PerkinElmer

Applications

OF
Business Insights (126)
Filters:

Filters :

Resource Library
  • Application Note (93)
  • Article (4)
  • Brochure (6)
  • Case Study (2)
  • FAQ (1)
  • Flyer (3)
  • Guide (1)
  • Poster (5)
  • Product Note (3)
  • Specification Sheet (2)
  • Technical Note (4)
  • White Paper (2)

1-12 of 126 Business Insights

Sort by

  • Brochure

    OilExpress 4 Oil Condition Monitoring System

    The OilExpress 4 system adapts to your laboratory’s needs, from dozens to thousands of samples per day. Its modular design makes it possible to scale up your sample throughput or separately utilize the oil dilution capabilities in busy laboratories that are using ICP analysis. The system minimizes your operational costs by reducing instrument downtime, increasing throughput to reduce cost per sample, and offering significant savings from decreased solvent waste.

  • Brochure

    TurboMatrix Thermal Desorbers for Gas Chromatography

    For laboratories analyzing everything from air quality to flavors and fragrances, thermal desorption offers a faster, easier, more cost-efficient way to prepare samples for GC or GC/MS analysis. Ideal for the trace-level measurement of volatile organic compounds (VOCs)—as well as most semi-volatile chemicals—thermal desorption lets you avoid time-consuming, manual, solvent-based sample preparation in favor of a simple, streamlined, automated approach. It also delivers the added benefits of superior throughput and enhanced sensitivity.

  • Brochure

    QSight Pesticides Analyzer Brochure

    Pesticides can adversely affect human health through the food we consume but can also leach into soil and groundwater and impact us through the environment. To keep up with a complex and constantly changing regulatory environment, your pesticide analysis solution needs to keep up with your burgeoning sample load.

  • Brochure

    Lubricants Analysis - Complete Solutions for Your Lab

    With throughput demands continually increasing, and an ongoing need for more detailed sample information, PerkinElmer systems are setting the standard for speed and productivity in all areas of lubricants analysis: 1.) Wear metals analysis, 2.) Oil condition monitoring and 3.) Confirmatory testing. Modular and scalable, each solution can adapt as your needs change—no matter what the size of your organization or the demands of your application

  • Brochure

    The Power of the Sun, Solar Energy Development Solutions

    As the demand for solar power continues to grow, there needs to be a clear focus on different key issues in the life cycle of a solar cell. These issues are: efficiency, durability and cost. Coupling PerkinElmer’s application knowledge and experience together with our product portfolio, we can help manufacturers overcome these obstacles. At PerkinElmer, we’re taking action to ensure the quality of our environment.

  • Brochure

    Clarus 590 and 690 Brochure

    In today’s budget-constrained, yet highly competitive laboratory environments, the samples you’re being asked to analyze – whether food, pharmaceutical, petrochemical, or environmental – are increasingly difficult. But for some labs, having a dedicated GC for every application isn’t an option. For them, a GC that can do it all isn’t just a nice-to have, it’s a necessity

  • Product Note

    Ozone Precursor System

    The analysis of C2 to C12 volatile organic ozone-precursor compounds can present a serious technical challenge to the analytical chemist. Low concentrations in the atmosphere coupled with the need to monitor frequently to assess diurnal variations means that a preconcentration step of the sample before analysis by thermal desorption is required. While the samples can be collected in the field and returned to the laboratory, remote, field-based analysis is desired which allows reduced data turnaround time, minimizes sample collection hardware and permits the presence or absence of VOCs to be correlated with meteorological data. In the field, low-molecular-weight C2 VOCs can be trapped on solid adsorbents if those adsorbents are cryogenically cooled.

  • Product Note

    Rapid, Cost-Effective Oil Condition Monitoring -- Spectrum OilExpress System

    Designed specifically to meet the requirements of the Caterpillar® S.O.SSM program, the JOAP program, and the new ASTM® Methods D7412, D7414, D7415, D7418, Spectrum™ OilExpress is the fastest, most cost-effective Oil Condition Monitoring (OCM) solution for busy test laboratories. OilExpress also uses less than half the solvent required by competing systems, dramatically reducing day-to-day operating costs and making laboratories more competitive.

  • Product Note

    Torion T-9 GC MS

    Although it was built for portability and speed, the low thermal mass (LTM) capillary GC provides equivalent chromatographic resolution and performance to a benchtop system. The miniature size is achieved by replacing a conventional convectively-heated column oven with a low thermal mass (LTM) column bundle with direct-contact electrical resistive heating. LTM GC uses a small diameter, metal capillary GC column, which is bundled with resistive heating and temperature-sensing wires that are braided Superior technology • Small diameter LTM capillary GC for high speed, high resolution separation of chemical analytes • Rapid temperature programming delivers analysis times of under three min. • Sensitive and selective mass-based detection of a wide range of chemicals • Easy to operate with a color touch-screen display and simple navigation buttons Figure 1. The Torion T-9 Low Thermal Mass Capillary GC is fast and operates reliably. Injection Port with Removable Liner LTM Capillary Column Bundle Cooling Fan Electronic Pressure Control GC Electronic Board together with insulator strands. This design provides for greater heating and cooling speeds and very low power consumption

  • Guide

    Guide to Herb & Spice Adulteration Screening Using NIR

    Food fraud and adulteration has become of particular concern to the industry over the past few years following reports of incidents in the media, with herbs and spices identified as one of the key problem areas. NIR spectroscopy used with the method outlined here can provide a rapid screening technique for detecting adulteration in herbs and spices.

  • White Paper

    Weighing the Benefits and Risks of Nanotechnology White Paper

    There is a growing body of evidence showing that there are significant differences between some nanomaterials and their non-nanoscale counterparts. What those differences portend raises many new questions about their potential to cause harm to human health and the environment.

  • White Paper

    White Paper - Mercedes GP Petronas Formula One Team Racing to the Championship With PerkinElmer

    The Fédération Internationale de l’Automobile (FIA) Sporting Regulations requires that gearboxes must be used on the race car for four races. This ruling places a direct emphasis upon the requirement for a method of periodically analyzing the gearbox for an indication of deterioration.

  • Jump to:
Products & Services (8074)
Filters:

Filters :

