PerkinElmer
check quantity

Avio 200 ICP Optical Emission Spectrometer

The Avio 200 is a compact ICP-OES that combines a vertical plasma design with a host of unique hardware features to handle even the most difficult, high-matrix samples without dilution, delivering a whole new level of performance and flexibility to ICP.

Part Number Avio200
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Avio’s unique hardware features include:

  • RF generator with Flat Plate plasma technology generates a robust, matrix-tolerant plasma using half the argon of other systems;
  • Dual View capability measures every wavelength with no loss of light or sensitivity;
  • Full-wavelength-range CCD array detector measures the wavelength range around the emission line of interest—simultaneously—for superior precision.

The smallest ICP on the market, the Avio 200 offers efficient operation, reliable data, and low cost of ownership by delivering:

  • The lowest argon consumption of any ICP: only 9 L/min, compared to 21 L/min required by other systems
  • The fastest ICP startup: spectrometer ready in just 10 minutes from power on
  • Superior sensitivity and resolution for all elements of interest
  • Extended linear range

And for added flexibility, the Avio 200 is available in two configurations, so that you can choose the nebulizers and spray chambers best suited for your applications: Scott/Cross Flow or Cyclonic/Meinhard®

Plus, Avio 200's unprecedented performance comes with unparalleled ease-of-use. Its unique hardware features combine with the industry's most intuitive software to make multi-element measurements as easy as single-element analyses. Syngistix for ICP Software provides:

  • Left-to-right, workflow-based design
  • Built-in, preset methods for faster, easier operation, requiring minimal training
  • Extensive quality control options, including QC Charting

Specifications

21 CFR Part 11 Compatible Yes
Height 81.0 cm
Portable No
Product Brand Name Avio
Warranty 1 Year
Weight 100.0 kg
Width 65.0 cm
Resources, Events & More
  • All

Application Note

Analysis of Aluminum Alloys with the Avio 200 ICP-OES Following London Metal Exchange Guidelines

Due to its unique characteristics, aluminum (Al) is used in a wide variety of commercial and industrial applications. Its utility can be further enhanced by combining it with other metals to create aluminum-based alloys, where the non-aluminum additives can make up to 15% of the total alloy, by weight.

Because of its popularity and multiple compositions, the London Metal Exchange (LME) lists four different specifications for Al alloy compositions. In these specifications, silicon, copper, zinc, and iron are considered major additions, as they are mostly greater than 1% composition by weight. Therefore, these four elements must be determined with greater accuracy (± 2%) than the others.

This work describes the determination of additives to Al in aluminum alloys at the LME specifications using the Avio® 200 hybrid scanning ICP-OES, an ideal choice for labs performing this application thanks to its charge-coupled device (CCD) detector, providing simultaneous background and analyte measurement, important when dealing with complex matrices, such as alloys.

PDF 1 MB
Analysis of Impurities in Aluminum with the Avio 200 ICP-OES Following London Metal Exchange Guidelines

Due to aluminum’s varied uses and popularity, there are many grades available. The London Metal Exchange (LME) lists specifications for two commonly-used aluminum (Al) purities: 99.5% and 99.7%1, with each having up to six inorganic impurities specified. ICP-OES is the best technique for measuring these impurities at these levels due to its ability to easily handle high-matrix samples and simplicity of operation.

This work describes the analysis of impurities in Al at the LME specifications using the Avio® 200 hybrid scanning ICP-OES, an ideal choice for this application – its optical design provides excellent light throughput, essential for measuring lower concentrations with shorter analytical times, plus, its charge-coupled device (CCD detector) provides simultaneous background and analyte measurement, important for samples such as metal matrices.

PDF 1 MB
Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES

With heavy machinery, it is important to assess its status during operation to prevent breakdowns and costly repairs. A key aspect is monitoring the status of the oil or lubricants used to lubricate various components such as engines, transmissions, gearboxes and many other important areas: if the oil degrades too much or becomes highly contaminated, it can damage various components. Because of its importance, ASTM created a method for the analysis of in-service oils: method D5185.

