Sort by
1-25 of 312 Products & Services
The first in its category to boast four quads, the NexION® 5000 multi-quadrupole ICP-MS is innovatively designed to meet and exceed the demanding requirements of ultra-trace elemental applications. It delivers exceptionally low background equivalent concentrations and outstanding detection limits, key to ensuring accurate, repeatable results. Plus, it provides superior interference removal, phenomenal stability and unmatched matrix tolerance, for results you can count on. Discover how the NexION 5000 takes ICP-MS performance beyond traditional triple quad.
In addition to boasting four quads, the NexION 5000 is also the proud recipient of three awards: Wiley Analytical Science Award, The Analytical Scientist Innovation Award, and R&D 100 Award.
Its unique single-analyzer, three-quad design, combined with a single gas channel (with upgrade option to multiple channels) and a modernized workflow, come together to offer simple yet effective interference removal, low maintenance, excellent stability, as well as sustainability, all in a streamlined experience – the ideal ICP-MS for day-to-day trace-elemental analyses.
Its unique three-quad design, combined with novel and proven technologies, including the second-generation Triple Cone Interface with OmniRing™, come together to offer outstanding sensitivity, superior interference removal, excellent stability, unmatched matrix tolerance, high throughput/greater uptime, as well as sustainability and low cost of operation.
This Injector Support Adapter is for use with ELAN®/NexION® 300/350 ICP-MS series instruments. It is designed for Non-Ball Joint Injectors.
This MEINHARD™ Quartz Nebulizer, with 0.5 mL/min uptake rate, is for use with NexION® 300/350 ICP-MS series instruments. The MEINHARD™ Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%).
This Injector Support Adapter O-Ring, 9.25 mm I.D. and 1.78 mm width, is for use with ELAN® and NexION® 300/350 ICP-MS series instruments. It is designed for use with both the Twist Type Torch Injector Support Adapter and the Cassette Type Torch Injector Support Adapter.
This Torch Injector Support Adapter is for ELAN®/NexION® 300/350 ICP-MS series instruments. It is designed for use with Quartz Ball Joint Injectors.
This MicroFlow PFA Nebulizer, with external 1/4-28 threaded connector and gas line, is for use with NexION® 1000/2000 ICP-MS series instruments. The PFA-ST MicroFlow nebulizer is made from high purity, HF resistant PFA. It has an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the diameter of the external capillary or probe.
Multi-Element Standard for ICP-MS Instrument Calibration. Every PerkinElmer standard is supplied with a comprehensive Certificate of Analysis.
This Injector Support Adapter O-Ring, 6.07 mm I.D. and 1.78 mm width, is for use with ELAN® and NexION® 300/350 ICP-MS series instruments. It is designed for use with both the Twist Type Torch Injector Support Adapter and the Cassette Type Torch Injector Support Adapter.
This Steel Hyper Skimmer Screw is for use with NexION 300/350 ICP-MS series instruments.
This MEINHARD™ Glass Nebulizer, with 0.5 mL/min uptake rate, is for use with NexION® 300/350 ICP-MS series instruments. The MEINHARD™ Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%).
This Quartz Baffled Cyclonic Spray Chamber, with included drain fitting, is used with NexION® 300 and 350 ICP-MS series instruments.
This 0-Slot quartz torch is used with ELAN® 5000, 6x00, 9000, DRC II, and DRC-e, and all NexION® 300 and 350 ICP-MS series instruments.
This MicroFlow High Efficiency Nebulizer, with PFA gas line, is for NexION® 1000/2000 ICP-MS series instruments. It is specially designed to convert liquid samples to aerosol at sample liquid flow rates as low as 10 μL/min while minimizing rupture of biological cells.
This threaded spray chamber drain line, with Santoprene™ tubing attachment, is used with NexION® 2000 ICP-MS series instruments.
This Baffled Quartz Cyclonic C3 High Sensitivity Spray Chamber is used with NexION® 1000 and 2000 ICP-MS series instruments. It is an ideal all-purpose spray chamber for non-HF samples and provides excellent sensitivity, stability, and reduced boron blank. This spray chamber is designed for applications requiring low levels of boron and silicon detection and includes a Matrix Gas Port.
This Peripump Union, with male threads and dual flaring, is for use with the NexION® 1000/2000 ICP-MS series instruments. It adapts 10/32 to pump tubing and is for use with internal standard tee.
Sort by
1-25 of 109 Resource Library
Food alteration has been increasing substantially in recent years, leading to substandard products. Therefore, to ensure the health and safety of the consumer, it is essential to characterize foods for toxic and nutritional elements accurately and rapidly, and ICP-MS is the ideal technique for these ...
Fine and specialized chemicals are used throughout the manufacturing process of semiconductor and electronic products, requiring strict control of impurities. Among these impurities, contaminants of inorganic nature can adversely affect device performance and impact the yield of the fabrication proc ...
Nanomaterials are infinitesimal, but do not let their size fool you. Their surface area actually increases at the nanoparticle scale to infuse these miniature building blocks with unique magnetic, mechanical, structural, optical, and electrical properties that are different from the same chemical at ...