Product Type
  • Accessories (1308)
  • Consumables (4328)
  • Instruments (125)
  • Reagents (2205)
  • Service Parts (41)
  • Services (1)
  • Software and Informatics (66)
Assay Target
  • 4-1BBL (2)
  • 4EBP1 (4)
  • A1AT (2)
  • Acetyl CoA carboxylase (1)
  • Adiponectin (3)
  • Aflatoxin (2)
  • Agglutinin (soybean) (2)
  • Akt1 (7)
  • Akt1/2 (1)
  • Akt1/2/3 (11)
  • Albumin (5)
  • ALK (3)
  • AMPKα (2)
  • and three open channels (1)
  • ANGPT1 (4)
  • ANGPT2 (2)
  • ANGPTL3 (2)
  • ANGPTL4 (4)
  • ApoA1 (4)
  • ApoB (2)
  • ApoC3 (2)
  • ApoE (4)
  • AST (1)
  • ATF2 (1)
  • Aβ1-40 (3)
  • Aβ1-42 (2)
  • Aβ1-x (1)
  • Aβ40 (3)
  • Aβ42 (1)
  • B7-H5 (2)
  • BACE-1 (2)
  • BAD (2)
  • BCL-2 (2)
  • Bcl2 (2)
  • Beef troponin (2)
  • Beta-2 microglobulin (2)
  • BMP-7 (2)
  • BMP-9 (2)
  • BRCA2 (2)
  • BTK (3)
  • BTLA (2)
  • c-Met (2)
  • c-Myc (2)
  • C-peptide (4)
  • cAMP (1)
  • cardiac Troponin I (1)
  • Cardiac Troponin T (2)
  • Caspase-9 (1)
  • CCL1 (1)
  • CCL18 (1)
  • CCL3 (3)
  • CCL4 (3)
  • CCL5 (3)
  • CCL8 (1)
  • CD117 (2)
  • CD20 (3)
  • CD276 (2)
  • CD28 (2)
  • CD4 (4)
  • CD45RO (1)
  • CD70 (1)
  • CD8 (4)
  • CD80 (3)
  • CD86 (3)
  • Chk-1 (1)
  • Chk-2 (1)
  • Chloramphenicol (2)
  • CHO HCP (2)
  • CHO-P (2)
  • Cofilin (4)
  • COL1A1 (3)
  • Collagen IV (2)
  • Corticosterone (2)
  • Cortisol (3)
  • COX-2 (4)
  • CREB (3)
  • CRP (2)
  • Cry1Ab/1Ac (2)
  • Cry2A (2)
  • CXCL1 (2)
  • CXCL1/GROα (2)
  • CXCL10 (5)
  • CXCL11 (1)
  • CXCL13 (4)
  • CXCL4/PF4 (2)
  • CXCL9 (3)
  • Cyr61 (1)
  • D-dimer (1)
  • E-Cadherin (4)
  • E.coli HCP (2)
  • EGFR (12)
  • eIF2α (4)
  • eIF4E (3)
  • Elk1 (1)
  • ErbB2 (5)
  • ERK1/2 (8)
  • FASL (1)
  • FCGR2A (2)
  • FCGR2B (1)
  • FCGR3A (8)
  • FGF23 (2)
  • Fibrinogen (4)
  • Fibronectin (4)
  • FLT-1 (2)
  • FOXP3 (2)
  • Frataxin (4)
  • FSH (4)
  • FSP1 (2)
  • G-CSF (1)
  • GAD67 (4)
  • Galectin 9 (2)
  • GAPDH (3)
  • GDNF (2)
  • Ghrelin (4)
  • GITR (1)
  • GLP-1 (3)
  • Glucagon (3)
  • GM-CSF (2)
  • Growth Hormone (1)
  • GSK3β (3)
  • HBeAg (1)
  • HBsAg (2)
  • hCG (4)
  • HCV cAg (1)
  • Histone H2A (1)
  • Histone H3 (10)
  • Histone H4 (1)
  • HLA-C (2)
  • HLA-E (2)
  • HO-1 (2)
  • HO-2 (2)
  • Hsp27 (1)
  • HVEM (2)
  • ICAM-1 (3)
  • IFN-λ2 (4)
  • IFNα (5)
  • IFNβ (2)
  • IFNγ (16)
  • IgA (5)
  • IgE (3)
  • IGF1 (7)
  • IGF2 (1)
  • IGFR (2)
  • IgG (12)
  • IgG1 (4)
  • IgG2 (2)
  • IgG2a (1)
  • IgG2b (1)
  • IgG3 (1)
  • IgG4 (2)
  • IgM (6)
  • IKKα (4)
  • IL-1RA (3)
  • IL-23 (2)
  • IL-23A (2)
  • IL-6 (3)
  • IL10 (5)
  • IL11 (2)
  • IL12 (9)
  • IL13 (7)
  • IL15 (1)
  • IL17 (1)
  • IL17A (13)
  • IL17F (4)
  • IL18 (5)
  • IL1α (4)
  • IL1β (10)
  • IL2 (7)
  • IL21 (2)
  • IL22 (3)
  • IL23 (2)
  • IL25 (4)
  • IL31 (2)
  • IL33 (4)
  • IL4 (8)
  • IL5 (4)
  • IL6 (10)
  • IL7 (1)
  • IL8 (6)
  • Influenza A NP (1)
  • INSR (3)
  • Insulin (6)
  • IP10 (6)
  • IκBα (2)
  • JNK1/2/3 (4)
  • JNK1/3 (1)
  • Kappa light chain (4)
  • KIM-1 (1)
  • LAG3 (2)
  • Lambda light chain (4)
  • Laminin (2)
  • LC3B (3)
  • LDH (2)
  • LDLR (1)
  • Leptin (5)
  • MANF (4)
  • MBNL1 (3)
  • MCP2 (1)
  • MEK1 (4)
  • Mesothelin (2)
  • MIP1α (2)
  • MKK3/6 (1)
  • MKK4 (3)
  • MMP-12 (2)
  • MMP-7 (2)
  • MMP1 (1)
  • MMP12 (2)
  • MMP13 (2)
  • MMP2 (1)
  • MMP23 (1)
  • MMP3 (2)
  • MMP7 (2)
  • MMP8 (4)
  • MMP9 (2)
  • mTOR (4)
  • Myeloperoxidase (1)
  • Myoglobin (1)
  • N-cadherin (2)
  • Neprilysin (1)
  • NFκB (7)
  • NGAL (2)
  • Nidogen-1 (3)
  • NNMT (1)
  • Oncostatin M (4)
  • Osteoprotegerin (3)
  • p24 (3)
  • p38 MAPK (5)
  • p53 (7)
  • p62 (1)
  • p70 S6K (7)
  • panCK (2)
  • PCSK9 (3)
  • PD-1 (5)
  • PD-L1 (5)
  • PD-L2 (1)
  • PDGF (2)
  • PDK1 (1)
  • PEG IgM (1)
  • PER.C6 HCP (3)
  • Periostin (1)
  • Perlecan (4)
  • PIGF (2)
  • PIP Collagen (4)
  • pNFH (1)
  • PON1 (2)
  • PON2 (1)
  • Progesterone (1)
  • Protein A (1)
  • PSA (1)
  • PSMA (2)
  • PTEN (4)
  • Residual DNA (4)
  • Residual Protein A (1)
  • S100A4 (2)
  • S6RP (4)
  • SCF (2)
  • SDF1 (2)
  • SHP-1 (2)
  • SHP-2 (1)
  • SHP2 (1)
  • SLP-76 (5)
  • SMAD1 (4)
  • SMAD2 (4)
  • SMAD3 (4)
  • Somatostatin (2)
  • Src (2)
  • STAT1 (7)
  • STAT3 (6)
  • STAT4 (2)
  • STAT5 (5)
  • STAT6 (2)
  • SYK (4)
  • Tau (3)
  • TBK1 (1)
  • TDP-43 (4)
  • Testosterone (2)
  • TFF3 (1)
  • TGF-β1 (2)
  • TIM-3 (2)
  • TIMP1 (2)
  • TIMP2 (2)
  • TNFR1 (4)
  • TNFα (15)
  • Topo IIα (3)
  • tPA (2)
  • Transthyretin (1)
  • TREM2 (2)
  • TrkA (1)
  • TrkB (1)
  • TSH (4)
  • TSLP (4)
  • Utrophin (2)
  • VEGF2 Receptor (4)
  • VEGFR1 (2)
  • Vimentin (2)
  • VISTA (2)
  • Zap70 (4)
  • α-tubulin (3)
  • β-Catenin (1)
  • β-NGF (1)
Target Species
  • Bovine (36)
  • CHO (2)
  • Cynomolgus (4)
  • Human (639)
  • Monkey (2)
  • Mouse (61)
  • Ovine (2)
  • Plant (6)
  • Porcine (16)
  • Rabbit (2)
  • Rat (5)
Application
  • 3D culture (1)
  • Antibody binding (2)
  • Assay plates - Cell culture (23)
  • Assay plates - Fluorescence (39)
  • Assay plates - Luminescence (38)
  • cAMP (27)
  • DNA/RNA Quantitation (1)
  • DNA/RNA Quantitation and QC (5)
  • Drug Discovery & Development (339)
  • Enzymatic (5)
  • Epigenetics (47)
  • High biotin samples (8)
  • Imaging (12)
  • Immunohistochemistry (IHC) (25)
  • In situ hybridization (ISH) (25)
  • In vivo imaging (1)
  • Isotyping (11)
  • Kinase (224)
  • LSC (45)
  • Mass Spectrometer (1)
  • Mass Spectrometry (41)
  • Mobility Shift (36)
  • Molecular Biology (53)
  • Multiplexing (42)
  • Plant Sciences (1)
  • Protein Analysis (12)
  • Protein Analysis & Detection (906)
  • Protein-nucleic acid interactions (5)
  • Protein-protein interactions (104)
  • Radiometric (24)
  • Western blotting (13)
Therapeutic Area
  • Agriculture/Plant (6)
  • Angiogenesis (60)
  • Arthritis (21)
  • Atherosclerosis (17)
  • Autophagy (5)