PDF 960 KB
Analysis of Micronutrients in Fruit Juice Using the Avio 200 ICP-OES

For food manufacturers and processors, it is important to be able to quantify the content of food products, including micronutrients, for both safety and quality reasons along with regulatory label-claim requirements, and ICP-OES is generally favored in a multi-element analytical environment with detection capabilities appropriate for nutritional analysis.

This work focuses on the analysis of micronutrients in a variety of commercial juice products using PerkinElmer's Avio® 200 hybrid-scanning ICP-OES with sample preparation performed using a PerkinElmer Titan MPS Microwave Sample Preparation System.

PDF 2 MB
Analysis of Micronutrients in Milk Using the Avio 200 ICP-OES

With its great importance, milk is available in several different forms: fresh, boxed (ultraheat treated), powdered, and evaporated. The most commonly consumed form varies globally, being dependent on factors such as geography, culture, and climate. For milk producers, internal quality control and the possibility of external monitoring provide strong incentives for the ability to quickly, accurately, and easily monitor nutrients in their products.

PDF 1 MB
Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES

When blending base oils and additives for use as lubricants, it is important to know and control the concentrations of certain elements for optimal performance and longer engine life. This work will focus on the analysis of additives in new oils using PerkinElmer’s Avio™ 200 ICP Optical Emission Spectrometer (ICP-OES), which overcomes limitations of other ICP-OES systems and X-ray analyses.

PDF 760 KB
Analysis of SiO2- and TiO2-Containing Medications Using ICP-OES Following USP 232/233 Guidelines with Software Designed to Aid in 21 CFR Part 11 Compliance

This work demonstrates the ability of the Avio 200 ICP-OES to meet the USP <232>/<233> criteria for Class 1 and 2A elements in tablets containing TiO2 or SiO2 as excipients using Syngistix for ICP Enhanced Security software version 4.0 for 21 CFR Part 11 compliance.

PDF 1 MB
Analysis of Trace Elements in Fertilizer with the Avio 200 ICP-OES

The production of fertilizer is a key industry for a country's agricultural sector, with the main benefit of increasing crop productivity. The primary elements of interest in fertilizers are categorized into four classes: primary nutrients, secondary nutrients, micronutrients, and trace elements. Although a variety of techniques may be used for the measurement of trace elements in fertilizer, ICP-OES offers the best combination of cost, simplicity, ruggedness and accuracy, and also has a dynamic range which is appropriate for the concentrations expected in fertilizer samples.

This work demonstrates the ability of PerkinElmer's Avio® 200 hybrid-scanning ICP-OES to meet Thai regulatory limits for trace elements in fertilizers through the analysis of reference materials.

PDF 982 KB
Compendium - Reliable Methods for Nutritional & Toxic Analysis of Breakfast Foods

Breakfast is an important meal in providing essential nutrients to keep your energy levels up throughout the day. How do we ensure the food and beverages we consume are healthy, nutritious and safe? Following is a collection of application notes highlighting solutions that will help you identify micronutrients in milk, cereal, juice and fresh and dried fruits as well as toxic metals in tea, dairy products and apple juice to ensure safety of your breakfast foods.

PDF 15 MB
Early Detection of Chloride in 3-MCPD Precursors in Palm Oil through the Analysis of Chloride in Edible Oil with the Avio 200 ICP-OES

During the production of palm oil, 3-MCPD forms from the reaction of acylglycerol with the chloride ion (Cl-). 3-MCPD is a potentially carcinogenic compound, with a tolerable daily intake of 2 µg/kg of bodyweight. As a result, the palm oil industry limits the 3-MCPD concentration to less than 10 mg/kg.

Because 3-MCPD only forms in the presence of Cl-, removal of free Cl- is critical. Chloride is introduced from the raw palm fruit, which accumulates Cl- by uptake from the soil, water, and fertilizer. During the processing of the palm fruit, steam is introduced to remove as much Cl as possible. However, if all Cl is not removed, 3-MCPD can be formed in further refining steps. Therefore, after initial processing, the crude palm oil (CPO) must be monitored for chloride content.

