Sort by
1-25 of 81 Products & Services
This part can be ordered as a replacement part for the Lower Die of the Volatile Sample Pan Sealer Assembly.
This part can be ordered as a replacement part for the Upper Die of the Volatile Sample Pan Sealer Assembly.
The Alumina Liner - 100 mm3 is used to line Alumina sample cups (04190387, 04191290). Qty. 1
The Alumina Sample Cup, 60 mm3 is ideal for experiments requiring a sample to be brought to temperatures higher than 1500°C or when metal samples are being run. Qty. 1
The Gold-Plated Copper Sealing Disks are reusable sealing disks for high pressure capsules. They are compatible with the Stainless Steel and Gold-Plated Stainless Steel High Pressure capsules. Qty. 10 disks
The Specific Heat Kit includes four sapphire disks manufactured to two separate diameters and thicknesses. It also includes a calibration chart listing the specific heat of aluminum oxide in the form of synthetic sapphire.
The Volatile Sample Capsule Cover is made of stainless steel. It has an operating range of -40 to 300°C and a maximum pressure threshold of 24 bar. Qty. 1000
The Stainless Steel Pans, Covers and O-Rings have an operating range of -40 to 300°C, a volume capacity of 60 µL, and a maximum pressure threshold of 24 bar. Includes 1000 each of pans, covers, and o-rings.
When used on the DSC 8000/8500, Diamond DSC and Pyris 1 DSC autosamplers, requires Platinum Lids (B0182981) for the sample and reference furnaces.
The O-Rings Kit for Large Stainless Steel Pans includes 100 O-rings. This product prevents sealed pans from experiencing loss of mass, particularly for experiments requiring a high internal pressure or a large sample. The pans are compatible with the DSC 7/8000/8500/Diamond DSC/PYRIS 1 DSC. Qty. 100 pans
The Stainless Steel Pans, Covers and O-Rings have an operating range of -40 to 300°C, a volume of 60 µL, and a maximum pressure threshold of 24 bar. Includes 20 each of pans, covers, and o-rings.
When used on the DSC 8000/8500, Diamond DSC and Pyris 1 DSC autosamplers, use platinum lids for the sample and reference furnace covers (B0182981).
These Aluminum Covers are vented covers with a pierce hole, 0.05 mm in diameter. They have an operating range of -170 to 600°C. These covers are compatible with the DSC 4/7/PYRIS 1 DSC anayzers. Qty. 400 covers
The Platinum Sample Pans for TGA 8000 and PYRIS 1 TGA includes 5 pans with hooks. For use when gold and graphite pans and covers are not suitable. Used to analyze mineral, soil, and ceramic samples. With this part number, these pans can be ordered as a replacement or spare set. Qty. 5 pans
These Ceramic Sample Pans are made of ceramic and have an attached hook. They come standard in the TGA 8000 Spares Kit, but, they are also compatible with the PYRIS 1 TGA. Qty. 5 pans.
These Copper Sample Pans and Covers have an operating range of -170 to 730°C and a volume capacity of 40 µL. Typically used in applications such as antioxidant testing (O.I.T.), thermoset and thermoplastic glass transitions, and melting point determinations. Included are 200 pans and 200 covers.
These Aluminum Pans and Covers have a volume of 30 µL, an operating range of -170 to 600 °C, and a maximum pressure threshold of 3 bar. These pans and covers can be use with the Universal Crimper (B0139005). Qty. 400 pans and 400 covers.
The Autosampler Platinum Pan Kit includes 5 platinum sample pans with an attached hook. These pans contain the sample in a sealed environment throughout the experiment. Qty. 5 pans.
The Standard Sample Pan Crimper Press is used to crimp covers on standard DSC pans of aluminum, gold, and copper. Its design incorporates a replaceable crimper head to ensure optimal, long-lasting use of this press.
These Aluminum Pans are heat-treated and have an temperature range of -170 to 600°C, a volume capacity of 40 μL and an ambient maximum pressure. They have a diameter of 0.265 mm ± 0.002 and a depth is 0.064 mm ± 0.003. Qty. These pans are compatible with the DSC 4000. Qty. 400 pans
The Aluminum Sample Pans with Quartz Covers have a volume of 12.5 µL, an ambient maximum pressure threshold, and an operating range of -170 to 600°C. These pans and covers are compatible with DSC 6/7/4000/6000/8000/8500/Jade DSC/Diamond DSC/PYRIS 1 DSC/PYRIS 6 DSC analyzers. Qty. 100 each, pans and covers.
Sort by
1-1 of 1 Business Insights