  • Bacterial infection (17)
  • Biologics/Bioprocess (75)
  • Cancer (187)
  • Cardiovascular (134)
  • Central Nervous System (129)
  • CNS & Neurologic (123)
  • Diabetes (20)
  • Epigenetics (11)
  • Food Testing (6)
  • Gastrointestinal (75)
  • Immune (3)
  • Inflammation (365)
  • Kidney (2)
  • Metabolic (126)
  • Metabolic Disorders (41)
  • Musculoskeletal (1)
  • Obesity (9)
  • Oncology/Cancer (25)
  • Pain (69)
  • Parasympathetic Nervous System (5)
  • Renal (2)
  • Sympathetic Nervous System (2)
  • Vascular disease (5)
  • Virology (5)
Product Brand Name
  • 1/2 AreaPlate (1)
  • Advanced Green (2)
  • AequoScreen (4)
  • AequoZen (5)
  • Alpha (16)
  • Alpha SureFire Ultra Multiplex (33)
  • AlphaLISA (546)
  • AlphaLISA SureFire Ultra (68)
  • AlphaPlex (33)
  • AlphaScreen (18)
  • AlphaScreen SureFire (72)
  • Analytical (18)
  • Analytical DB (10)
  • Ancillary Products (3)
  • Apex (2)
  • Aquapore (20)
  • Aquapore Amino (1)
  • Aquapore Octyl (1)
  • Aquapore ODS (1)
  • Aquapore Phenyl (1)
  • Ari Mist (1)
  • Arnel (5)
  • Asperon (1)
  • AssureID (1)
  • Atomax (67)
  • ATPlite (2)
  • ATPlite 3D (2)
  • Avio (13)
  • AxION (2)
  • BacteriSense (1)
  • BetaPlate Scint (1)
  • Biofluor (2)
  • Bioware Brite (20)
  • britelite (1)
  • Brownlee SPP (32)
  • BTO (1)
  • cAMPZen (1)
  • Capricorn (1)
  • Carbosorb (1)
  • Cat B FAST (2)
  • Cat K FAST (1)
  • CellCarrier (8)
  • Cetac (2)
  • CHOICE (6)
  • Cinnabar (1)
  • Clairion® (2)
  • Clarus (8)
  • Conikal (3)
  • Cross-Flow (2)
  • CulturPlate (4)
  • Custodion® (5)
  • D-Torch (6)
  • DairyGuard (2)
  • DELFIA (25)
  • DropletQuant / LabChip DS (3)
  • DuraMist (4)
  • EasyTag (1)
  • EasyTide (19)
  • EDL (14)
  • Elite (21)
  • Elite-1 (64)
  • Elite-1301 (17)
  • Elite-17 (31)
  • Elite-1701 (30)
  • Elite-17ht (High Temperature) (5)
  • Elite-17ms (9)
  • Elite-1ht (3)
  • Elite-200 (34)
  • Elite-225 (13)
  • Elite-23 (2)
  • Elite-35 (10)
  • Elite-35ms (8)
  • Elite-5 (41)
  • Elite-5 Amine (1)
  • Elite-5 Anime (10)
  • Elite-502.2 (4)
  • Elite-5ht (High Temperature) (3)
  • Elite-5ms (22)
  • Elite-608 (9)
  • Elite-624 (10)
  • Elite-Alumina (3)
  • Elite-BAC (6)
  • Elite-BAC Advantage (1)
  • Elite-Betacyclodextrin (1)
  • Elite-CL Pesticides (11)
  • Elite-Cyclosil (1)
  • Elite-FFAP (8)
  • Elite-Molesieve PLOT Phase (1)
  • Elite-MTBE (2)
  • Elite-PONA (1)
  • Elite-Q PLOT (2)
  • Elite-RX (5)
  • Elite-Siltek (2)
  • Elite-SimDist (2)
  • Elite-TPH (2)
  • Elite-VMS (10)
  • Elite-Volatiles (6)
  • Elite-WAX (29)
  • Elite-WAX ETR (24)
  • Elite-XLB (15)
  • Eluo (2)
  • Emulsifier Safe (1)
  • EN3HANCE (1)
  • Enlightning (1)
  • EnSight (1)
  • EnVision (1)
  • ESI (24)
  • EzyFit (7)
  • EzyLok (2)
  • FIAS (1)
  • Filter-Count (1)
  • FIMS (1)
  • FlashPlate (3)
  • Flo-Scint (2)
  • FMT (3)
  • FolateRSense (1)
  • Frontier (6)
  • G-Platform (2)
  • Gas Purifier (50)
  • GastroSense (1)
  • GemCone (4)
  • GemTip (10)
  • GemTip and Cross-Flow (9)
  • Genhance (4)
  • GFR-Vivo (1)
  • HCA ImagAmp (3)
  • Hionic-Fluor (2)
  • Hyamine (1)
  • HypoxiSense (1)
  • Insta-Fluor (1)
  • Insta-Gel (2)
  • IntegriSense (3)
  • IsoMist (4)
  • IsoPlate (9)
  • IVIS (9)
  • JANUS (3)
  • LabChip EZ Reader (50)
  • LabChip GX (2)
  • LabChip GXII (14)
  • LabChip® (1)
  • LAMBDA (19)
  • LANCE (25)
  • LANCE Ultra (30)
  • LANCE SureLight (6)
  • LANCE Ultra (237)
  • LumaPlate (3)
  • Lumina (150)
  • MEINHARD (26)
  • MeltiLex (2)
  • Membrane Target Systems (113)
  • Merlin MicroSeal (2)
  • MetalFree (1)
  • MicroBeta (2)
  • MicroFlow (20)
  • MicroMist (13)
  • MicroScint (5)
  • Mira Mist (9)
  • MMPSense (3)
  • MonoPhase S (1)
  • NEN (3)
  • NEN Radiochemicals (183)
  • NEN Radiolabeled Ligands (74)
  • neolite (1)
  • NexION (2)
  • OilExpress (1)
  • OilPrep (3)
  • OmniFilter (1)
  • OnPoint (1)
  • Opal (7)
  • OpalMist (8)
  • Opera Phenix (1)
  • Operetta (29)
  • Operetta CLS (9)
  • Operetta CLS AND Opera Phenix (9)
  • Opti-Fluor (3)
  • OptiPhase (1)
  • OptiPlate (8)
  • OsteoSense (3)
  • Packard (13)
  • Pecosphere (9)
  • Peltier (19)
  • pergo (2)
  • PerkinElmer (34)
  • PerkinElmer Advanced Green (1)
  • PermaFluor (2)
  • Pico (5)
  • Pico-Fluor Plus (2)
  • PinAAcle (5)
  • Poly-Pro (1)
  • Polypore (3)
  • PolyScreen (4)
  • ProSense (3)
  • ProxiPlate (3)
  • Quantum (2)
  • RediFect (3)
  • ReninSense (1)
  • ScintiPlate (2)
  • SeaSpray (6)
  • sensilite (2)
  • Slurry (2)
  • Solaris (1)
  • Soluene-350 (1)
  • SOLVABLE (1)
  • SPA Enzymatic Assays (3)
  • SPA Imaging Beads (18)
  • SPA Scintillation Beads (26)
  • Spectrum 10 STD (1)
  • Spectrum 10 TimeBase (1)
  • Spectrum Adulterant Screen (1)
  • Spectrum Touch Developer (1)
  • Spectrum Touch ES Apps Runner (1)
  • Spectrum Two (9)
  • Spectrum Two N (2)
  • SpectrumIMAGE (1)
  • Spheri-10 (6)
  • Spheri-5 (30)
  • Spotlight (4)
  • steadylite plus (1)
  • SuperClear (1)
  • Superhance (1)
  • System 2 (15)
  • Teledyne CETAC (3)
  • Titan (2)
  • TLectinSense (1)
  • Torion® (35)
  • Tracey (1)
  • TruLife (1)
  • TSA (12)
  • TSA Plus (14)
  • TurboMatrix (10)
  • twinlite (2)
  • Ultima Gold (16)
  • ULTIMA Gold (9)
  • Ultima-Flo (3)
  • UniFilter (7)
  • UniFit (9)
  • Validated (24)
  • ValiScreen (77)
  • VeeSpray (1)
  • Velocity-1 (6)
  • Velocity-5 (3)
  • Velocity-Wax (3)
  • Victor (1)
  • ViewLux (1)
  • ViewPlate (18)
  • VisiPlate (3)
  • VivoTag (15)
  • VivoTrack (2)
  • Western Lightning (5)
  • XenoLight (24)
  • Zephyr (1)
Color
  • Amber (8)
  • Black (11)
  • Black Frame/White Well (3)
  • Black/Clear Bottom (23)
  • Blue (21)
  • Clear (60)
  • Gray (12)
  • Green (1)
  • Natural (2)
  • Purple (4)
  • Red (13)
  • Silver (19)
  • White (39)
  • White/Clear Bottom (8)
  • Yellow (6)
Coating Treatment
  • Anti-mouse antibody (2)
  • Anti-mouse IgG (3)