This work describes the ability to measure chloride extracted from palm oil by ICP-OES, leveraging the unique capabilities of PerkinElmer’s Avio® 200 hybrid-scanning system.

PDF 948 KB
Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

The analysis of soils for elemental contents presents challenges during the sample preparation step. A common method for preparing a soil sample for inorganic elemental analysis involves digesting the soil sample in an acid that is heated to near-boiling to extract the elements for analysis. When using open vessels in heating blocks, this extraction method typically takes four hours or more to complete. The sample must then be centrifuged or filtered to remove solid particles prior to analysis. The use of a microwave digestion system can speed this up significantly by completing the acid digestion in less than 50 minutes.

PDF 1 MB
Meeting the RoHS Directive with Microwave Sample Preparation and the Avio 200 ICP-OES

With the increasing demand for electronics, manufacturers are continually developing new products with enhanced capabilities, and consequently, the lifetime of electronics is becoming shorter as consumers more frequently upgrade to newer, more advanced models. The result is an increasing number of electronics being discarded, with a high likelihood that metals will enter the environment. To address this issue, the Restriction of Hazardous Substances (RoHS) directive implements limits for the levels of toxic metals of greatest concern, which can be present in electronic devices.

This work demonstrates the ability of PerkinElmer’s Avio® 200 hybrid-scanning ICP-OES with the Titan MPS digestion system to rapidly and accurately measure elements in a variety of sample types which fall under the RoHS directive.

PDF 682 KB
The Analysis of Brines with the Avio 200 ICP-OES

The most common form of brines is sodium chloride (NaCl)-based. These are used primarily in the production of chlorine gas (Cl2) via electrolysis and the polymeric membrane cell process, in which brines are passed through an ion-exchange membrane, where the brine is de-chlorinated via electrolysis to produce chlorine gas. This is the most widely used means of producing Cl2 because the membrane cell process consumes the least amount of energy compared to other Cl2 production processes.

The membrane must remain clean, as contamination will poison it. And since replacing the membrane is expensive, it should only be changed when needed – this can be defined by monitoring the elemental concentrations in the brine, particularly elements which can poison the membrane: aluminum, barium, calcium, iron, magnesium, nickel, silicon, and strontium. These elements should be present at less than 0.1 mg/L in the brine, meaning that low concentrations have to be measured accurately.

Brine analysis presents a challenge due to the extremely high levels of total dissolved solids and the low analyte levels. And because of its ability to handle high levels of dissolved solids, ICP-OES is the preferred analytical technique for brine analysis.

This work demonstrates the ability of PerkinElmer’s Avio 200 hybrid-scanning ICP-OES to accurately measure important contaminants at low levels in brines.

PDF 1 MB

Brochure

Avio 200 Inductively Coupled Plasma Optical Emission Spectrometer

Capable of handling even the most difficult, high-matrix samples without dilution, PerkinElmer’s Avio® 200 hybrid-scanning system brings a whole new level of performance and flexibility to ICP. What's more, that unprecedented performance comes with unparalleled ease-of-use. Unique hardware features and the industry’s most intuitive software combine to make multi-element measurements as easy as single-element analyses.

The smallest ICP on the market, Avio 200 offers efficient operation, reliable data, and low cost of ownership by delivering:

  • The lowest argon consumption of any ICP
  • The fastest ICP startup (spectrometer ready in just minutes from power on)
  • Superior sensitivity and resolution for all elements of interest
  • Extended linear range with dual viewing technology
  • Download the brochure to learn more about the unique capabilities and benefits of PerkinElmer's Avio 200 hybrid-scanning ICP-OES.

    PDF 1 MB
    Grain Testing Solutions Brochure

    The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

    PerkinElmer is equipped to help the grain industry in its quest to feed the world – nutritiously and economically. Our testing and analysis solutions encompass the three primary areas required for complete knowledge of grains and their derivatives – composition, functionality, and safety.

    PDF 6 MB
    Meat & Seafood Interactive Brochure

    Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently – all while striving to reduce costs due to market forces. In this brochure you can find a range of solutions across multiple technologies, products, and services that meets or exceeds the testing needs of meat and seafood processors. Our solutions offer more efficiency and increased accuracy and sensitivity for better yields in real time with minimal training.

