PerkinElmer

Newborn Screening

OF

Use the highest quality reagents available today to screen for core newborn disorders as well as those detected by expanded screening. Our reagents are the industry standard for analytical performance and reliability in detecting congenital diseases that are treatable only when identified during the first days of life.

Products & Services (40)
Filters:
Application
  • Newborn Screening (4)
Product Brand Name
  • GSP® (8)
  • MSMS Kit (2)
  • NeoBase™ (4)
  • NeoLSD™ (2)
Detection Method
  • DELFIA (8)
  • Enzymatic (4)
Sample Type
  • Dried blood spots (1)
Assay Points (200-50,000)
  • 500 (1)
Automation Compatible
  • Yes (1)
Disorders
  • Biotinidase (BTD) Deficiency (3)
  • Congenital Adrenal Hyperplasia (CAH) (2)
  • Congenital Hypothyroidism (6)
  • Cystic Fibrosis (4)
  • Duchenne Muscular Dystrophy (1)
  • Fabry (2)
  • Galactosemia (6)
  • Gaucher (2)
  • Hemoglobinopathies (4)
  • Krabbe (2)
  • Metabolic Disorders (5)
  • MPS-I (2)
  • Niemann-Pick A/B (2)
  • Phenylketonuria (1)
  • Pompe (2)
  • SCID (3)
Format
  • Microplates (1)
Technology Type
  • MSMS (2)

Sort by

1-25 of 40 Products & Services

  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal hTSH kit (12 plate)

    This kit is intended for the quantitative determination of human thyroid stimulating hormone (hTSH) in blood specimens dried on filter paper as an aid in screening newborns for congenital (neonatal) hypothyroidism using the 1235 AutoDELFIA® automatic immunoassay system.
  • NeoLSD MSMS Kit

    NeoLSD MSMS Kit

    The NeoLSD MSMS Kit is intended for the quantitative measurement of the activity of the enzymes acid-β-glucocerebrosidase (ABG), acid-sphingomyelinase (ASM), acid α glucosidase (GAA), β galactocerebrosidase (GALC), α-galactosidase A (GLA) and α-L-iduronidase (IDUA) in dried blood spots (DBS) from newborn babies.
  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal 17α-OHP kit (12 plate)

    This kit is intended for the quantitative determination of human 17-OH-progesterone in blood specimens dried on filter paper as an aid in screening newborns for congenital adrenal hyperplasia (CAH) using the 1235 AutoDELFIA® automatic immunoassay system.
  • Newborn screening kit

    GSP® Neonatal 17á-OH-progesterone kit

    The GSP Neonatal 17α-OH-progesterone assay is intended for the quantitative determination of 17OHP in dried blood spot specimens as an aid in screening newborns for CAH.
  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal IRT kit (12 plate)

    This kit is intended for the quantitative determination of human immunoreactive trypsin(ogen) (IRT) in blood specimens dried on filter paper as an aid in screening newborns for cystic fibrosis using the 1235 AutoDELFIA® automatic immunoassay system.
  • DX-Newborn-screening-kits_320px

    NeoBase Non-derivatized Assay Solutions

    The NeoBase Non-derivatized Assay Solutions are intended for in vitro diagnostic use with the NeoBase Non-derivatized MSMS Kit and the NeoBase Succinylacetone Solution. The product includes NeoBase Flow Solvent and NeoBase Extraction Solution.
  • PerkinElmer

    RESOLVE Hemoglobin kit (135 tests)

    The RESOLVE Hemoglobin Kit use isoelectric focusing (IEF) to detect hemoglobin variants in whole blood, cord blood or blood spot samples.
  • NeoLSD MSMS Kit

    NeoLSD MSMS kit

    The NeoLSD MSMS Kit is intended for the quantitative measurement of the activity of the enzymes acid-β-glucocerebrosidase (ABG), acid-sphingomyelinase (ASM), acid α glucosidase (GAA), β galactocerebrosidase (GALC), α-galactosidase A (GLA) and α-L-iduronidase (IDUA) in dried blood spots (DBS) from newborn babies.
  • 3311-0010 GSP Creatine Kinease MM kit

    GSP Neonatal Creatine Kinase -MM kit

    The GSP Neonatal Creatine Kinase –MM kit is a solid phase, two-site fluoroimmunometric assay based on the direct sandwich technique. Analyte is bound to monoclonal CK-MM specific antibodies. The fluorescence signal is proportional to the analyte concentration in the sample.
  • EnLite 223