  • Anti-rabbit antibody (2)
  • Anti-rabbit IgG (4)
  • Anti-sheep IgG (1)
  • Collagen (5)
  • Copper (HIS-tag) (2)
  • Copper chelate (2)
  • Glutathione (4)
  • High Bind (8)
  • HIS (2)
  • Nickel chelate (HIS-tag) (2)
  • PDE (2)
  • PDL (5)
  • PEI (14)
  • Poly-L-lysine (2)
  • Poly-lysine (5)
  • Protein A (2)
  • RNA Binding (1)
  • Scintillant (8)
  • Sterile (22)
  • Streptavidin (17)
  • TC-treated (22)
  • ULA (3)
  • Uncoated (1)
  • WGA (17)
  • WGA PEI type A (1)
  • WGA PEI Type B (1)
Material
  • Alumina (21)
  • Alumina Ceramic (1)
  • Aluminum (28)
  • Aluminum/Silicone (5)
  • Amber Glass (11)
  • Amber Polyethelene (1)
  • AMTIR (6)
  • Barex (3)
  • Barex/GF/B (1)
  • Barex/GF/C (1)
  • Barium Fluoride (4)
  • Black Viton (1)
  • Boroscilicate Glass (1)
  • Borosilicate Glass (10)
  • Brass (29)
  • Butyl (5)
  • Butyl (gray) Stopper (2)
  • Calcium Fluoride (17)
  • Ceramic (7)
  • Cesium Iodide (1)
  • Clear Glass (62)
  • Clear Plastic (1)
  • Clear Plastic with Slit (1)
  • Clear Polyethelene (2)
  • Coated ZnSe (2)
  • Copper (2)
  • Corrosion Resistant (3)
  • Corrosion-Resistant - Metal Body (1)
  • CTFE (12)
  • Cyclic Olefin (5)
  • Diamond/ZnSe (1 Reflection) (6)
  • Diamond/ZnSe (3 Reflection) (4)
  • Diamond/ZnSe (9 Reflection) (5)
  • ETFE (1)
  • Fluoropolymer (2)
  • Fused Silica (1)
  • Ge (7)
  • Ge (1 Reflection) (3)
  • Glass (53)
  • Glass Bottom (3)
  • Gold (1)
  • Gold-plated (1)
  • Graphite (11)
  • Graphite/Vespel (9)
  • High Sensitivity - Plastic Body (5)
  • KALREZ (2)
  • KRS-5 (3)
  • KRS-5 (1 Reflection) (3)
  • Lead (2)
  • Magnetic Stirrer Fleas (1)
  • Mercury Cadmium Telluride (1)
  • Metal (12)
  • Metal Body (3)
  • Micro Cell Adapter (1)
  • Nichrome (4)
  • Nickel (5)
  • NIR Quartz SUPRASIL 300 (20)
  • Organics (1)
  • PEEK (38)
  • Peek/PTFE (3)
  • PEEK/PTFE (5)
  • PFA (47)
  • Pharmed (2)
  • Phenolic (1)
  • Plastic Body (3)
  • Platinum (19)
  • Platinum Alloy - Metal Body (1)
  • Polyethylene (2)
  • Polyimide (1)
  • Polymethyl Methacrylate (2)
  • PolyPro (1)
  • Polypropylene (20)
  • Polystyrene (66)
  • Polystyrene/GF/B (1)
  • Polystyrene/GF/C (1)
  • Potassium Bromide (25)
  • PPS (1)
  • PTFE (58)
  • PTFE/Butyl (1)
  • PTFE/Buytl (15)
  • PTFE/Red Rubber (15)
  • PTFE/Silicone (33)
  • PTFE/Silicone (Pre-Slit) (16)
  • PTFE/Silicone/PTFE (4)
  • PVC (70)
  • Pyrex (1)
  • Quartz (61)
  • Quartz Suprasil (1)
  • Quartz SUPRASIL (47)
  • Quartz SUPRASIL (FIAS) (2)
  • Ryton (1)
  • Santoprene (9)
  • Sapphire (16)
  • Silica (3)
  • Silicone (8)
  • SilQ (2)
  • Silver Bromide (2)
  • Sodium Chloride (19)
  • Solva (31)
  • Solvent Flex (6)
  • Solvent Resistant (1)
  • Special Optical Glass (22)
  • Stainless Steel (146)
  • Stainless Steel - Metal Body (1)
  • Teflon (3)
  • Tefzel (2)
  • TFE (1)
  • Thallium Bromide-Iodide (2)
  • Titanium (2)
  • Tygon (1)
  • UV (2)
  • UV Material (4)
  • UV Material Individually Wrapped (1)
  • UVS (1)
  • Vespel (1)
  • Viton (8)
  • Viton® (6)
  • Zinc Selenide (6)
  • ZnSe (6)
Detection Method
  • Absorbance (4)
  • Alpha (796)
  • Chemiluminescent (13)
  • Chromogenic (18)
  • Confocal Imaging (15)
  • DELFIA TRF (24)
  • Filtration (4)
  • Fluorescence (112)
  • Fluorescence Polarization (3)
  • High Content Imaging (15)
  • HPLC Analysis (3)
  • Image-based Cytometry (1)
  • Luminescence (58)
  • MSI (6)
  • Radiometric (457)
  • Time-Resolved Fluorescence (TRF) (327)
  • TR-FRET (274)
  • Transmission (2)
Molecular Modification
  • Acetylation (12)
  • GlcNAc (1)
  • Glycosidation (1)
  • Methylation (25)
  • Phosphorylation (110)
  • Total (1)
  • Unmodified (4)
Receptor Type
  • 5-Hydroxytryptamine (12)
  • 5-Hydroxytryptamine (Serotonin) (23)
  • Acetylcholine (1)
  • Acetylcholine (Muscarinic) (16)
  • Adenosine (14)
  • Adrenergic (13)
  • Adrenoceptors (10)
  • Anaphylatoxin (4)
  • Angiotensin (9)
  • Apelin (2)
  • Benzodiazepine (6)
  • Bombesin (5)
  • Bradykinin (4)
  • Calcitonin (6)
  • Calcium (6)
  • Cannabinoid (8)
  • Chemokine (15)
  • Cholecystokinin (5)
  • Corticotropin-Releasing Factor (1)
  • Dopamine (19)
  • Dopamine Transporter (2)
  • Endothelin (3)
  • Epidermal Growth Factor (2)
  • Formyl Peptide (2)
  • Free Fatty Acid (3)
  • GABA (4)
  • GABAA (6)
  • GABAB (1)
  • Galanin (5)
  • Ghrelin (4)
  • Glucagon (6)
  • Glutamate (7)
  • Glycine (4)
  • Gonadotropin-releasing Hormone (1)
  • Growth Hormone (1)
  • hERG (3)
  • Histamine (10)
  • Insulin (3)
  • Insulin-like Growth Factor (1)
  • Interleukin (1)
  • Leukotriene (3)
  • Melanin-Concentrating Hormone (1)
  • Melanocortin (12)
  • Melatonin (4)
  • Metastin (1)
  • Motilin (1)
  • Muscarinic (10)
  • Neuromedin U (2)
  • Neuropeptide (7)
  • Neuropeptide Y (3)
  • Neurotensin (5)
  • Nicotinic (8)
  • NMDA (1)
  • Norephinephrine (1)
  • Norepinephrine (2)
  • Opioid (25)
  • Orexin (4)
  • Oxytocin (2)
  • Peptide P518 (1)
  • Platelet-Derived Growth Factor (1)
  • Potassium (2)
  • Progestin (1)
  • Prokineticin (1)
  • Prolactin Releasing Peptide (2)
  • Prostanoid (9)
  • Purinergic P2Y (2)
  • Relaxin (3)
  • Retinoic Acid Receptors (1)
  • Serotonin (4)
  • SK channels (1)
  • Somatostatin (11)
  • SVCT1 (1)
  • SVCT2 (1)
  • Tachykinin (7)
  • Thyroid Hormone (3)
  • Thyrotropin Releasing Hormone (1)
  • Thyrotropin-releasing Hormone (2)
  • Transforming Growth Factor (1)
  • TRPC5 (1)
  • Urotensin (2)
  • Vasoactive Intestinal Peptide (3)
  • Vasopressin (12)
  • Vesicular Amine Transporters (VATs) (1)
Assay Validated
  • Binding (213)
  • Calcium Fluorescence (21)
  • Calcium Luminescence (9)
  • cAMP (56)
  • Downstream Phosphorylation (1)
  • GTPγS (54)
  • Inositol Phosphate (15)
Sample Type
  • Biological samples (9)
  • DNA / RNA (4)
  • Enzyme (38)
  • Filter (dissolved) (5)
  • Filter (dry) (9)
  • Filter (wet) (5)
