Avio 500's unique features include:
And for added flexibility, the Avio 500 is available in three configurations, so that you can select the option best suited for your application(s). This configuration of the Avio 500 is equipped with Scott/Cross-Flow sample introduction, suitable for most applications even those requiring hydrofluoric acid.
| 21 CFR Part 11 Compatible | Yes |
|---|---|
| Depth | 84.0 cm |
| Height | 87.0 cm |
| Model Name | Avio 500 Scott/Cross Flow |
| Portable | No |
| Product Brand Name | Avio |
| Warranty | 1 Year |
| Weight | 163.0 kg |
| Width | 76.0 cm |
This work demonstrates the ability of the Avio 500 ICP-OES to meet the USP <232>/<233> criteria for the analysis of orally-administered allergy tablets using Syngistix for ICP Enhanced Security software version 4.0, which provides the tools to help laboratories meet 21 CFR Part 11 compliance.
The London Metal Exchange (LME) issues specifications for a variety of purities for different metals. This work focuses on the analysis of contaminants in nickel with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Primary Nickel” as a guideline for the analytes and required concentrations.
Globally, heavy machinery is used in construction, mining, and a variety of other areas. As the scale of the operations increase, the size, complexity, and cost of the equipment also increase, meaning that breakdowns can be costly, both in equipment repair and lost revenue. As a result, preventive maintenance is paramount. Lubricants are among the key fluids that can be tested, especially the oil used in engines. By monitoring the elemental concentration of the oil or other lubricants (hydraulics, transmission, gear), the status of that compartment can be determined.
This work focuses on the analysis of wastewaters following the guidelines provided in U.S. EPA Method 200.7. The U.S. Environmental Protection Agency (EPA) developed Method 200.7 for the determination of metals and trace elements in waters and wastes by ICP-OES, with the current version being Revision 4.4.1 While the scope of this method allows it to be applied to a variety of sample types, a common application is wastewater analysis.
Ethanol is an important blending component in fuels commonly used in gasoline/petrol. Because of its wide use, it is important to monitor the concentrations of impurities in the ethanol which can negatively impact the performance of the resulting fuel. As a result, standards have been created for the phosphorus (P), sulfur (S), and copper (Cu) content in fuel.
Ethanol analysis by ICP-OES can be challenging both due to volatility and high carbon content. However, with the right choice of sample introduction components and a robust plasma, ethanol can be measured with ease. This work demonstrates the ability of PerkinElmer’s Avio 500 ICP-OES to measure phosphorus, sulfur, copper, and iron in ethanol, leveraging the capabilities of Multicomponent Spectral Fitting (MSF) to eliminate the effect of interferences.
Battery usage is growing rapidly as new uses are found, leading to the development of new battery types, technologies, and materials. Some commonly-used elements in different types of batteries include lithium, manganese, nickel, phosphorus, and zinc, among others. The percentage of these components can range from single digit up to 30%, depending on the battery.
An important factor in obtaining optimum performance is accurately knowing the ratios of the major components, since deviations can negatively affect battery performance, as can the presence of impurities. Therefore, the major components must be measured both with high accuracy and precision, while, at the same time, measuring impurity levels.
ICP-OES is the ideal analytical technique to meet these needs – it has a high tolerance to matrices, yet is capable of high precision and can accurately measure impurities down to the µg/L level. This work demonstrates the ability of PerkinElmer's Avio® 500 ICP-OES to achieve RSDs < 0.1% for matrix elements in simulated battery materials, the result of the instrument's ability to perform true simultaneous measurements.
Download this application note to find out how the Avio 500 ICP-OES can measure elements with both high precision and accuracy while, at the same time, measuring common impurities.
The London Metal Exchange issues specifications for a number of different metals in several grades. This work focuses on the analysis of lead of different purities with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Standard Lead1” as a guideline for the analytes and concentrations.
The analysis of geological materials poses a challenge due to their matrix composition and the sample preparation process required to convert the samples into solution. A commonly used sample preparation technique for geological samples is lithium fusion, which involves mixing the sample with excess lithium borate and heating until the lithium borate melts and dissolves the sample to form a homogenous mass. The resulting solid is dissolved in acid for analysis.
Fusion samples are some of the most punishing samples for an ICP-OES sample introduction system, as they contain high concentrations of Group I elements (such as lithium, sodium, and potassium), which can result in deposits on the nebulizer and injector, resulting in signal drift. In addition, the high concentrations of Group I elements may cause rapid devitrification of the quartz torch, so obtaining accurate results with good precision over longer time intervals is challenging. However, with the proper choice of sample introduction components, these challenges can be overcome.
This work describes the analysis of fusion samples leveraging the PerkinElmer Avio® 500 ICP-OES, with a focus on long-term stability.
The analysis of trace metals in metallurgical matrices also presents a challenge for ICP-OES: spectral interferences. Many elements have a large number of emission lines (i.e. approximately 20,000 for iron), which increases the potential for spectral interferences. This effect is compounded in metallurgical samples, where the matrix element(s) are present at high levels due to the minimal dilutions used.
With a truly simultaneous system, high sensitivity and superior resolution, the Avio® 500 ICP-OES helps your lab accomplish more — even with the most difficult samples — while making the most of your resources.
The Avio 500 provides:
With the Avio 500 ICP-OES, you can do more — faster and more easily. Now is the time to expand your range and extend your resources. Now is the time for the Avio 500 ICP-OES.
Download the brochure to learn more.
The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.
PerkinElmer is equipped to help the grain industry in its quest to feed the world – nutritiously and economically. Our testing and analysis solutions encompass the three primary areas required for complete knowledge of grains and their derivatives – composition, functionality, and safety.
With instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.
This guide provides a basic overview of the most commonly used atomic spectroscopy techniques and provides the information necessary to help you select the one that best suits your specific needs and applications.
All of the consumables and supplies for the PerkinElmer Avio 200 and 500 ICP-OES instruments.
The PerkinElmer Avio 500 ICP-OES instrument is a complete system
PerkinElmer's Syngistix is a workflow-based software designed to offer a harmonized user experience
When performing measurements with ICP-OES, precisions (i.e. relative standard deviations, RSDs) of 1-2% are typical. However, applications exist where greater precision is required, such as in the analysis of precious metals, major components in battery materials, and verification of the matrix composition of samples. A simple way of achieving high precision measurements is through a technique called Continuous Real-Time Simultaneous Internal Standardization (CRTSIS) only available on a truly simultaneous ICP-OES, such as PerkinElmer’s Avio® 500.
Download this technical note to fully understand the true capabilities of the Avio 500’s CRTSIS for your high-precision applications.
PerkinElmer's Avio ICP-OES series incorporates a vertically oriented plasma with complete dual-view
PerkinElmer's patented Flat Plate™ plasma technology for ICP-OES provides several advantages
Baseline and interfering element correction (IEC) are used with ICP optical emission spectrometry
PerkinElmer continues its tradition of excellence and leadership in ICP technology with RF generator