    EnLite Neonatal TREC kit, 3 x 384 reactions

    The PerkinElmer EnLite Neonatal TREC kit, 3 x 384 reactions is an in vitro diagnostic product used with the VICTOR EnLite instrument for the semi-quantitative determination of TREC (T-cell receptor excision circle) DNA in blood specimens dried on filter paper.
  • DX-Newborn-screening-kits_320px

    Neonatal Phenylalanine kit (10 plate)

    Neonatal Phenylalanine kits are intended for the quantitative determination of phenylalanine in blood specimens dried on filter paper as an aid in identifying phenylketonuria in newborns.
  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal Thyroxine (T4) kit (12 plate)

    This kit is intended for the quantitative determination of human thyroxine (T4) in bloodspecimens dried on filter paper as an aid in screening newborns for congenital (neonatal) hypothyroidism using the 1235 AutoDELFIA® automatic immunoassay system.
  • DX-Newborn-screening-kits_320px

    Neonatal Biotinidase kit (50 plate)

    Neonatal Biotinidase kit is intended for the semi-quantitative determination of biotinidase activity in blood specimens dried on filter paper as an aid in screening newborns for biotinidase deficiency.
  • DX-Newborn-screening-kits_320px

    DELFIA® Neonatal Thyroxine (T4) kit (10 plate)

    This kit is intended for the quantitative determination of human thyroxine (T4) in blood specimens dried on filter paper as an aid in screening newborns for congenital (neonatal) hypothyroidism.
  • GSP Neonatal hTSH kit 2s

    GSP® Neonatal hTSH kit

    The PerkinElmer GSP Neonatal hTSH assay is used with dried blood spot specimens as an aid in screening newborns for congenital hypothyroidism.
  • DX-Newborn-screening-kits_320px

    NeoGram AAAC Tandem Mass Spectrometry kit

    The Neogram MSMS kit is intended for the quantitative determination of up to 10 clinically significant amino acids and 13 clinically significant acylcarnitines, detecting up to 30 different metabolic diseases from a single dried blood spot sample using the MS/MS tandem mass spectrometer.
  • GSP Neonatal IRT kit

    GSP® Neonatal IRT kit

    The GSP Neonatal IRT assay allows the quantitative determination of IRT from dried blood spot specimens, and is intended as an aid in screening for cystic fibrosis.
  • PerkinElmer

    extendSURE HbFASC Controls

    The Haemoglobin FASC control is intended to be used as a position marker monitor for haemoglobin variant analysis methods and to assess assay reproducibility in the following assay types: ion exchange HPLC, capillary electrophoresis, cellulose acetate and agar/agarose gel electrophoresis and iso-electric focusing.
  • DX-Newborn-screening-kits_320px

    NeoBase Succinylacetone Assay Solution

    The NeoBase Succinylacetone Solution is intended for use with the NeoBase Non-derivatized MSMS Kit for the measurement and evaluation of succinylacetone from newborn heel prick blood samples dried on filter paper.
  • 3046-0010 NeoBase™ 2 Succinylacetone Assay Solution

    NeoBase™ 2 Succinylacetone Assay Solution

    The NeoBase 2 Succinylacetone Assay Solution is intended for in vitro diagnostic use with the NeoBase 2 Non-derivatized MSMS kit (3044-0010) and the NeoBase 2 Non-derivatized Assay Solutions (3045-0010) to extract succinylacetone from blood samples dried on filter paper. Measurement of argininosuccinic acid requires use of NeoBase 2 Succinylacetone Assay Solution.
  • PerkinElmer
  • PerkinElmer

    Neonatal Biotinidase kit (10 plate)

    Neonatal Biotinidase kit is intended for the semi-quantitative determination of biotinidase activity in blood specimens dried on filter paper as an aid in screening newborns for biotinidase deficiency.
  • EnLite 223

    EnLite Neonatal TREC kit, 1 x 384 reactions

    The PerkinElmer EnLite Neonatal TREC kit, 1 x 384 reactions is an in vitro diagnostic product used with the VICTOR EnLite instrument for the semi-quantitative determination of TREC (T-cell receptor excision circle) DNA in blood specimens dried on filter paper.
  • DX-Newborn-screening-kits_320px

    Neonatal Total Galactose kit (10 plate)

    Neonatal Total Galactose kit is intended for the quantitative determination of total galactose (galactose and galactose-1-phosphate) concentrations in blood specimens dried on filter paper as an aid in screening newborns for galactosemia.
  • DX-Newborn-screening-kits_320px

    Neonatal GALT kit (50 plate)

    Neonatal Galactose Transferase (GALT) kits are intended for the semi-quantitative determination of galactose-1-phosphate uridyltransferase (GALT) activity in blood specimens collected onto filter paper, in screening newborns for galactosemia.