  • Flow cocktail (4)
  • Flow cocktail (ammonium phosphate) (2)
  • Flow cocktail (aqueous gradients) (3)
  • Flow cocktail (water/acetonitrile gradients) (1)
  • Flow cocktail (water/methanol gradients) (3)
  • Gas (CO2) (6)
  • Gas (Radon) (7)
  • Liquid (aqueous) (22)
  • Liquid (organic) (7)
  • Oxidized samples (4)
  • Protein (13)
  • Solid (2)
  • Solid (insoluble) (14)
  • Solid (soluble) (25)
Sample pH
  • 6-8 (15)
  • < 6 (7)
  • > 8 (6)
Antibody Conjugates
  • Anti-6X His (5)
  • Anti-acetyl-lysine (1)
  • Anti-Acetyl-Lysine (1)
  • Anti-bovine IgG (1)
  • Anti-bovine IgG1 (1)
  • Anti-bovine IgG2 (1)
  • Anti-bovine IgM (1)
  • Anti-c-Myc (3)
  • Anti-C-tag (3)
  • Anti-chicken IGY (1)
  • Anti-DIG (2)
  • Anti-DNP (2)
  • Anti-FITC (3)
  • Anti-FLAG (7)
  • Anti-GFP (2)
  • Anti-goat IgG (1)
  • Anti-GST (5)
  • Anti-H3 (C-term) (1)
  • Anti-H3K27ac (2)
  • Anti-H3K27me2 (1)
  • Anti-H3K27me2-1 (1)
  • Anti-H3K27me3 (2)
  • Anti-H3K36me2 (2)
  • Anti-H3K4 (3)
  • Anti-H3K4me1-2 (2)
  • Anti-H3K9/H3K27 (1)
  • Anti-H3K9/K27 (1)
  • Anti-H3K9ac (2)
  • Anti-H3K9me2 (2)
  • Anti-H3R2me (1)
  • Anti-H4K20me1 (1)
  • Anti-H4R3me (2)
  • Anti-HA (3)
  • Anti-HRP (2)
  • Anti-human IgE (1)
  • Anti-human IgG (5)
  • Anti-human IgG1 (2)
  • Anti-human IgG2 (1)
  • Anti-human IgG3 (1)
  • Anti-human IgG4 (2)
  • Anti-MBP (1)
  • Anti-methyl arginine (1)
  • Anti-methyl-Arg (1)
  • Anti-mouse IgA (1)
  • Anti-mouse IgE (1)
  • Anti-mouse IgG (8)
  • Anti-mouse IgG1 (1)
  • Anti-mouse IgG2a (1)
  • Anti-mouse IgG2b (1)
  • Anti-mouse IgG3 (1)
  • Anti-mouse IgM (2)
  • Anti-O-GlcNAc (1)
  • Anti-O-linked-GlcNAc (1)
  • Anti-P-Ser 14-3-3 (1)
  • Anti-P-Tyr-100 (1)
  • Anti-p53K382ac (2)
  • Anti-phospho-4EBP1 (1)
  • Anti-phospho-Acetyl-CoA-Carboxylase (1)
  • Anti-phospho-Crosstide (1)
  • Anti-phospho-glycogen synthase (1)
  • Anti-phospho-Histone H3 (2)
  • Anti-phospho-I?Ba (1)
  • Anti-phospho-MEK1/2 (1)
  • Anti-phospho-p70S6K (1)
  • Anti-phospho-PKC (1)
  • Anti-phospho-PLK (1)
  • Anti-phospho-rpS6 (1)
  • Anti-phospho-serine (1)
  • Anti-phospho-threonine (2)
  • Anti-phospho-Topo IIa (1)
  • Anti-phospho-Tyrosine Hydroxylase (1)
  • Anti-rabbit IgG (7)
  • Anti-rat IgG (2)
  • Anti-sheep IgG (1)
  • Anti-V5 (3)
  • Biotin (1)
  • Glutathione (2)
  • Human Fc-fragment (2)
  • LCA (1)
  • Nickel chelate (2)
  • P-Tyr-100 (1)
  • Protein A (6)
  • Protein G (2)
  • Protein L (1)
  • PT66 (2)
  • PY20 (2)
  • Strep-Tactin (2)
  • Streptavidin (8)
  • Streptavidin/Anti-c-Myc (1)
  • Streptavidin/Anti-DIG (1)
  • Streptavidin/Anti-FITC (1)
  • Streptavidin/Anti-FLAG (1)
  • Streptavidin/Anti-GST (1)
  • Streptavidin/Anti-HA (1)
  • Streptavidin/Anti-mouse IgG (1)
  • Streptavidin/Anti-rabbit IgG (1)
  • Streptavidin/Nickel chelate (1)
  • Streptavidin/Phosphosensor (1)
  • Streptavidin/Protein A (1)
  • Streptavidin/PT66 (1)
  • Streptavidin/PY20 (1)
  • Streptavidin/Unconjugated (1)
  • Unconjugated (4)
Radioisotope
  • Ba-133 (4)
  • C-14 (41)
  • Co-57 (1)
  • H-3 (162)
  • I-124 (1)
  • I-125 (78)
  • I-129 (1)
  • Ni-63 (4)
  • P-32 (41)
  • S-35 (13)
Radionuclide
  • 124I (1)
  • 125I (77)
  • 14C (27)
  • 32P (41)
  • 35S (13)
  • 3H (1)
  • 3H (136)
Volume Capacity
  • 0.22 µm (16)
  • 0.25 mL (1)
  • 0.45 µm (18)
  • 0.5 mL (2)
  • 0.5 µL (8)
  • 0.7 - 3 µL (1)
  • 0.7 - 4 µL (1)
  • 1 Gal (4)
  • 1 L (1)
  • 1 mL (47)
  • 1 µL (2)
  • 1.02 mL (1)
  • 1.2 mL (22)
  • 1.4 mL (9)
  • 1.4 µL (1)
  • 1.5 - 3.0 mL (3)
  • 1.5 L/min (2)
  • 1.5 mL (1)
  • 1.75 mL (6)
  • 10 g (2)
  • 10 mL (6)
  • 10 µL (15)
  • 100 g (31)
  • 100 mL (31)
  • 100 µg/g (1)
  • 100 µL (15)
  • 1000 mL (5)
  • 1000 mL/min (1)
  • 1000 µL (3)
  • 12.5 µL (2)
  • 120 µL (1)
  • 125 mL (177)
  • 13 mm (1)
  • 14 mL (4)
  • 15 L/min (4)
  • 15 mL (46)
  • 150 µL (3)
  • 160 mL/min (2)
  • 160 µL (1)
  • 17.5 mL (5)
  • 18 µL (1)
  • 2 g (1)
  • 2 mL (125)
  • 2 uL (1)
  • 2 µL (2)
  • 2.5 - 4.5 mL (3)
  • 2.5 mL (3)
  • 2.5 µL (1)
  • 2.8 mL (8)
  • 20 mL (32)
  • 20 µL (7)
  • 200 g (23)
  • 200 µL (9)
  • 2000 µL (1)
  • 22 mL (5)
  • 25 mL (7)
  • 25 µL (4)
  • 25-500 µL (2)
  • 250 mL (7)
  • 250 mL/min (2)
  • 250 µL (11)
  • 2500 µL (1)
  • 28 mL (3)
  • 3 - 5 µL (1)
  • 3 L/min (2)
  • 3 mL (71)
  • 3.5 L/min (2)
  • 3.5 mL (11)
  • 30 L/min (5)
  • 30 mL (2)
  • 30 µL (8)
  • 300 µL (6)
  • 35 mL (5)
  • 350 µL (6)
  • 370 µL (1)
  • 390 µL (1)
  • 4 g (1)
  • 4 mL (4)
  • 4.5 mL (1)
  • 40 g (2)
  • 40 µL (7)
  • 400 g (32)
  • 400 µL (3)
  • 454 g (5)
  • 5 Gal (1)
  • 5 L/min (2)
  • 5 mL (10)
  • 5 x 500 mL (1)
  • 5 µL (12)
  • 5.6 mL (3)
  • 50 g (54)
  • 50 mL (31)
  • 50 µL (17)
  • 500 mL (121)
  • 500 mL/min (2)
  • 500 µL (16)
  • 6 L/min (2)
  • 6 mL (63)
  • 6 µL - 10 µL µL (1)
  • 60 µL (4)
  • 600 µL (2)
  • 62 µL (1)
  • 62.5 mL (3)
  • 7 mL (17)
  • 7.5 mL (1)
  • 70 - 550 µL (3)
  • 700 µL (6)
  • 75 mL (1)
  • 750 µL (1)
  • 8 µL (1)
  • 80 µL (1)
Nucleotide
  • ATP (12)
  • CTP (8)
  • dATP (11)
  • dCTP (16)
  • ddATP (6)
  • ddCTP (6)
  • ddGTP (6)
  • ddUTP (6)
  • dGTP (5)
  • dTTP (3)
  • dUTP (9)
  • GTP (6)
  • pCp (2)
  • UTP (15)
Grade
  • Classical (13)
  • Pure (150)
  • Pure Plus (41)
  • Safer (29)
Fluorescent Agent Type
  • Activatable (11)
  • Cell labeling (2)
  • Labeling (15)
  • Targeted (18)
  • Vascular (10)
Fluorophore
  • Coumarin (2)
  • Cy3 (19)
  • Cy3.5 (1)
  • Cy5 (16)
  • Cy5.5 (1)
  • Eu-N1 (11)
  • Eu-N1-ITC (2)
  • Eu-W1024 (51)
  • Eu-W1024-ITC (2)
  • Eu-W1284-Iodoacetamido (1)
  • Eu-W8044 (1)
  • Eu-W8044-DTA (1)
  • Fluorescein (18)
  • Lissamine (1)
  • Opal 520 (5)
  • Opal 540 (3)
  • Opal 570 (4)
  • Opal 570 and Opal 690 (1)
  • Opal 620 (3)
  • Opal 650 (3)
  • Opal 670 (1)
  • Opal 690 (3)
  • R110 (3)
  • R6G (2)
  • ROX (2)
  • Sm-N1 (1)
  • SureLight APC (6)
  • TAMRA (4)
  • Texas Red (4)
  • TMR (5)
