NexION 2000B ICP Mass Spectrometer | PerkinElmer
PerkinElmer
check quantity

NexION 2000B ICP Mass Spectrometer

PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

PerkinElmer received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for laboratories new to ICP Mass Spectrometry, the NexION 2000B ICP-MS features:

  • A dedicated SMARTintro sample-introduction module simplifies operator setup, streamlining your workflows
  • Extended Dynamic Range capabilities provide the ability to detect high-and low-level elements in a single sample run
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000B
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Arsenic Speciation Analysis in Rice Following Method GB 5009.11-2014 to Ensure Safety

Rice represents a dietary staple for over half of the world's population. However, in recent years, concerns have been raised over the presence of high levels of arsenic (As), where this carcinogenic metalloid can be accumulated at levels far exceeding ambient concentrations. Since China is the worl ...

PDF 1 MB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep into ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperature, ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that PerkinElmer's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Advantages of a High Throughput Sample Introduction System in the Analysis of Drinking Waters Using ICP-MS (Method 200.8)

This application note presents a high throughput method evaluating 27 analytes in drinking water following U.S. EPA 200.8 with a 3-5 fold reduction in sample analysis time through the use of the HTS high throughput sample introduction system fully integrated with the NexION® ICP-MS and Syngistix™ fo ...

PDF 1 MB
Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and ...

PDF 1 MB
Analysis of Drinking and Natural Waters with the NexION 2000 ICP-MS

This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...

PDF 1 MB
Analysis of Rare Earth Elements by Laser Ablation-ICP-MS with the NexION 2000 ICP-MS

With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to me ...

PDF 1 MB
Analysis of SiO2 Nanoparticles in Standard Mode with Single Particle ICP-MS

With the development of nanotechnology and the increased use of nanoparticles (NPs) in numerous products and processes, the need to characterize them has also grown. Nanoparticles come in a wide variety of compositions, with silica dioxide (SiO2) nanoparticles being used in many areas. For successfu ...

PDF 1 MB
Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

PDF 555 KB
Boron Isotope Ratio Analysis Using the NexION ICP-MS

Boron (B) is studied for its isotope ratio composition in a range of paleoproxy, geochemical, nuclear, medical, and archeological applications. ICP-MS is recognized as a powerful technique for boron isotope analysis. Quadrupole ICP-MS is versatile and not exclusively dedicated to isotope ratio measu ...

PDF 3 MB
Comparison of Microsecond vs. Millisecond Dwell Times on Particle Number Concentration Measurements by Single Particle ICP-MS

With the increasing use of nanomaterials in a wide variety of products and processes, the need to measure and characterize them has also grown. Single particle ICP-MS (SP-ICP-MS) was developed specifically for metallic and metal-containing engineered nanoparticles (NPs) and is gaining popularity due ...

PDF 924 KB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical and ...

PDF 1 MB
Determination of Methyl and Inorganic Mercury in Fish with the NexSAR HPLC-ICP-MS Speciation Solution

Consumption of seafood is the primary exposure route of methylmercury for humans, emphasizing the importance of accurately measuring methylmercury in fish. As with all analytical method setup, the determination of methylmercury content in fish has to meet the criteria of modern analytical methodolog ...

PDF 1 MB
Determination of Toxic and Other Trace Elements in Baby Foods Using the NexION ICP-MS

For many children around the globe, commercial baby foods are the main source of nutrients and energy, and therefore their quality and safety are critical and must be monitored. In March 2021, the U.S. House of Representatives introduced the “Baby Food Safety Act of 2021” to regulate the presence of ...

PDF 699 KB
Digestion, Testing, and Validation of Heavy Metals in Cannabis

Owing to the toxicity of heavy metals, it is increasingly important to test cannabis flowers and other cannabis derivatives so that patient and consumer safety is maintained as the use of cannabis becomes more common. This need has translated into an increasing demand for testing cannabis flowers an ...

PDF 1 MB
Direct Determination of Trace Elements in Nickel-Based Superalloys with the NexION 2000 ICP-MS

Nickel-based superalloys benefit from high heat resistance, high melting points, retention of mechanical and chemical properties at high temperatures, and high corrosion resistance, among others, and are therefore widely used in challenging environments, such as aircraft and power generation turbine ...

PDF 916 KB
Measurement of Titanium Dioxide Nanoparticles in Sunscreen using Single Particle ICP-MS

Titanium dioxide (TiO2) nanoparticles are commonly used in sunscreens as part of the formulation to block the sun’s harmful UV rays. As the use of nanoparticles (NPs) in consumer products has increased, concern has risen as to the health and environmental effects of nanoparticles. Since sunscreens c ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its hig ...

PDF 1 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of PerkinElmer's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Quantification of Low Levels of Hexavalent Chromium in Water Using a NexSAR HPLC-ICP-MS

Due to rising concerns over the carcinogenic properties of hexavalent chromium (Cr6+) in drinking water, many national and regional water standards are looking to lower the maximum allowable levels of total chromium and hexavalent chromium in potable waters. And in order to assess trace concentratio ...

