PerkinElmer
check quantity

LAMBDA 1050 UV/Vis Spectrophotometer

The LAMBDA 1050 is one of our highest performance UV/Vis system designed for analysis of coatings, high performance glass, solar, and advanced materials and components in both research and manufacturing. The instrument meets and often exceeds industry standards for ultra-high performance, flexibility, and convenience. View the interactive online brochure to see how the LAMBDA 1050 can support your needs.

Part Number L1050
Buy Now

Please enter valid quantity

Please login to add favorites

NULL OR EMPTY CART

You successfully added item(s) to your cart

Detail Information

Increased Scanning Speed

With its high sensitivity, the LAMBDA 1050 can scan faster than ever with no reduction in data quality.

Better Sample Control

The LAMBDA 1050 has been designed with a host of features and accessories to control your sample and ensure the quality of your data, including:

  • The industry’s largest sample compartments for more sample maneuverability and quick installation of various accessories
  • Snap-in integrating spheres to capture diffuse and specular reflectance. Available in 60 and 150 mm, with 8° reflectance and center mount capability
  • Universal Reflectance Accessory with dual Si and InGaAs detectors for automated, precise and reproducible angle adjustments
  • Pol/Depol Drive Unit for automatic control of polarized or depolarized light via PC
  • Internal instrument controlled attenuation from 1 to 0.1%, for high absorbing measurements

Smarter Flexibility

The LAMBDA 1050’s smart modular design and range of snap-in accessories allow you to set up the instrument to suit a variety of needs and configurations, including:

  • Dual Sampling Compartment – The LAMBDA 1050 can be configured with two large sampling compartments for twice the flexibility. Use one for standard reflectance or transmission tests, and the other for more specific customizable applications
  • Universal Reflectance Accessory – Remove the standard detector and snap in this innovative accessory for automatically measuring sample angles
  • General-Purpose Optical Bench – Swap in our GPOB to accommodate larger samples such as lenses, beamsplitters and optics

And the Fastest Setup Time

With so many user-friendly features, the LAMBDA Series offers the industry’s lowest sampling setup time. So, not only can you go where you’ve never gone before, but you can get there the fastest way possible! We also offer a standard validation kit for all of our LAMBDA spectrophotometers.

Specifications

21 CFR Part 11 Compatible Yes
Height 30.0 cm
Interface Tungsten-halogen and Deuterium
Maximum Temperature 35 °C
Minimum Temperature 15 °C
Model Name LAMBDA 1050
Operating Range 175 - 3300 nm
Portable No
Product Brand Name LAMBDA
Warranty 1 year
Weight 77.0 kg
Width 102.0 cm
Resources, Events & More
  • All

Application Note

Directional Reflection Measurements on Highly Reflecting Coatings

We developed spectrophotometry accessories for measuring absolute reflection on highly reflecting samples, not only at near-normal incidences but also at oblique incidences for incident angles up to more than 80 degrees. The accessories are designed for use with a high performance UV/Vis/NIR industrial spectrophotometer and are widely used for the accurate characterisation of mirrors.

PDF 3 MB
Gaining high resolution measurements of optical filters in the NIR range with the LAMBDA 1050 UV/Vis/NIR

The most common measurement for optical filter quality testing is done in transmission mode with the results typically displayed in %T. The measurement maybe performed at any angle of incidence required by the filter design.

PDF 2 MB
High Absorbance Scanning with the PerkinElmer LAMBDA 850 UV/Vis and LAMBDA 950/1050 UV/Vis/NIR Spectrophotometers

In materials research there is sometimes a need to scan high absorbance samples such as laser protection lenses, optical filters, and polarization materials. Such sample types often need to be measured across the whole UV, Vis and NIR ranges of the electromagnetic spectrum.

PDF 2 MB
High Resolution Scanning Performance with the PerkinElmer LAMBDA 1050

The LAMBDA 1050 is the latest in the line of high performance UV/Vis/NIR double monochromator spectrometers offered by PerkinElmer. This instrument incorporates many of the latest technological advances in optical design, including full wavelength range three detector technology, a high resolution, high energy optical system incorporating low stray light holographic gratings, and Indium Gallium Aresnide (InGaAs) sampling modules for enhanced near-infrared (NIR) performance.

PDF 538 KB
Measuring Absorptance (k) and Refractive Index (n) of Thin Films with the PerkinElmer Lambda 950/1050 High Performance UV-Vis/NIR Spectrometers

An optical coating consists of a combination of thin film layers that create interference effects used to enhance transmission or reflection properties for an optical system. How well an optical coating performs is dependent upon the number of factors, including the number of layers, the thickness of each layer and the differences in refractive index at the layer interfaces. The reference grade high performance Lambda 1050 when fitted with the proper accessories becomes an ideal tool for the determination of optical thin film constants.

PDF 3 MB
Reflectance Measurements of Materials Used in the Solar Industry

One of the most common measurements made by the solar energy industry today is quantification of a material’s surface reflectance. These materials are as diverse as metal coatings, semiconductor coatings, anti-reflective coatings on window material.

PDF 636 KB
Simple Method of Measuring the Band Gap Energy Value of TiO2 in the Powder Form using a UV/Vis/NIR Spectrophotometer

The measurement of the band gap of materials is important in the semiconductor, nanomaterial and solar industries. This note demonstrates how the band gap of a material can be determined from its UV absorption spectrum.

