Avio 500 ICP-OES Oils Configuration

PerkinElmer’s new Avio® 500 is a truly simultaneous, dual view, and compact ICP-OES. It utilizes a vertical plasma and is engineered to handle even the most difficult, high-matrix samples without dilution, delivering productivity, performance, and faster return on investment.

Part Number
Model Name
N0810012
Avio 500 Oils
more
N0810010
Avio 500 Scott/Cross Flow
more
N0810011
Avio 500 Cyclonic/Concentric
more
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Detail Information

Avio 500's unique features include:

  • Vertical Plasma Torch Design: provides 100% matrix tolerance, minimizing sample preparation time.
  • Flat Plate Plasma Technology: delivers a more robust, stable plasma and the lowest argon consumption of any ICP (50% less than other systems).
  • Dual View: optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength.
  • PlasmaShear System: offers maintenance-free, argon-free interference removal.
  • Universal Data Acquisition: enables simultaneous acquisition of all available wavelengths, with virtually no time or storage penalty.
  • Color PlasmaCam: for real-time viewing status evaluation of plasma, injector, and torch during analysis.
  • Syngistix for ICP Software: provides an intuitive, left-to-right, icon-based design; built-in, preset methods for faster, easier operation, requiring minimal training; extensive quality control options, including QC Charting; common software platform across AA, ICP, and ICP-MS.
  • Built-in Radian Remote Monitoring Service, available with Syngistix for ICP software v 4.0 or higher, provides real-time monitoring of your Avio 500 ICP-OES system’s diagnostic parameters, enhancing laboratory productivity.

And for added flexibility, the Avio 500 is available in three configurations, so that you can select the option best suited for your application(s). This configuration of the Avio 500 is ideal for organic analysis applications such as the Caterpillar® S.O.S. Program and ASTM® methods D4951 and D5185.

 

Specifications

21 CFR Part 11 Compatible Yes
Depth 84.0 cm
Height 87.0 cm
Model Name Avio 500 Oils
Portable No
Product Brand Name Avio
Technology Type Atomic Spectroscopy
Warranty 1 Year
Weight 163.0 kg
Width 76.0 cm
Resources, Events & More
  • All

Application Note

A Novel Approach to Analysis of In-Service Lubricants for Particle Size/Count and Metal Content

Particle counting is becoming a more routine tool for lubricant condition monitoring and maintenance programs to better identify particles of certain sizes and concentrations that can contribute to machine failure. In-service oils and other lubricants are monitored for particle size similarly to how they are monitored for elemental concentration. An increase in the ISO code (ISO 4406) for particle count or concentration of key wear metals indicates when maintenance is required.

By adding the LPC 500 liquid particle counter in-line with the Avio 500 ICP-OES Oils system, lubricant samples can be analyzed for both wear metals and particles all in one run with results repeatably within one ISO code for the >4, >6 µm sizes for transmission and gear oil. Throughput of 45 seconds on average per sample with less than 1 mL is achieved for both ICP as well as particle counting and sizing, all with the smallest automated particle counting system in the lubricants testing industry.

Download this application note to learn more.

PDF 922 KB
Analysis of Impurities in Nickel with Avio 500 ICP-OES Following London Metal Exchange Guidelines

The London Metal Exchange (LME) issues specifications for a variety of purities for different metals. This work focuses on the analysis of contaminants in nickel with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Primary Nickel” as a guideline for the analytes and required concentrations.

PDF 795 KB
Analysis of In-Service Oils Following ASTM D5185 with the Avio 500 ICP-OES

Globally, heavy machinery is used in construction, mining, and a variety of other areas. As the scale of the operations increase, the size, complexity, and cost of the equipment also increase, meaning that breakdowns can be costly, both in equipment repair and lost revenue. As a result, preventive maintenance is paramount. Lubricants are among the key fluids that can be tested, especially the oil used in engines. By monitoring the elemental concentration of the oil or other lubricants (hydraulics, transmission, gear), the status of that compartment can be determined.

PDF 1 MB
Analysis of Wastewaters Following US EPA 200.7 Using the Avio 500 ICP-OES

This work focuses on the analysis of wastewaters following the guidelines provided in U.S. EPA Method 200.7. The U.S. Environmental Protection Agency (EPA) developed Method 200.7 for the determination of metals and trace elements in waters and wastes by ICP-OES, with the current version being Revision 4.4.1 While the scope of this method allows it to be applied to a variety of sample types, a common application is wastewater analysis.

PDF 1 MB
Impurities in Lead with the Avio 500 ICP-OES Following London Metal Exchange Guidelines

The London Metal Exchange issues specifications for a number of different metals in several grades. This work focuses on the analysis of lead of different purities with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Standard Lead1” as a guideline for the analytes and concentrations.