    PDF 6 MB
    USP <232>/<233> & ICH Q3D Capabilities Brochure

    The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. Pharmacopeia’s (USP) Chapters <232> and <233> on elemental impurities, they redefined how the pharmaceutical and related supply-chain industries will measure, document, and comply with strict new standards to limit the presence of elemental impurities in drug products.

    PerkinElmer provides the tools and processes you need to take control of impurities testing for both drug substances and drug products, providing proven, reliable technology for the identification and quantification of elemental impurities and the accurate measurement of residual solvents in accordance with strict regulatory guidelines.

    Download this brochure to learn more.

    PDF 3 MB

    Catalog

    Atomic Spectroscopy 2018-2019 Consumables & Supplies Catalog

    With instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.

    PDF 8 MB

    Flyer

    S20 Series Autosamplers

    The S20 series is the next generation of high-performance, robust, and agile autosamplers designed specifically for PerkinElmer’s spectroscopy platforms - atomic and molecular. The series is comprised of two autosamplers: the S23 with three racks and the S25 with five racks. They are designed to meet the needs of all types of laboratories requiring:

  • Capacity - up to 270 samples for the S23 and up to 450 samples for the S25 allowing long, unattended runs
  • Speed - intelligent acceleration and deceleration speed in three axes
  • Ease of use - full control through various software platforms: Syngistix (for AA, ICP-OES and ICP-MS), UVWinLab and SpectrumFL
  • PDF 1 MB

    Guide

    Atomic Spectroscopy, A Guide to Selecting the Appropriate Technique and System

    This guide provides a basic overview of the most commonly used atomic spectroscopy techniques and provides the information necessary to help you select the one that best suits your specific needs and applications.

    PDF 1 MB
    Avio 200/500 ICP-OES Consumables and Supplies Guide

    All of the consumables and supplies for the PerkinElmer Avio 200 and 500 ICP-OES instruments.

    PDF 3 MB

    Product Note

    High Throughput System for ICP-MS and ICP-OES Product Note

    Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining operation simplicity. The HTS maximizes productivity by significantly reducing the time required for the sample uptake, stabilization, and washout.

    This valve-driven system is fully integrated with the Syngistix platform, eliminating the need for third-party software. Using a metal-free fluid path, the system quickly delivers the sample to the plasma, providing excellent results. With simple programming and workflow, the NexION ICP-MS and Avio ICP-OES with HTS simplifies method development for high-throughput analyses, allowing you to dramatically increase the number of samples you can analyze per day.

    PDF 1 MB

    Regulatory Compliance Certification

    Technical Note

    Advantages of PerkinElmer's PlasmaShear Technology for ICP-OES

    ICP-OES is a rugged, robust technique capable of analyzing complex matrices containing percent levels of dissolved solids without the need for dilution. Nevertheless, to ensure accurate, robust analyses several challenges must be overcome. Two important obstacles are self-absorption by the plasma and dealing with the dissolved solids which are not vaporized in the plasma. PerkinElmer’s proprietary PlasmaShear technology is a fully integrated and automated interference-removal system that delivers problem-free axial analysis while protecting the optics from corrosion and deposition.

    Learn more about the benefits of PlasmaShear technology, only available on the Avio® series ICP-OES – download the technical note.

    PDF 608 KB
    Avio Series ICP-OES Solid-State RF Generator Technical Note

    PerkinElmer continues its tradition of excellence and leadership in ICP technology with our fourth-generation, free-running solid-state RF generator on the Avio® ICP-OES with maintenance-free Flat Plate plasma technology, using approximately half the argon of traditional helical coil systems.

    PDF 627 KB
    The Avio 200 ICP-OES: A Unique Double-Monochromator Optical System

    PerkinElmer's Avio™ 200 ICP-OES gains its outstanding analytical performance from its novel optical system, including a unique double monochromator, dual backside-illuminated charge-coupled device (DBI-CCD) detector, real-time Dynamic Wavelength Stabiliz

    PDF 247 KB