Liners

OF

Secure your GC columns against column contamination. Our glass split and splitless inlet liners promote full vaporization of samples, minimize mass discrimination, and help you achieve accurate and reproducible results every time. Some liners are even packed with wool, helping to trap non-volatile material.

From capillary and programmed temperature liners to packed liners available in both clear and color coded, we have what you need for all of your gas chromatography needs.

  • Products and Services

  • Resources, Events & More

Narrow your results
Product Type
  • Accessories (1)
  • Consumables (46)
  • Reagents (3)
Format
  • Microplates (3)
Inner Diameter
  • 0.18 mm (1)
  • 0.53 mm (1)
  • 1 mm (3)
  • 1.25 mm (1)
  • 2 mm (13)
  • 2.4 mm (1)
  • 3 mm (1)
  • 4 mm (19)
  • 6 mm (2)
Length
  • 51-100 (39)
  • 101-200 (1)
  • 301-400 (1)
Outer Diameter
  • 0.5 mm (1)
  • 0.8 mm (1)
  • 2 mm (1)
  • 4 mm (13)
  • 5 mm (1)
  • 6 mm (1)
  • 6.2 mm (23)
  • 6.3 mm (1)
  • 8 mm (1)
Technology Type
  • Capillary Split/Splitless (18)
  • O-ring (1)
  • Packed Clear (10)
  • Packed Colored (6)
  • Packing material (1)
  • Programmed Temperature Split/Splitless (PSS) (9)

"Liners" 1-50 of 50 Products and Services

Sort

Waste Bag, 100/PK

For safe disposal of used samples, we supply plate-sized sample bags.
List Price : 138.00 USD

Sample Bag, for MicroBeta Trilux, 100/PK

These are plastic bags used for direct counting of filters in MicroBeta TriLux. The samples are enclosed in the bags allowing convenient and economical use of scintillant and minimizing disposal volumes. The bags provide additional safety when handling biohazardous materials.
List Price : 108.00 USD

MultiScreen Liner, Liner To Fit Millipore MultiScreen Filter into the MicroBeta 1450-106 Cassette

This liner is for use with the Millipore Multiscreen Cassette, which holds the Millipore Multiscreen filter plates in MicroBeta.
List Price : 42.00 USD
List Price : 316.00 USD
List Price : 156.00 USD

Splitless Liner 1mm Package of 5

Splitless Liner 1mm; 1mm I.D x 6.2mm O.D x 92.1mm length
List Price : 196.00 USD

Cyclo Splitter Split Liner 4mm Package of 5

This patented design incorporates a cylindrical glass spiral in the sample pathway, providing a large area for sample vaporization.
List Price : 306.00 USD

Splitter Split Liner with Wool 4mm Package of 5

Splitter Split Liner with Wool 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 172.00 USD

Cyclo Double Gooseneck Splitless Liner 4mm Package of 5

Cyclo Double Gooseneck Splitless Liner 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 302.00 USD

PSS Siltek Deactivated Split/Splitless Liner 2mm Package of 5

PSS Siltek Deactivated Split/Splitless Liner 2mm; 2mm I.D x 4.0mm O.D x 86.2mm length
List Price : 328.00 USD

Cup Splitter Split Liner 4mm Package of 5

Cup Splitter Split Liner 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 308.00 USD

Deactivated Liner (4 mm, packed with wool) for Split Operation

Universal liner for general 4 6.2 92.1 5 N6121020 236 purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken
List Price : 327.00 USD

SPLITLESS GLASS LINERS Deact., w/Deact. Wool, 5/pack

Capillary splitless deactivated glass liners 4mm I.D. x 6.2mm O.D. x 92.1mm, with deactivated wool 5/pack.
List Price : 168.00 USD

PSS Siltek Deactivated Split/Splitless Liner with Wool 2mm Package of 5

PSS Siltek Deactivated Split/Splitless Liner with Wool 2mm; 2mm I.D x 4.0mm O.D x 86.2mm length. Wool provides a large surface area to allow rapid vaporization of the sample and deliver a uniform vaporn cloud to the split point. The low mass of wool fiber promotes complete vaporization.
List Price : 398.00 USD

Splitless Liner 2mm, Package of 5

Splitless Liner 2mm; 2mm I.D x 5.0mm O.D x 100mm length
List Price : 199.00 USD
List Price : 144.00 USD

PSS Siltek Deactivated Split/Splitless Liner with Wool 1mm Package of 5

PSS Siltek Deactivated Split/Splitless Liner with Wool 1mm; 1mm I.Dx 4.0mm O.D x 86.2mm length. Wool provides a large surface area to allow rapid vaporization of the sample and deliver a uniform vapor cloud to the split point. The low mass of wool fiber promotes complete vaporization.
List Price : 471.00 USD
List Price : 168.00 USD
List Price : 27.00 USD