PDF 1 MB
Using MSF to Resolve Difficult Interferences in Metallurgical Samples with the Avio 500 ICP-OES

The analysis of trace metals in metallurgical matrices also presents a challenge for ICP-OES: spectral interferences. Many elements have a large number of emission lines (i.e. approximately 20,000 for iron), which increases the potential for spectral interferences. This effect is compounded in metallurgical samples, where the matrix element(s) are present at high levels due to the minimal dilutions used.

PDF 1 MB

Brochure

Avio 500 ICP Optical Emission Spectrometer Brochure

With a truly simultaneous system, high sensitivity and superior resolution, PerkinElmer's Avio 500

PDF 1 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

PerkinElmer is equipped to help the grain industry in its quest to feed the world – nutritiously and economically. Our testing and analysis solutions encompass the three primary areas required for complete knowledge of grains and their derivatives – composition, functionality, and safety.

PDF 6 MB
LPC 500-Avio 500 Combined Particle Count & Elemental Analysis of In-Service Lubricants - Interactive Brochure

For in-service oil testing labs challenged with fast turnaround and analytical accuracy, while also controlling operating costs, the wait is over. The new LPC 500 liquid particle counter coupled to the Avio® 500 ICP-OES Oils system enables the same diluted sample to be analyzed for both elements and particle count/size in a single run – a game changer in laboratory workflow that considerably improves operating costs.

  • Two analyses, one run – with single sample preparation
  • Sample-to-sample analysis in 45 seconds
  • Uses less than 1 mL of lubricant sample per analysis
  • Generates less waste for the laboratory
  • PDF 1 MB
    Lubricant Testing Solutions Interactive Brochure

    Increasing demands for efficiency, productivity, data quality, and profitability pose ongoing challenges for lubricant testing labs, like yours. Whether you need to achieve quick turnaround times, minimize downtime, or maximize lab efficiencies, you can rely on PerkinElmer for a comprehensive set of simple-to-use and proven testing solutions to help you achieve accurate results in record time. Learn more about our solutions.

    PDF 1 MB

    Catalog

    Atomic Spectroscopy 2018-2019 Consumables & Supplies Catalog

    With instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.

    PDF 8 MB

    Flyer

    Laboratory Solutions for Lubricant Analysis

    Increasing demands for efficiency, productivity, data quality, and profitability pose ongoing challenges for lubricant testing laboratories, like yours, performing new lubricant or in-service oil analyses.

    Whether you need to achieve quick turnaround times, minimize downtime, or maximize lab efficiencies, you can rely on PerkinElmer as a trusted partner for simple-to-use and reliable testing solutions.

    Partnering with leading global standards organizations and hundreds of oil laboratories, we continually address laboratory needs and ever-changing standards while developing new methods and protocols that conform with ASTM®, regulatory, and customer-defined requirements.

    Download this infographic to learn more about our broad range of proven lubricant testing solutions.

    PDF 542 KB

    Guide

    Atomic Spectroscopy, A Guide to Selecting the Appropriate Technique and System

    This guide provides a basic overview of the most commonly used atomic spectroscopy techniques and provides the information necessary to help you select the one that best suits your specific needs and applications.

    PDF 1 MB
    Avio 200/500 ICP-OES Consumables and Supplies Guide

    All of the consumables and supplies for the PerkinElmer Avio 200 and 500 ICP-OES instruments.

    PDF 3 MB
    Avio 500 ICP-OES Preparing Your Lab

    The PerkinElmer Avio 500 ICP-OES instrument is a complete system

    PDF 2 MB

    Product Note

    Syngistix Cross-Platform Atomic Spectroscopy Software

    PerkinElmer's Syngistix is a workflow-based software designed to offer a harmonized user experience

    PDF 1 MB

    Regulatory Compliance Certification

    Technical Note

    PerkinElmer Avio Series Vertical Dual View ICP-OES

    PerkinElmer's Avio ICP-OES series incorporates a vertically oriented plasma with complete dual-view

    PDF 791 KB
    PerkinElmer's ICP-OES Flat Plate Plasma System

    PerkinElmer's patented Flat Plate™ plasma technology for ICP-OES provides several advantages

    PDF 404 KB
    PerkinElmer's ICP-OES Multicomponent Spectral Fitting

    Baseline and interfering element correction (IEC) are used with ICP optical emission spectrometry

    PDF 287 KB
    PerkinElmer's Solid-State RF Generator for Flat Plate Plasma

    PerkinElmer continues its tradition of excellence and leadership in ICP technology with RF generator