  • ULight (29)
Label Position
  • alpha (33)
  • gamma (8)
  • Generally Labeled (6)
  • Nominally Labeled (95)
  • Specifically Labeled (135)
  • Uniformly Labeled (14)
Buffer
  • Aqueous (4)
  • Ethanol : water (1)
  • Ethanol:water (1)
  • HCl (1)
  • Sulfuric acid:ethanol (2)
  • Tricine (25)
  • Tricine with stabilizer and dye (20)
Assay points(200-50,000)
  • 100 (307)
  • 1000 (7)
  • 10000 (299)
  • 300 (2)
  • 500 (615)
  • 5000 (330)
  • 50000 (168)
Assay Target Class
  • Aminoglycan (1)
  • Antibody (46)
  • Collagen (3)
  • Cytokine (213)
  • DNA (4)
  • Fc-receptor (12)
  • GPCR (187)
  • Histone (11)
  • Hormone (44)
  • Ion channel (2)
  • Peptide (22)
  • Phosphoprotein (155)
  • Protein (372)
  • Receptor (2)
  • Small Molecule (2)
  • Transporter (6)
  • Tyrosine Kinase Receptor (1)
Automation Compatible
  • No (25)
  • Yes (1235)
Cap and Carrier Style
  • Crimp Top (63)
  • Screw Top (35)
  • Snap Top (12)
Concentration
  • 0.005 mCi/mL (1)
  • 0.02 mCi/mL (2)
  • 0.05 mCi/mL (5)
  • 0.1 mg (2)
  • 0.1 mCi/mL (14)
  • 0.5 mg (2)
  • 0.55 mCi/mL (2)
  • 1 mg (2)
  • 1 µg/L (2)
  • 1 mCi/mL (27)
  • 1 mm (1)
  • 1 µg/mL (1)
  • 1,000 µg/g (2)
  • 1,000 µg/mL (1)
  • 1,500 µg/g (1)
  • 1.0 - 10 mCi/mL (58)
  • 1.0 - 10 µCi/mL (3)
  • 1.12 mCi/mL (1)
  • 1.14 mCi/mL (1)
  • 1.5 mg (2)
  • 10 mg (2)
  • 10 µg/g (10)
  • 10 µg/L (5)
  • 10 2 µg/L (1)
  • 10 mCi/mL (20)
  • 10 µg/mL (16)
  • 10.2 mCi/mL (1)
  • 10.25 mCi/mL (1)
  • 100 µg/g (11)
  • 100 µg/mL (3)
  • 1000 µg/g (36)
  • 1000 µg/g (1)
  • 1000 µg/mL (177)
  • 10000 µg/mL (17)
  • 11 mCi/mL (5)
  • 1100 µg/mL (1)
  • 12.5 mCi/mL (1)
  • 15 mg (2)
  • 15 µg/g (1)
  • 152 µCi/mL (1)
  • 170.1 µCi/mL (1)
  • 171 µCi/mL (1)
  • 172.5 µCi/mL (1)
  • 173.9 µCi/mL (1)
  • 182 µCi/mL (2)
  • 2 mg (2)
  • 2 µg/L (1)
  • 2 mCi/mL (2)
  • 2 µg/mL (1)
  • 2.93 MBq/mL (1)
  • 20 µg/g (1)
  • 20 mCi/mL (4)
  • 20 µg/mL (2)
  • 200 µg/L (1)
  • 2000 µg/mL (18)
  • 236 µCi (1)
  • 25 µg/g (1)
  • 3 mg (2)
  • 3.06 MBq/mL (1)
  • 3.22 MBq/mL (1)
  • 30 mg (3)
  • 30 µg/g (9)
  • 300 µg/g (8)
  • 31.5 mCi/mL (1)
  • 33.7 µCi (1)
  • 345 µCi/mL (3)
  • 353 µCi/mL (3)
  • 40 mg (2)
  • 40 mCi/mL (2)
  • 41.4 µCi/mL (2)
  • 42.5 µCi/mL (1)
  • 43.3 mCi/mL (1)
  • 45.7 µCi/mL (1)
  • 5 µg/g (1)
  • 5 mCi/mL (2)
  • 5,000 µg/g (1)
  • 50 µg/g (9)
  • 50 µCi/mL (1)
  • 50 µg/g (1)
  • 500 µg/g (11)
  • 5000 µg/g (2)
  • 5000 µg/mL (1)
  • 6 mg (2)
  • 6.05 MBq/mL (1)
  • 70 mg (2)
  • 79.2 µCi/mL (2)
  • 83.8 µCi/mL (1)
  • 85.1 µCi/mL (1)
  • 87.2 µCi/mL (1)
  • 87.4 µCi/mL (1)
  • 87.6 µCi/mL (1)
  • 87.9 µCi/mL (1)
  • 88.5 µCi/mL (1)
  • 900 µg/g (8)
  • 93.2 µCi/mL (1)
  • <1.0 mCi/mL (7)
  • <1.0 µCi/mL (3)
  • <100 µCi/mL (1)
Depth
  • 102.5 mm (8)
  • 12.5 mm (49)
  • 22.5 mm (13)
  • 3.5 mm (6)
  • 30.0 cm (9)
  • 33.0 in (2)
  • 41.0 cm (2)
  • 46.0 cm (1)
  • 49.0 cm (2)
  • 52.5 mm (8)
  • 57.0 cm (3)
  • 585.0 mm (1)
  • 60.0 cm (7)
  • 63.5 cm (1)
  • 69.0 cm (2)
  • 7.5 mm (8)
  • 7.5 mm (2)
  • 838.0 mm (1)
  • 84.0 cm (1)
Experimental Type
  • In vitro (823)
  • In vivo (1)
Film Thickness
  • 0.02 µm (1)
  • 0.05 µm (3)
  • 0.1 µm (30)
  • 0.15 µm (29)
  • 0.18 µm (10)
  • 0.2 µm (7)
  • 0.25 µm (102)
  • 0.3 µm (3)
  • 0.33 µm (17)
  • 0.34 µm (1)
  • 0.4 µm (11)
  • 0.42 µm (13)
  • 0.5 µm (54)
  • 0.52 µm (2)
  • 0.6 µm (1)
  • 0.7 µm (2)
  • 0.83 µm (2)
  • 0.85 µm (18)
  • 1.0 µm (82)
  • 1.12 µm (1)
  • 1.27 µm (6)
  • 1.4 µm (8)
  • 1.5 µm (20)
  • 1.7 µm (3)
  • 1.8 µm (8)
  • 10.0 µm (4)
  • 2.0 µm (4)
  • 2.55 µm (13)
  • 20.0 µm (1)
  • 3.0 µm (21)
  • 4.25 µm (4)
  • 5.0 µm (8)
  • 50.0 µm (1)
Format
  • Filtermat (2)
  • Microplates (958)
  • Roll (6)
  • Sheet (4)
  • Slides (25)
  • Tubes (12)
Host Cell
  • 1321N1 (11)
  • A431 (1)
  • A9 (1)
  • CHO-DHFR(-) (1)
  • CHO-K1 (138)
  • HEK293 (41)
  • HT29 (1)
  • K562 (1)
  • L Cells (1)
  • MDA-MB-435S (1)
  • MDCK (2)
  • U373 (1)
  • UC11 (1)
Imaging Modality
  • Bioluminenscence (40)
  • Chemilumiluminescence (2)
  • Fluorescence (58)
  • High Content (2)
  • microCT Imaging (2)
  • Optical Imaging (12)
  • PET Imaging (2)
Inner Diameter
  • 0.0 mm (1)
  • 0.0 mm (2)
  • 0.02 in (1)
  • 0.1 mm (12)
  • 0.11 mm (7)
  • 0.15 mm (13)
  • 0.17 mm (1)
  • 0.18 mm (4)
  • 0.19 mm (3)
  • 0.2 mm (96)
  • 0.24 mm (1)
  • 0.25 mm (107)
  • 0.3 mm (97)
  • 0.32 mm (53)
  • 0.37 mm (5)
  • 0.38 mm (2)
  • 0.4 mm (46)
  • 0.4 mm (2-hole) (1)
  • 0.44 mm (1)
  • 0.45 mm (15)
  • 0.5 mm (71)
  • 0.5 mm (2-hole) (1)
  • 0.51 mm (2)
  • 0.53 mm (47)
  • 0.6 mm (3)
  • 0.64 mm (1)
  • 0.76 mm (5)
  • 0.8 mm (13)
  • 1 mm (13)
  • 1.0 mm (1)
  • 1.00 mm (1)
  • 1.02 mm (2)
  • 1.14 mm (4)
  • 1.2 mm (2)
  • 1.25 mm (1)
  • 1.30 mm (3)
  • 1.42 mm (1)
  • 1.52 mm (1)
  • 1.6 mm (4)
  • 1.65 mm (1)
  • 1.85 mm (2)
  • 1/16 in (46)
  • 1/16 to 1/32 in (1)
  • 1/4 in (14)
  • 1/4 to 1/16 in (1)
  • 1/4 to 1/4 in (2)
  • 1/4 to 1/8 in (4)
  • 1/8 in (24)
  • 1/8 to 1/16 in (4)
  • 1/8 to 1/4 in (1)
  • 10 mm (10)
  • 11 mm (44)
  • 13 mm (10)
  • 18 mm (1)
  • 2 mm (13)
  • 2.0 mm (17)
  • 2.06 mm (1)
  • 2.1 mm (73)
  • 2.4 mm (1)
  • 2.79 mm (1)
  • 20 mm (69)
  • 25 mm (7)
  • 3 mm (2)
  • 3.0 mm (43)
  • 3.18 mm (1)
  • 3.2 mm (7)
  • 4 mm (21)
  • 4.0 mm (13)
  • 4.6 mm (133)
  • 5 mm (1)
  • 5.0 mm (1)
  • 6 mm (2)
  • 7 mm (2)
  • 8 mm (12)
  • 9 mm (25)
Length
  • 0-10 (86)
  • 11-20 (174)
  • 21-30 (258)
  • 31-40 (11)
  • 41-50 (69)
  • 51-100 (256)
  • 101-200 (47)
  • 201-300 (46)
  • 301-400 (1)
  • 601-700 (7)
  • 701-800 (1)
  • 901-1000 (1)
Light Path
  • 1 mm (8)
  • 10 mm (25)
  • 10 x 10 mm (4)
  • 10 x 2 mm (3)
  • 10 x 4 mm (4)
  • 10 x 6.5 mm (1)
  • 100 mm (8)
  • 20 mm (14)
  • 4 x 4 mm (1)
  • 40 mm (1)
  • 5 mm (9)
  • 5 x 5 mm (2)
  • 50 mm (9)
Maximum Temperature (Celsius)
  • 20-30 (4)
  • 30-40 (33)