PDF 1 MB
Quantification of Nanoparticle Uptake into Cancer Cells using Single Cell ICP-MS

Nanoparticles (NPs) have been of significant interest over the last two decades as they offer attractive benefits for drug delivery to overcome limitations in conventional chemotherapy. Nanoparticles can be engineered to carry both drugs and imaging probes to simultaneously detect and treat cancer. ...

PDF 906 KB
SP-ICP-MS Analysis of Size and Number Concentration in Mixtures of Monometallic and Bimetallic (Core-shell) Nanoparticles

Separating and measuring the physical and chemical properties of monometallic and bimetallic engineered nanoparticles (NPs) is challenging, especially when mixtures of NPs consist of particles of similar size, composition, and especially when present at low concentrations. Fully characterizing suspe ...

PDF 1 MB
Speciation of Hexavalent Chromium in Children's Toys According to EN 71-3 Category II with the NexSAR HPLC-ICP-MS

Testing for harmful metal(loid)s that may be included in raw materials, processes, paints and additives used in the manufacturing processes of children's toys has been mandated by the regulation EN 71-3. This regulation recommends specific testing methods and maximum allowable concentrations of leac ...

PDF 918 KB
Testing and Validation of Various Antacids for Elemental Impurities using the NexION 2000 ICP-MS

The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...

PDF 576 KB

Brochure

Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading met ...

PDF 9 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and ...

PDF 3 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics. PerkinElmer is equipped to help the grain indus ...

PDF 6 MB
Meat and Seafood Testing Solutions

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle. Our commitment ...

PDF 6 MB
NexION 2000 ICP Mass Spectrometer

Unrivaled ppq detection limits. Unparalleled usability. Finally analysts can have the best of both worlds with the NexION® 2000 ICP-MS, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatil ...

PDF 1 MB

Catalog

Atomic Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 8 MB

Flyer

ISO 17294 Water Analyzer - Compliance Without Complexity

Built on robust, flexible technology that enables labs to comply with ISO 17294-2, PerkinElmer’s ISO 17294 Water Analyzer allows you to quickly begin analyzing drinking and surface water samples using a complete, end-to-end workflow, including instrumentation, software, consumables, validated method ...

PDF 430 KB
S20 Series Autosamplers

The S20 series is the next generation of high-performance, robust, and agile autosamplers designed specifically for PerkinElmer’s spectroscopy platforms - atomic and molecular. The series is comprised of two autosamplers: the S23 with three racks and the S25 with five racks. They are designed to mee ...

PDF 1 MB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve their ...

PDF 587 KB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available: Atomic absorption (AA): flame and graphite furnace Inductively coupled plasma optical emission spectroscopy (ICP ...

PDF 1 MB
NexION 1000/2000 ICP-MS Preparing Your Laboratory

PerkinElmer ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION ICP-MS Series Consumables & Supplies Guide

Whether looking for sample introduction components or standards, we have the consumables you need to keep your NexION up and running smoothly and efficiently.

PDF 2 MB

Poster

Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...

PDF 1 MB

Product Note

High Throughput System for ICP-MS and ICP-OES Product Note

Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining operation simplicity. The HTS maxi ...

PDF 1 MB
Syngistix Atomic Spectroscopy Enhanced Security Software Product Note

PerkinElmer’s Syngistix Enhanced Security software for AA, ICP and ICP-MS meets the special needs of highly regulated labs such as those that must comply with the U.S. FDA’s 21 CFR Part 11 regulations.

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - NexION 1000/2000

Product Certificate for the NexION 1000/2000

PDF 98 KB

Technical Note

Advantages of Short Settling Times for Quadrupole-Based ICP-MS Laser Ablation Imaging

Laser ablation-ICP-MS (LA-ICP-MS) has become an increasingly popular tool for imaging due to its ability to provide spatially resolved elemental information at low concentrations. Many aspects need to be considered when setting up an LA-ICP-MS system for imaging. Laser scanning speed, stage accuracy ...

PDF 2 MB
All Matrix Solution System for NexION ICP-MS Platforms

PerkinElmer’s All Matrix Solution (AMS) system provides a number of benefits to simplify analysis of high-matrix samples with the NexION family of ICP-MS instruments. It allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to s ...

PDF 1 MB
PerkinElmer Asperon Spray Chamber-Delivering Intact Individual Cells to ICP-MS Plasma

Discover how the PerkinElmer Asperon Spray Chamber can deliver "intact individual cells" to ICP-MS Plasma.

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...

PDF 1 MB
Unlocking Carbon-13 with Single Particle ICP-MS: Feasibility Study for Microplastic Detection

Carbon is difficult to measure with ICP-MS because of its high ionization potential and its presence in both the argon used to generate the plasma (primarily in the form of CO2, as an impurity) and in reagents, including acids and water. As a result, extremely high backgrounds exist at both of the n ...

PDF 1 MB

Training

Webinars

White Paper

Assessment of Extractables and Leachables Associated with Pharmaceutical Packaging

Extractables and leachables studies are critical for maintaining the quality of your drug product and complying with GMP regulations during drug development and final batch release. Exposure to extractables and leachables could have a detrimental impact on the safety and efficacy of a final drug pro ...

PDF 881 KB
The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hygie ...

PDF 683 KB