conductivity and single flame ionization detector (TCD/TCD/FID) - to achieve full range helium and hydrogen detection in gas samples. Designed to ensure that the lowest boiling C6 compound (2,2-dimethylbutane) is included in the backflush on the TCD channel, Model 2106 reduces interference potential while also preventing degradation from common contaminants with rugged packed columns. Compliant with the requirements set forth in ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5 and DIN 51872-5, Model 2106 provides detection levels of 0.01% for helium and hydrogen, 0.01% for O2/N2 composite, CO2, C1 through C5 and a C6+ composite peak, and 0.1% for H2S on the TCD channels, and 0.001% for all components on the FID channel.

Specifications

Detector Type TCD/TCD/FID
Sample Type Gas, Liquid
Type Model 2106