Open-top Uniliner with Wool 4mm Package of 5

Open-top Uniliner with Wool 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 282.00 USD

Blue GC Inlet Liners Package of 5

Application - For low volume sample analysis; great for fast GC, gaseous samples (purge and trap)Small injections (0.5uL or less), not suitable for>1uL injections. Capable of giving low and high boiling point discriminations. Color coded BLUE on the liner with PKI name
List Price : 163.00 USD

Glass Injector Liner 2 mm i.d x 4 mm o.d. x 86.2 mm length Package of 5

This glass liner is specifically designed to be used for Fuel in Oil analysis.
List Price : 345.00 USD

LINER-CAP AS SPLTLS WOOL 4MM UNIV Package of 5

Capillary splitless deactivated glass liners 4mm I.D. x 6.2mm O.D. x 92.1mm with deactivated wool 5/pk
List Price : 157.00 USD

Siltek Splitter Split Liner with Wool 4mm Package of 5

Siltek Splitter Split Liner with Wool 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 260.00 USD
List Price : 26.00 USD
List Price : 30.00 USD
List Price : 32.00 USD
List Price : 33.00 USD

2-mm Split Mode Quartz Liner for Programmable Split/Splitless Injector

2mm Split Mode Quartz Liner for Programmed-Temperature Split/Splitless Inlet System
List Price : 22.00 USD
List Price : 33.00 USD

Double Gooseneck Splitless Liner 4mm Package of 5

Double Gooseneck Splitless Liner 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
List Price : 158.00 USD

LINER CAP AS SPLTLS WOOL 4MM UNIV

Capillary splitless deactivated glass liners 4mm I.D. x 6.2mm O.D. x 92.1mm, with deactivated wool 1/pack
List Price : 33.00 USD

Gooseneck Drilled Uniliner (hole on top) 4mm Package of 5

The Drilled Uniliner® with the hole near the bottom is recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. The Drilled Uniliner® with the hole near the top is recommended for aqueous injections. A hole drilled into this liner allows direct injection in EPC systems and reduces sample discrimination.
List Price : 388.00 USD

Red Capillary splitless glass injector liner packed loosely with wool

Capillary splitless deactivated glass liners 4mm I.D. x 6.2mm O.D. x 92.1mm, with deactivated wool 5/pack
List Price : 219.00 USD

CAPILLARY Quartz Liner for Split Operations with Silanized Glass Wool, 4 x 6.2 x 92.1 Package of 5

CAPILLARY Quartz Liner for Split Operations, with Silanized Glass Wool, for Programmed-Temperature Split/Splitless Inlet System
List Price : 124.00 USD

Zero Dilution Standard Split Splitless Outer Liner

To be used with zero dilution inner liner. The zero dilution liner allows you to achieve lower detection limits, sharpen peak shape, and increase throughput for many routine analyses.
List Price : 86.00 USD

Silanized Glass Wool (50 g)

Silanized glass wood is made for use with Automated Thermal Desorber (ATD) 400.
List Price : 78.00 USD

CAPILLARY Quartz Liner for Split Operations with Silanized Glass Wool, 4 x 6.2 x 92.1 Package of 1

CAPILLARY Quartz Liner for Split Operations, with Silanized Glass Wool, for Programmed-Temperature Split/Splitless Inlet System
List Price : 41.00 USD

Zero Dilution Inner Liner

To be used with zero dilution outer liner. The zero dilution liner allows you to achieve lower detection limits, sharpen peak shape, and increase throughput for many routine analyses.
List Price : 47.00 USD

PSS Quartz Split Liner with Silanized Glass Wool, 2 x 4 x 86.2 Package of 1

PSS Quartz Split Liner, with Silanized Glass Wool, for Programmed-Temperature Split/Splitless Inlet System
List Price : 25.00 USD
List Price : 67.00 USD

PSS Quartz Split Liner with Silanized Glass Wool, 2 x 4 x 86.2 Package of 5

PSS Quartz Split Liner, with Silanized Glass Wool, for Programmed-Temperature Split/Splitless Inlet System
List Price : 112.00 USD

Splitless Siltek Liner with Wool 2mm Package of 5

Splitless Siltek Liner with Wool 2mm; 2mm I.D x 6.2mm O.D x 92.1mm length
List Price : 259.00 USD

Liner/Nozzle Replacement Tool for Flame Ionization Detector (FID)

Allows easy removal of glass liners from injector port.
List Price : 60.00 USD

"Liners" 1-50 of 50 Products and Services