Columns

OF

Ensure the best results from your chromatography analysis with our high-performance columns. Choose from our wide selection of HPLC and LC columns as well as GC columns for both your PerkinElmer and non-PerkinElmer chromatography instrumentation.

  • Products and Services

  • Resources, Events & More

Narrow your results
Inner Diameter
  • 0.0 (6)
  • 0.1 (10)
  • 0.2 (176)
  • 0.3 (136)
  • 0.4 (57)
  • 0.5 (95)
  • 1.0 (4)
  • 2.0 (14)
  • 2.1 (163)
  • 3.0 (42)
  • 3.2 (16)
  • 4.0 (50)
  • 4.6 (253)
  • 5.0 (1)
  • 7.8 (1)
Product Family
  • Aquapore (38)
  • Brownlee (43)
  • Brownlee Validated (111)
  • CHOICE (37)
  • Pecosphere (10)
  • Polypore (5)
  • Velocity (19)
  • VeloSep (4)

"Columns" 1-50 of 1102 Products and Services

Sort
Per Page
List Price: 705.00 USD
List Price: 705.00 USD
List Price: 685.00 USD

Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 0.25µm, Temperature Limits: -20 to 310/330°C

PerkinElmer Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 0.25µm, Temperature Limits: -20 to 310/330°C.

List Price: 800.00 USD

Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 0.50µm, Temperature Limits: -20 to 300/320°C

PerkinElmer Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 0.50µm, Temperature Limits: -20 to 300/320°C.

List Price: 800.00 USD

Elite-PONA Dimethylpolysiloxane, Length: 50m, Inner Diameter: 0.20mm, Film Thickness: 0.50µm, Temperature Limits: -60 C to 325/350 C

The Elite-1 columns are 100% dimethyl polysiloxane and come in a variety of sizes to meet your needs.

List Price: 895.00 USD
List Price: 766.00 USD

Elite-Q PLOT phase, Length: 30m, Inner Diameter: 0.32mm, Temperature Limits: -60 C to 250 C

Elite-Q PLOT Phase Columns are for analysis of light gases and hydrocarbons.

List Price: 765.00 USD

Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 3.00µm, Temperature Limits: -20 to 280/300°C

PerkinElmer Elite-200, Length: 30m Inner Diameter: 0.53mm, Film Thickness: 3.00µm, Temperature Limits: -20 to 280/300°C.

List Price: 766.00 USD
Conventional-column_320px
List Price: 214.00 USD

Elite-35, Length: 30m, Inner Diameter, 0.53mm, Film Thickness: 1.00µm, Temperature Limits: 40 to 260/280°C

Elite-35 Columns are dimethylpolysiloxane (35% Diphenyl) silica fused columns; the small percentage of phenyl groups imparts selectivity towards aromatic components.

List Price: 732.00 USD

Elite-225, Length: 15m, Inner Diameter: 0.32mm, Film Thickness: 0.25µm, Temperature Limits: 45 to 220/240°C

Elite-225 Columns are fused silica columns coated with phenylmethylpolysiloxane (50% cyanopropylphenyl).

List Price: 386.00 USD

Elite-Q PLOT phase, Length: 30m, Inner Diameter: 0.53mm, Temperature Limits: -60 C to 250 C

Elite-Q PLOT Phase Columns are for analysis of light gases and hydrocarbons.

List Price: 861.00 USD
Brownlee MPLC cartridges

Reversed Phase, RP-8, Spheri-10, C-8, monofunctional, 10µm, 80 A, 3 cm, 2.1 mm i.d. Brownlee MPLC Cartridge Column

A C8 Hydrophobic group bonded to a silica support are used together with a mobile phase of water and organic solvent to perform separation.

List Price: 124.00 USD
List Price: 800.00 USD

Elite-1, Length: 25m, Inner Diameter: 0.32mm, Film Thickness: 0.52µm, Temperature Limits: -60 to 325/350°C

The Elite-1 columns are 100% dimethyl polysiloxane and come in a variety of sizes to meet your needs.

List Price: 651.00 USD

Elite-5, Length: 20m, Inner Diameter: 0.10mm, Film Thickness: 0.40µm, Temperature Limits: -60 to 325/350°C

Elite-5 Columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g. Aroclor mixes), and solvent impurities.

List Price: 691.00 USD
Brownlee SPP
List Price: 701.00 USD

Elite-35, Length: 15m, Inner Diameter, 0.45mm, Film Thickness: 0.85µm, Temperature Limits: 40 to 280/300°C

Elite-35 Columns are dimethylpolysiloxane (35% Diphenyl) silica fused columns; the small percentage of phenyl groups imparts selectivity towards aromatic components.

List Price: 481.00 USD

Elite-Volatiles Specialty phase, Length: 75m, Inner Diameter: 0.45mm, Film Thickness: 2.55µm, Temperature limits -20 C to 260 C

Elite Volatiles Specialty Phase Capillary Columns are for analysis of volatile organic compounds.

List Price: 1430.00 USD

Elite-225, Length: 20m, Inner Diameter: 0.10mm, Film Thickness: 0.10µm, Temperature Limits: 45 to 220/240°C

Elite-225 Columns are fused silica columns coated with phenylmethylpolysiloxane (50% cyanopropylphenyl).

