PerkinElmer
check quantity

NexION 2000B ICP Mass Spectrometer

PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

PerkinElmer received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for laboratories new to ICP Mass Spectrometry, the NexION 2000B ICP-MS features:

  • A dedicated SMARTintro sample-introduction module simplifies operator setup, streamlining your workflows
  • Extended Dynamic Range capabilities provide the ability to detect high-and low-level elements in a single sample run
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000B
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Arsenic Speciation Analysis in Rice Following Method GB 5009.11-2014 to Ensure Safety

Rice represents a dietary staple for over half of the world's population. However, in recent years, concerns have been raised over the presence of high levels of arsenic (As), where this carcinogenic metalloid can be accumulated at levels far exceeding ambient concentrations. Since China is the w ...

PDF 1 MB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep i ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperatur ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that PerkinElmer's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Advantages of a High Throughput Sample Introduction System in the Analysis of Drinking Waters Using ICP-MS (Method 200.8)

This application note presents a high throughput method evaluating 27 analytes in drinking water following U.S. EPA 200.8 with a 3-5 fold reduction in sample analysis time through the use of the HTS high throughput sample introduction system fully integrated with the NexION® ICP-MS ...

PDF 1 MB
Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and ...

PDF 1 MB
Analysis of Drinking and Natural Waters with the NexION 2000 ICP-MS

This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...

PDF 1 MB
Analysis of Rare Earth Elements by Laser Ablation-ICP-MS with the NexION 2000 ICP-MS

With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to ...

PDF 1 MB
Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

PDF 555 KB
Analysis of Soils and Waters Following U.S. EPA Method 6020B using the NexION 2000 ICP-MS

Through the years, both industry and analytical instrumentation have advanced. With the development of new chemicals and processes, new pollutants may enter the environment. However, the capabilities of analytical instruments have also increased, allowing the measurement of ever lower levels of envi ...

PDF 2 MB
Boron Isotope Ratio Analysis Using the NexION ICP-MS

Boron (B) is studied for its isotope ratio composition in a range of paleoproxy, geochemical, nuclear, medical, and archeological applications. ICP-MS is recognized as a powerful technique for boron isotope analysis. Quadrupole ICP-MS is versatile and not exclusively dedicated to isotope ratio me ...

PDF 3 MB
Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of Perkin ...

PDF 516 KB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical ...

PDF 1 MB
Determination of Methyl and Inorganic Mercury in Fish with the NexSAR HPLC-ICP-MS Speciation Solution

Consumption of seafood is the primary exposure route of methylmercury for humans, emphasizing the importance of accurately measuring methylmercury in fish. As with all analytical method setup, the determination of methylmercury content in fish has to meet the criteria of modern analytical methodo ...

PDF 1 MB
Determination of Toxic and Other Trace Elements in Baby Foods Using the NexION ICP-MS

For many children around the globe, commercial baby foods are the main source of nutrients and energy, and therefore their quality and safety are critical and must be monitored. In March 2021, the U.S. House of Representatives introduced the “Baby Food Safety Act of 2021” to regulate the presence ...

PDF 699 KB
Determination of Trace Elements in Eye Drops with the NexION ICP-MS

Eye drops are commonly used medications which are available both over-the-counter and as prescriptions in various forms. Because eye drops are classified as a parenteral medication and have relatively large daily doses, the inorganic components in eye drops must be present at low concentrations. ...

PDF 475 KB
Digestion, Testing, and Validation of Heavy Metals in Cannabis

Owing to the toxicity of heavy metals, it is increasingly important to test cannabis flowers and other cannabis derivatives so that patient and consumer safety is maintained as the use of cannabis becomes more common. This need has translated into an increasing demand for testing cannabis flowers ...

PDF 1 MB
Extraction of Gold Nanoparticles from Fish Larvae and Soils

Gold nanoparticles (AuNPs) are widely used in industrial and medical applications. They are known to form naturally during the weathering of Au-bearing mineral deposits, as well as the transformation of gold nuggets and particles. In freshwater systems, they bioaccumulate in aquatic organisms, as ...

PDF 1 MB
Improved Analysis of Fluid Inclusions with LA-ICP-MS Using the NexION ICP-MS: Advantages of a Fast-Scanning Quadrupole

The elemental concentration of fluid inclusions in geological samples provides information about geological processes that lead to the formation of ores and minerals. Laser ablation-ICP-MS (LA-ICP-MS) is the preferred technique for measuring elemental concentrations in fluid inclusions due to its ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its ...

PDF 1 MB
Multi-Elemental Analysis of Soils Using the NexION ICP-MS

The elemental analysis of soils is of vital importance not only for agriculture, but also from an environmental perspective. Toxic metals enter soil primarily through pollution and can be taken up directly by humans in various manners, potentially causing acute or chronically toxic responses. The ...

PDF 1 MB
New Research Evaluating Cisplatin Uptake in Ovarian Cancer Cells by Single Cell ICP-MS

Cisplatin, carboplatin, and oxaliplatin are the most widely used of platinum-based cancer chemotherapy drugs in the Western world. Cisplatin's effectiveness is due to its ability to bind to the DNA, resulting in DNA-platinum (Pt) adducts, which bend the DNA. The cells must then repair the DNA damage ...