Due to rising concerns over the carcinogenic properties of hexavalent chromium (Cr6+) in drinking water, many national and regional water standards are looking to lower the maximum allowable levels of total chromium and hexavalent chromium in potable waters. And in order to assess trace concentratio ...
Nickel-based superalloys are widely used in challenging environments because of their physical properties, which include, but are not limited to, toughness, high heat resistance, high strength-to-weight ratio, and low thermal conductivity. The required properties of state-of-the-art nickel-based sup ...
Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its hig ...
While plant-based foods offer many benefits, they carry some challenges associated with their formulation, nutritional content, and safety. Nutritional and toxic elements need to be routinely monitored in incoming raw materials and finished product, ensuring accurate label claims and compliance with ...
Download this useful flyer for a summary of how our instrumentation can test for safety, performance and composition of your advanced battery materials. Get an overview of solutions and their benefits in materials characterization techniques from FT-IR, ICP-OES, ICP-MS, DSC, TGA, GC-MS and hyphenate ...
Analytical testing labs like yours performing trace-elemental analysis with varied sample types and matrices need to deliver accurate, repeatable results, day in and day out. And that means an ICP-MS you can count on – one that’s easy to use and simple to maintain, for maximum uptime; that helps kee ...
Testing for harmful metal(loid)s that may be included in raw materials, processes, paints and additives used in the manufacturing processes of children's toys has been mandated by the regulation EN 71-3. This regulation recommends specific testing methods and maximum allowable concentrations of leac ...
Carbon is difficult to measure with ICP-MS because of its high ionization potential and its presence in both the argon used to generate the plasma (primarily in the form of CO2, as an impurity) and in reagents, including acids and water. As a result, extremely high backgrounds exist at both of the n ...
The NexION® 5000 ICP-MS, with multi-quadrupole technology and Universal Cell, is able to take full advantage of element reactivity with 100% pure gases by analyzing them as cluster ions at higher masses where no interferences reside, and the background is clean. The Universal Cell, thanks to its qua ...
The MPS 320™ is a versatile microwave digestion oven, with a variety of vessels and configurations available, including the newer MR-85, which auto-vents at 20 bar. Advantages of the MR-85 auto-venting vessels include the lack of consumables, being easy to work with, and increased capacity, which al ...
One of the leading academic research groups involved with the study of the impact of ENPs on the environment is the Colorado School of Mines (CSM), based in Golden, Colorado.
During the production of semiconductor devices, it is crucial to ensure that the silicon wafers are free of contaminants and impurities. The use of high-purity chemicals during the cleaning process is critical to the semiconductor product’s overall quality and performance. Therefore, it is essential ...
For decades, the semiconductor industry has been designing new devices that are smaller, faster and consume less power than their predecessors. To maintain this trend, the critical features of these devices must also become smaller and have fewer defects. The small diameter of a chip’s features requ ...
For labs looking to expand their analytical portfolio to include HPLC-ICP-MS, PerkinElmer's NexSAR HPLC-ICP-MS brings together the inert NexSAR speciation analysis ready HPLC system and the revolutionary NexION ICP-MS in a seamless platform, integrated using Clarity chromatography software.
TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...
Tetramethylammonium hydroxide (TMAH) is a basic solvent widely utilized in the semiconductor industry for photoresist development and lithography applications. The reduction of potential contamination on silicon wafers during the manufacturing processes is crucial as trace-metal, particulate and org ...
Hydrofluoric acid (HF) is widely utilized in the semiconductor industry during the cleaning process of silicon wafers in order to reduce contamination by trace metals, particulates, and organic contaminants which would otherwise alter the functionality of the semiconductors. As such, the use of high ...
Silicon (Si) is the most used semiconductor and is a critical element for producing circuits found in everyday electronics. As more industries utilize semiconductor devices and Si wafers in electronic products and services, there is an increasing demand for Si wafers with minimal impurities due to t ...
Metallic contamination in semiconductor products adversely affects device performance and impacts the yield of the fabrication process. To meet the demand for higher yields and performance in wafer substrates, contamination must be minimized on the wafer surface as well as in the substrate itself. T ...
In semiconductor device fabrication, in an effort to reduce the size of electronic devices and improve the yield of the manufacturing process, chemical-mechanical planarization (CMP) slurries consisting of nanoparticles are now in use. CMP is a process of smoothing surfaces with the combination of c ...
The novel GreenCT™ cooling system is designed to provide a reliable, energy-efficient, cost-effective, and eco-friendly solution for cooling the NexION® 1100/2200 ICP-MS system, making it an ideal choice for laboratories looking to optimize their operations and lower operating costs, while reducing ...
This application note presents a high throughput method evaluating 27 analytes in drinking water following U.S. EPA 200.8 with a 3-5 fold reduction in sample analysis time through the use of the HTS high throughput sample introduction system fully integrated with the NexION® ICP-MS and Syngistix™ fo ...