List Price: 589.00 USD

Elite-MWAX, Length: 30m, Inner Diameter: 0.53mm, Film Thickness 1.00µm, Temperature Limits: 20 to 230/240°C

PerkinElmer Elite-MWAX Steel Capillary GC Phases (Bonded), Length: 30m, Inner Diameter: 0.53mm, Film Thickness 1.00mm, Temperature Limits: 20 to 230/240°C

List Price: 773.00 USD
Brownlee MPLC cartridges
List Price: 471.00 USD

GC Columns Velocity-5 30 M x 0.32 mm x 0.25 µm 5% Diphenyl and 95% Dimethyl Polysiloxane

Velocity fused silica columns yield exceptional performance for general GC applications.

List Price: 300.00 USD
List Price: 1071.00 USD

Elite-1, Length: 20m, Inner Diameter: 0.18mm, Film Thickness: 0.18µm, Temperature Limits: -60 to 325/350°C

The Elite-1 columns are 100% dimethyl polysiloxane and come in a variety of sizes to meet your needs.

List Price: 830.00 USD

Elite-5, Length: 20m, Inner Diameter: 0.10mm, Film Thickness: 0.10µm, Temperature Limits: -60 to 325/350°C

Elite-5 Columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g. Aroclor mixes), and solvent impurities.

List Price: 664.00 USD
List Price: 1451.00 USD
Conventional-column_320px

Brownlee HRes PFP Propyl 30 mm 2.1 mm 1.9 µm

LC column with 2 um particle packing materials and a PFPP phase. Suitable for nucleosides, nucleotides, and halogenated compounds.

List Price: 745.00 USD

Elite-35, Length: 30m, Inner Diameter, 0.25mm, Film Thickness: 0.15µm, Temperature Limits: 40 to 280/300°C

Elite-35 Columns are dimethylpolysiloxane (35% Diphenyl) silica fused columns; the small percentage of phenyl groups imparts selectivity towards aromatic components.

List Price: 589.00 USD
List Price: 503.00 USD

Elite-225, Length: 20m, Inner Diameter: 0.18mm, Film Thickness: 0.20µm, Temperature Limits: 45 to 220/240°C

Elite-225 Columns are fused silica columns coated with phenylmethylpolysiloxane (50% cyanopropylphenyl).

List Price: 683.00 USD

Elite-FFAP, Length: 15m, Inner Diameter: 0.53mm, Film Thickness: 1.00µm, Temperature Limits: 40 C to 250 C

Elite-FFAP Columns consist of nitroterephthalic acid modified polyethylene glycol (bonded).

List Price: 461.00 USD

Elite-TPH Specialty phase, Length: 30m, Inner Diameter: 0.45mm, Film Thickness: 1.00µm, Temperature Limits: -10 C to 290 C

Elite-TPH Specialty Phase Capillary Columns are for analysis of total petroleum hydrocarbons.

List Price: 1725.00 USD

Elite-1, Length: 60 m, I.D: 0.32 mm, Film Thickness: 0.10 µm, Temperature Limits: -60 to 325/350°C

Elite-1 capillary columns are fused silica columns coated with a 100% Dimethyl Polysiloxane stationary phase - a highly versatile phase that is extremely rugged, exhibiting long column lifetime, low bleed, and high maximum operating temperatures.

List Price: 1139.00 USD
Conventional-column_320px
List Price: 683.00 USD
List Price: 1159.00 USD

Elite-1, Length: 30m, Inner Diameter: 0.25mm, Film Thickness: 0.25µm, Temperature Limits: -60 to 325/350°C

The Elite-1 columns are 100% dimethyl polysiloxane and come in a variety of sizes to meet your needs.

List Price: 597.00 USD
Conventional-column_320px

Validated Amino 5um; 150 mm x 4.6 mm; 110Å Carbon load 2%; no end cap

Validated conventional columns that are good for normal phase analytes of mono- and disaccharides of similar compounds.

List Price: 594.00 USD

Elite-WAX Polyethylene Glycol, Length: 60m, Inner Diameter: 0.25mm, Film Thickness: 0.50µm, Temperature Limits: 20 to 250/260°C

PerkinElmer Elite-WAX Polyethylene Glycol Series Capillary Columns, Length: 60m, Inner Diameter: 0.25mm, Film Thickness: 0.50mm, Temperature Limits: 20 to 250/260°C

List Price: 1137.00 USD
Conventional-column_320px
List Price: 209.00 USD

Elite-5, Length: 15m, Inner Diameter: 0.53mm, Film Thickness: 1.50µm, Temperature Limits: -60 to 300/320°C

PerkinElmer Elite-5 (5% Diphenyl) Dimethylpolysiloxane Series Capillary Columns, Length: 15m, Inner Diameter: 0.53mm, Film Thickness: 1.50mm, Temperature Limits: -60 to 300/320°C

List Price: 450.00 USD
List Price: 1186.00 USD
Brownlee SPP
List Price: 929.00 USD

Elite-35, Length: 30m, Inner Diameter, 0.32mm, Film Thickness: 0.25µm, Temperature Limits: 40 to 280/300°C

Elite-35 Columns are dimethylpolysiloxane (35% Diphenyl) silica fused columns; the small percentage of phenyl groups imparts selectivity towards aromatic components.

List Price: 656.00 USD
List Price: 489.00 USD

Elite-225, Length: 30m, Inner Diameter: 0.53mm, Film Thickness: 1.00µm, Temperature Limits: 45 to 200/220°C

Elite-225 Columns are fused silica columns coated with phenylmethylpolysiloxane (50% cyanopropylphenyl).

List Price: 732.00 USD

"Columns" 1-50 of 1102 Products and Services

Per Page