PDF 1 MB
Visible Reflectance Spectroscopy of Human Skin: the use of CIE L*a*b* Color Analysis for In Vivo Ethnic Skin Characterization

This schema remains a recognized tool for dermatological research in classifying the response of human skin to visible light for the health and skin care industry. The Fitzpatrick Scale is a modernization of the older Von Luschan’s Chromatic Scale which uses a series of 36 opaque glass tiles to characterize skin color. Figure 1 shows the range of colors for human skin as described by Von Luschan’s tiles. The Fitzpatrick scale then groups these into six skin types: albino, fair, beige, Mediterranean brown, dark brown, and black.

PDF 1 MB

Brochure

The Power of the Sun, Solar Energy Development Solutions

Free, clean and renewable – the power of the sun has unlimited potential to not only help millions of people around the world with limited or no access to electricity, but to also greatly help solve some of our environmental challenges. EcoAnalytix from

PDF 1 MB
Why Limit Yourself, High Performance UV\VIS\NIR Instruments

LAMBDA 1050/950/850 Spectrophotometers are advancing what's possible for your testing capabilities, whether it's measuring the absolute reflectance of coatings at various angles with our LAMBDA™ 950 or analyzing highly absorbing liquids with the LAMBDA 850. Now, with the LAMBDA 1050, we're pushing the limits even more.

PDF 1 MB

Case Study

A Spectroscopic In Vitro Method for the Calculation of Sunscreen SPF Values

Sunscreen protects skin by either absorbing or reflecting the harmful ultraviolet rays, preventing them from reaching the skin. Using sunscreen while exposed to the sun can greatly reduce the chances of damaging skin cells, and developing cancer. For this study the PerkinElmer® Lambda™ 1050 equipped with a 150 mm integrating sphere will be use to collect scatter transmission data for sunscreen placed on a tape substrate. Testing sunscreen on a tape model of human skin to calculate the SPF value is more convenient and economical than testing on human skin.

PDF 2 MB

Field Application Report

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Measurement of Enhanced Specular Reflector Films Using LAMBDA 1050 and URA Accessory 012190_01 FAR

PDF 2 MB

Product Information Bulletin

Regulatory Compliance Certification

Specification Sheet

LAMBDA Flex Series

,LAMBDA Flex Series, LAMBDA Flex Systems, UV/Vis, UV/Vis/NIR, UV Visible, LAMBDA 650, LAMBDA 750, LAMBDA 850, LAMBDA 950, LAMBDA 1050, PbS Sphere, InGaAs Sphere, Diffuse Transmission Sphere, URA, GPOB, ES, Enhanced Software, 21 CFR part 11, Sell Sheet

PDF 500 KB

Technical Note

Full Spectrum, Angle Resolved Reflectance and Transmittance of Optical Coatings Using the LAMBDA 950/1050 UV/VIS/NIR Spectrophotometer with the ARTA Accessory

Full Spectrum Angle Resolved Reflectance and Transmittance of Optical Coating LAMBDA with ARTA 012188_01 TCH

PDF 2 MB
Linearity Measurements in the Visible Region on a LAMBDA 850/950/1050 Using Hellma Linearity Filters

This note demonstrates the use of Hellma® linearity filters to study the linearity of the PerkinElmer® high performance LAMBDA™ instruments (LAMBDA 850, 950 and 1050) in the visible region of the spectrum.

PDF 249 KB

White Paper

Weighing the Benefits and Risks of Nanotechnology White Paper

While some benefits of nanotechnology are undeniable, there are mounting concerns over the potential dangers nanomaterials may pose to human and environmental health. As a global leader in nanomaterial analysis, PerkinElmer offers an array of analytical instrumentation that provides rapid, clear analysis of the most challenging inorganic, organic, carbonaceous, and hybrid nanomaterials.

PDF 1 MB

FAQs

Expand all
To remove the halogen lamp follow the steps below:
  1. Switch off the spectrometer and unplug the line power cord.
  2. Remove the lamp compartment cover.
    Lift vertically from the handhold on the rear of the Lambda 650/850/950. Press down the catch and push the cover off backwards on a Lambda 800/900, or to the left on the other Lambda instruments.
  3. If necessary, remove the lamp baffle by loosening and removing the two screws on the top of the baffle and lifting the baffle vertically upward.
    NOTE: Instruments made prior to January 1, 1997 may have a different type of lamp baffle as shown in Figure 2. This is held in place with the same thumbscrew used to hold the lamp in place. Loosen the thumbscrew just enough to allow the lamp baffle to be removed.
  4. Remove the lamp assembly from the bracket by slackening the thumbscrew and pulling the lamp mount vertically upward.
    Save the thumbscrew, as it will be used with the replacement lamp assembly.
  5. Carefully pull the white ceramic connector from the rear of the halogen lamp.
  1. Unpack the new lamp assembly, taking care to hold it only by the metal mount to prevent fingerprints on the lamp window.
    Fingerprints on the lamp window cause hot spots during lamp operation, which can lead to premature lamp failure.
  2. Attach the thumbscrew to the back of the new lamp assembly.
    Make sure you leave enough room so that you can slide the thumbscrew onto the mounting bracket.
  3. Carefully push the white ceramic connector firmly onto the pins on the base of the lamp.
  4. Slide the new lamp assembly with the thumbscrew attached onto the mounting bracket as shown below.
    Make sure that the notch at the base of the lamp assembly fits securely over the alignment stud on the mounting bracket, so that the lamp mount is flush to the mounting bracket.
  5. If necessary, wipe the lamp window with a soft cloth moistened with alcohol to remove dirt.
    The dirt would otherwise be burned in when the lamp is hot.
  6. Replace the lamp baffle and secure it into place.
  7. Replace the lamp compartment cover and plug the line power cord into the spectrometer.