  • 40-50 (1)
  • Over 100 (15)
Minimum Temperature (Celsius)
  • 0-10 (7)
  • 10-20 (38)
  • 90-100 (2)
Model Compatible With
  • 3x00 XL/3x00 DV/3000 SCX/4300V/5300V/7300V (1)
  • AAnalyst (110)
  • AAnalyst 100 (6)
  • AAnalyst 200 (6)
  • AAnalyst 300 (6)
  • AAnalyst 400 (6)
  • AAnalyst 700 (10)
  • AAnalyst 800 (8)
  • APS-1650 (1)
  • ASX-1400 (1)
  • ASX-1600 (1)
  • ASX-260 (1)
  • ASX-520 (1)
  • ASX-520HS (1)
  • ASXPRESS PLUS (2)
  • Avio (186)
  • Avio 200 (45)
  • Avio 500 (50)
  • Clarus GCMS (1)
  • Diamond DMA (2)
  • Diamond TMA (3)
  • Dispersive Instruments (2)
  • DMA 8000 (11)
  • ELAN (11)
  • ELAN 5000 (22)
  • ELAN 6000 (1)
  • ELAN 6x00 (30)
  • ELAN 9000 (28)
  • ELAN 9000 Controller Side (2)
  • ELAN DRC (8)
  • ELAN DRCs (21)
  • EXR-8 (1)
  • FAST (24)
  • Flexar SQ 300 MS (4)
  • Frontier (81)
  • Frontier MIR (1)
  • Frontier MIR/NIR (1)
  • Frontier NIR (2)
  • Frontier Optica (1)
  • FT-IR (3)
  • FT-IR Sampling Kit (2)
  • Inductively Coupled Plasma (12)
  • LabChip GXII Touch 24 (1)
  • LabChip GXII Touch HT (1)
  • LC-290 (1)
  • LC-295 (1)
  • LC-90 (1)
  • Model 1100(B) (3)
  • Model 1600 (1)
  • Model 2100 (3)
  • Model 3100 (2)
  • Model 3110 (2)
  • Model 3300 (2)
  • Model 4100 (3)
  • Model 5000 (2)
  • Model 5100 PC (2)
  • NexION (15)
  • NexION 1000 (39)
  • NexION 2000 (46)
  • NexION 300 (53)
  • NexION 350 (54)
  • OilExpress (1)
  • Operetta (29)
  • Operetta CLS (8)
  • Operetta CLS AND Opera Phenix (9)
  • Optima (9)
  • Optima 2000/4000/5000 (1)
  • Optima 2x00 (2)
  • Optima 2x00 DV (35)
  • Optima 2x00/4x00/5x00/7x00 DV (10)
  • Optima 3000 SCX (5)
  • Optima 3000 XL (1)
  • Optima 3x00 DV (15)
  • Optima 3x00 RL (9)
  • Optima 3x00 Series Radial/Plasma 400/Plasma 40 (3)
  • Optima 3x00 XL (5)
  • Optima 4300 V (18)
  • Optima 4x00 (7)
  • Optima 4x00 DV (35)
  • Optima 5300 V (18)
  • Optima 5x00 (7)
  • Optima 5x00 DV (35)
  • Optima 7300 V (13)
  • Optima 7300V (5)
  • Optima 7x00 (7)
  • Optima 7x00 DV (35)
  • Optima 8x00 (53)
  • Paragon 1000 (1)
  • Paragon 500 (1)
  • PinAAcle (110)
  • PinAAcle 500 (4)
  • PinAAcle 900 (1)
  • PinAAcle 900F (4)
  • PinAAcle 900H (4)
  • PinAAcle 900T (4)
  • PinAAcle 900Z (4)
  • Plasma 1000, Plasma 2000, Plasma II, Plasma 400, Plasma 40 ICP/6500(XR) (1)
  • Plasma II, Plasma 40, ICP 6500XR/5500B (1)
  • Quechers Dispersive SPE (19)
  • S10 Autosampler (1)
  • Sample Preparation Blocks (62)
  • SC-2 Autosamplers (1)
  • SC-4 Autosamplers (1)
  • Solid Phase Extraction (SPE) (244)
  • Spectrum 100 (56)
  • Spectrum 1000 (1)
  • Spectrum 100N (4)
  • Spectrum 400 (55)
  • Spectrum 65 (53)
  • Spectrum BX (1)
  • Spectrum One (59)
  • Spectrum One NTS (4)
  • Spectrum RX (1)
  • Spectrum RX/BX FT-IR (2)
  • Spectrum Two (45)
  • Spectrum Two N (1)
  • SQ 8 (1)
  • TGA (1)
  • Titan (2)
  • Titan Microwave System (55)
  • TMA 4000 (1)
  • XLR-8 (1)
Number of Elements
  • Multiple (197)
  • Single (466)
Number of Wells
  • 1536 (8)
  • 24 (5)
  • 384 (17)
  • 96 (43)
Oncology Cell Line
  • Brain (2)
  • Melanoma (1)
  • Prostate (3)
  • Ovarian (1)
  • Liver (1)
  • Pancreatic (1)
  • Breast (3)
  • Fibrosarcoma (1)
  • Lung (3)
  • Blood (1)
  • Colorectal (3)
Outer Diameter
  • 0.028 in (5)
  • 0.47 mm (12)
  • 0.5 mm (16)
  • 0.63 mm (15)
  • 0.72 mm (4)
  • 0.8 mm (1)
  • 1.5 in (67)
  • 11 mm (8)
  • 13 mm (4)
  • 2 in (115)
  • 2 mm (1)
  • 25 mm (7)
  • 3 mm (2)
  • 35 mm (1)
  • 4 mm (13)
  • 5 mm (1)
  • 6 mm (1)
  • 6.2 mm (25)
  • 6.3 mm (1)
  • 7 mm (1)
  • 8 mm (1)
Particle Size
  • 1.9 µm (5)
  • 2.7 µm (132)
  • 3.0 µm (16)
  • 5.0 µm (76)
  • 7.0 µm (22)
  • 10.0 µm (10)
  • 20.0 µm (2)
Phase
  • (6%-cyanopropylphenyl)-methylpolysiloxane (17)
  • (low bleed) (1)
  • 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane (22)
  • 100% dimethyl polysiloxane (3)
  • 100% Dimethyl Polysiloxane (58)
  • 5% diphenyl / 95% dimethyl polysiloxane (13)
  • 5% diphenyl / 95% dimethyl polysiloxane (3)
  • 5% Diphenyl and 95% Dimethyl Polysiloxane (3)
  • 5% Diphenyl/95% Dimethyl Polysiloxane (10)
  • 5% Phenyl/ 95% Dimethyl Polysiloxane (1)
  • 6% cyanopropylphenyl / 94% dimethylpolysiloxane (2)
  • Alumina (3)
  • Amino (5)
  • Anion (1)
  • Anion exchange (2)
  • Aq C18 (5)
  • AX-300 (2)
  • Betadextrin (1)
  • c18 (2)
  • C18 (72)
  • C4 (2)
  • c8 (2)
  • C8 (48)
  • C8 (1)
  • Cyano (4)
  • Cyanoprpylphenyl dimethyl polysiloxane (31)
  • Cycanopropylmethyl-phenylmethylpolysiloxane (13)
  • Cyclosil (1)
  • Dimethyl Polysiloxane (15)
  • Dimethyl Polysiloxane (1)
  • Diphenyl Dimethyl Polysiloxane (62)
  • HILIC (18)
  • IBD (10)
  • Organic Acids (4)
  • Peptide ES-C18 (18)
  • PFP (19)
  • Phenyl (2)
  • phenyl group in the polymer backbone (2)
  • Phenyl Hexyl (18)
  • Phenyl Methyl Polysiloxane (46)
  • Polyethylene Glycol (55)
  • Polymer (3)
  • RP-Amide (18)
  • Silica (6)
  • Trifluoropropylmethyl polysiloxane (34)
Product Group
  • Accessories (9)
  • Accessory (18)
  • Acetylene Filter (1)
  • Adapters (17)
  • Adapters and Replacement Parts (17)
  • Add-on Kit (35)
  • Add-On Kits (23)
  • Advanced Filter System (2)
  • Air Dryer (2)
  • Application Pack (20)
  • Autosampler Syringe (18)
  • Bakeout Disk (1)
  • Barcode Readers (1)
  • Baseplates (1)
  • Benchtop Crimper (3)
  • Bending Replacement Parts (2)
  • Book (4)
  • Bubble Flow Meter (2)
  • Burner Drain Assemblies (2)
  • Burner Heads (4)
  • Burner System Components (5)
  • Calibration (EA) (16)
  • Cap for Ultra-Micro TrayCell (4)
  • Cap/Septa (79)
  • Capillary Assemblies and Tubing (39)
  • Capillary Assemblies and Tubing, Other Replacement Parts (1)
  • Capillary Tubing (11)
  • Caps & Plugs (1)
  • Capsules and Replacement Parts (6)
  • Carier Lines (2)
  • Cartridges (6)
  • Cell Changers (13)
  • Cell Holders (9)
  • Cell Rack (1)
  • Chemical Library (4)
  • Circular Cell (12)