PDF 2 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of PerkinElmer's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Speciation of Hexavalent Chromium in Children's Toys According to EN 71-3 Category II with the NexSAR HPLC-ICP-MS

Testing for harmful metal(loid)s that may be included in raw materials, processes, paints and additives used in the manufacturing processes of children's toys has been mandated by the regulation EN 71-3. This regulation recommends specific testing methods and maximum allowable concentrations of l ...

PDF 918 KB
Testing and Validation of Various Antacids for Elemental Impurities using the NexION 2000 ICP-MS

The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...

PDF 576 KB

Brochure

A Guide to General USP Chapters

Quality and consistency of medicines is critical to ensuring their identity, strength, and purity is at a safe level for human consumption.

That's why we rely on strict guidelines – to guarantee medications that make it to the shelves are exactly what they claim to be. This guide helps prov ...

PDF 1 MB
Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading ...

PDF 9 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...

PDF 3 MB
Comprehensive and Compliant Solutions for Glass Analysis

It’s clear, glass has a variety of uses, from practical to technological to decorative. In particular, float glass is widely used in architecture, automotive, transportation, photovoltaic, and solar industries.

For glass testing labs around the world, we offer highly accurate and tailored ...

PDF 2 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

PerkinElmer is equipped to help the gr ...

PDF 6 MB
NexION 2000 ICP Mass Spectrometer

Unrivaled ppq detection limits. Unparalleled usability. Finally analysts can have the best of both worlds with the NexION® 2000 ICP-MS, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the e ...

PDF 1 MB
Refinery and Natural Gas Analysis

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is cri ...

PDF 5 MB

Catalog

Atomic Spectroscopy 2018-2019 Consumables & Supplies Catalog

With instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.

PDF 8 MB

Flyer

ISO 17294 Water Analyzer

Built on robust, flexible technology that enables labs to comply with ISO 17294-2, the ISO 17294 Water Analyzer allows you to quickly begin analyzing drinking and surface water samples using a complete, end-to-end workflow, including instrumentation, software, consumables, validated method and su ...

PDF 672 KB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available:

  • Atomic absorption (AA): flame and graphite furnace
  • Inductively coupled plasma optical emis ...

PDF 2 MB
NexION 1000/2000 ICP-MS Preparing Your Laboratory

PerkinElmer ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION 1000/2000/5000 ICP-MS Consumables & Supplies Guide

Look to PerkinElmer for all of your consumables and supplies for your NexION 1000, 2000, or 5000 ICP-MS system.

PDF 3 MB

Poster

Advanced Solutions for Solar Cells

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems he ...

PDF 1 MB

Product Note

High Throughput System for ICP-MS and ICP-OES Product Note

Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining o ...

PDF 1 MB
Syngistix Atomic Spectroscopy Enhanced Security Software Product Note

PerkinElmer’s Syngistix Enhanced Security software for AA, ICP and ICP-MS meets the special needs of highly regulated labs such as those that must comply with the U.S. FDA’s 21 CFR Part 11 regulations.

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - NexION 1000/2000

Product Certificate for the NexION 1000/2000

PDF 98 KB

Technical Note

Advantages of Short Settling Times for Quadrupole-Based ICP-MS Laser Ablation Imaging

Laser ablation-ICP-MS (LA-ICP-MS) has become an increasingly popular tool for imaging due to its ability to provide spatially resolved elemental information at low concentrations. Many aspects need to be considered when setting up an LA-ICP-MS system for imaging. Laser scanning speed, stage accur ...

PDF 2 MB
Advantages of a Novel Plasma Generator for the NexION 1000/2000/5000 ICP-MS Systems

Unlike other ICP-MS systems on the market that utilize conventional 40-MHz or 27-MHz commercially available generators which are typically customized and modified to work with ICP-MS instruments, the NexION® 1000/2000/5000 ICP-MS systems feature a 34-MHz frequency free-running RF g ...

PDF 986 KB
All Matrix Solution System for NexION ICP-MS Platforms

PerkinElmer’s AMS system provides a number of benefits to simplify analysis of high-matrix samples with theNexION family of ICP-MS instruments. By introducing a flow of argon into the spray chamber neck, the aerosol stream is diluted,allowing for more efficient ionization, fewer matrix effects, a ...

PDF 1 MB
PerkinElmer Asperon Spray Chamber-Delivering Intact Individual Cells to ICP-MS Plasma

Discover how the PerkinElmer Asperon Spray Chamber can deliver "intact individual cells" to ICP-MS Plasma.

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information ab ...

PDF 1 MB

Training

Webinars

White Paper

Assessment of Extractables and Leachables Associated with Pharmaceutical Packaging

Extractables and leachables studies are critical for maintaining the quality of your drug product and complying with GMP regulations during drug development and final batch release. Exposure to extractables and leachables could have a detrimental impact on the safety and efficacy of a final drug pro ...

PDF 881 KB
The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hy ...

PDF 683 KB