  • Circular Cell Window (1)
  • Clamp Assemblies and Replacement Parts (4)
  • Clarus SQ 8C (1)
  • Clean-up Kits (16)
  • Column Application Packs (14)
  • Column Selection Kits (7)
  • Columns (170)
  • Compression Cell (3)
  • Compressor Replacement Parts (5)
  • Connectors (4)
  • Consumables and Supplies (19)
  • Cooling System (7)
  • Cover Gasket (2)
  • Covers (4)
  • Crimpers (5)
  • Cups (6)
  • Cylinders (1)
  • Cylindrical Cell (5)
  • D-Swafer (2)
  • Decapper (6)
  • Desiccant Kits (4)
  • Desolvation Accessory (6)
  • Detector Kit (4)
  • Deuterium Lamp (10)
  • DigestionTubes (16)
  • DigiFILTERs (3)
  • Disposable Macro Cell (3)
  • Disposable Micro Cell (3)
  • Disposable Semi-Micro Cell (3)
  • Drain Lines (1)
  • Drying Attachment (2)
  • Dust Cover (1)
  • EDL Driver Assemblies and Components (3)
  • Electrodeless Discharge Lamp (EDL) (15)
  • End Caps (5)
  • ESI MP2 Two-Stop (77)
  • FEP-Replacement Tubing, with one long screw fitting (1)
  • FEP-Replacement Tubing, with one short screw fitting (1)
  • Ferrule (50)
  • Fibrer Library (1)
  • Filter Element (8)
  • Filter for Mercury Analyzer (1)
  • Filter Replacement Part (11)
  • Filters (10)
  • Fittings (7)
  • Flexar SQ 300 MS Accessories (2)
  • Flow Injection Furnace Supplies (3)
  • Flow Meter (5)
  • Flow-Through Cell (9)
  • Fluorescence Cell for Magnetic Stirrer (2)
  • Food Library (1)
  • Gas Cabinet (1)
  • Gas Cell (7)
  • Gas Line Assembly (2)
  • Gas Lines, Other Replacement Parts (1)
  • Gas Purifier (28)
  • Gas Station (1)
  • Gas Tight Syringe (15)
  • Gas/Liquid Separator and Replacement Parts (5)
  • GC (1)
  • GC Compressor (6)
  • GC Syringe (12)
  • GladiATR Replacement Parts (3)
  • Guard Holder and Accessories (8)
  • HATR Accessory (9)
  • Heatable Transmission Accessory (1)
  • Heating Accessories (1)
  • HGA Graphite Contact Cylinders (3)
  • HGA Graphite Tubes (5)
  • High Pressure Analytical Static Mixers (10)
  • High Throughput Valves (2)
  • Hollow Cathode Lamp (HCL) (164)
  • Hook (1)
  • Hose Assembly (3)
  • Humidity Sensor (4)
  • Hydrogen Generator (4)
  • Hydrogen Generator - Replacement Parts (6)
  • Hydrogen Generator - Ultra (4)
  • ICP-OES Compressor (9)
  • Imaging Accessories (4)
  • Imaging Accessory (1)
  • Inductively Coupled Plasma (ICP-OES) (1)
  • Infrared Lamp (3)
  • Injection Valve (8)
  • Injection Valve Rotor Seals (4)
  • Injectors (74)
  • Inorganic (321)
  • Inorganics Library (1)
  • Instrument (8)
  • Integrating Sphere (2)
  • IR Specular Reflectance Set (1)
  • KBr Press (14)
  • KBr Random Cuttings (1)
  • Kit (33)
  • Lamp Adapter (66)
  • LC Flow Cell Accessory (1)
  • Lip Forming Seals (5)
  • Macro Cell with Glass Lid (3)
  • Macro Cell with PTFE Lid (17)
  • Macro Cell with PTFE Stopper (17)
  • Maintenance Kit (1)
  • Mass Flow Controllers (2)
  • Mass Spectral Library (1)
  • Material Pockets (3)
  • Mercury Lamp (1)
  • Mesh Pockets (2)
  • Metal Spill Tray (1)
  • Metallo-Organic (172)
  • Micro Cell Cap - Green (1)
  • Micro Cell with PTFE Lid (1)
  • Micro Cell with PTFE Lid - Black Sides (2)
  • Micro Syringes (5)
  • Microscopy Sampling Accessory (1)
  • Mixer Cartridge (3)
  • Mixing Block (1)
  • Mixing/Separation Assembly (1)
  • Monofibers (2)
  • MPLC Holder and Accessories (17)
  • Nebulizers (93)
  • Needles (4)
  • NIR Accessory (3)
  • Nitrogen Generator (9)
  • Nut (18)
  • Nut and Ferrule Kit (6)
  • O-Rings (28)
  • oneFAST Systems (3)
  • Organic (46)
  • Other Replacement Parts (9)
  • Outer Liner (1)
  • Outer Tubes (2)
  • Pads (1)
  • Pan Crimper (16)
  • Pecosphere Holder (2)
  • Pestle and Mortars (1)
  • Petrolium Library (1)
  • Pin Vise (1)
  • Pipette Tips (1)
  • Plate (4)
  • Plug (5)
  • PMMA (1)
  • Polarization Accessory (2)
  • Polarizer (1)
  • Powder (1)
  • Power Conditioner (3)
  • Prep-10 Holder and Accessories (2)
  • Press-N-Lock Cell (2)
  • Pressure Gauge (1)
  • Probe Assembly (1)
  • Probes (26)
  • Probes and Holders (12)
  • Probes and Sample Tools (9)
  • Pump (4)
  • Racks (13)
  • Reagent (EA) (17)
  • Recessed Top Plate (1)
  • Rectangular Cell (37)
  • Rectangular Cell (1)
  • Rectangular Sealed Liquid Cell (18)
  • Reflectance Accessory (3)
  • Regulator (17)
  • Replacement Needle (16)
  • Replacement Part (75)
  • Replacement Parts (54)
  • Rotors and Stators (26)
  • Sample Holder (7)
  • Sample Holder Cover Reforming Tool (1)
  • Sample Introduction Kits (11)
  • Sample Load Fixture (1)
  • Sample Needle (2)
  • Sample Pans (45)
  • Sample Plates (1)
  • Sample Probe (1)
  • Sample Support (1)
  • Sample Tubes (3)
  • Sampling Needle (1)
  • Sampling Supplies (3)
  • Sampling System (3)
  • Scoop (1)
  • Screw Caps (7)
  • Screw Driver (1)
  • Scribes (1)
  • Sealed Liquid Cell (3)
  • Seals (2)
  • Semi-Micro Cell with PTFE Lid (2)
  • Semi-Micro Cell with PTFE Lid - Black Sides (5)
  • Semi-Micro Cell with PTFE Lid - Clear Sides (3)
  • Semi-Micro Cell with PTFE Stopper (2)
  • Semi-Micro Cell with PTFE Stopper - Black Sides (2)
  • Semi-Micro Cell with PTFE Stopper - Clear Sides (2)
  • Septa (1)
  • Shoe (2)
  • Silanized Glass Wool (1)
  • Sipper Tubing to Cuvette (in) (1)
  • Skimmer (6)
  • Software and Informatics (2)
  • Spares Kits (6)
  • SPB Fume Hoods (4)
  • SPB Replacement Parts (3)
  • Sponges and Cloths (2)
  • Spray Chambers (12)
  • Standard Tungsten Filament (1)
  • Start Up Kits (8)
  • Starter Kit (46)
  • Starter Kits (3)
  • Stators (1)
  • Sticks (3)
  • Stirrers and Replacement Parts (1)
  • Stopcocks (2)
  • Surface Accessory (1)
  • Swafer Kit (2)
  • Syringe (5)
  • Syringe Filters (34)
  • Tee (4)
  • Temperature Controlled Spray Chambers (23)
  • Temperature-Controlled Cell for Fluorimetry (1)
  • Thermostatting Accessory (8)
  • THGA Graphite Contact Cylinders (2)
  • THGA Graphite Tubes (5)
  • Three-Stop (9)
  • Titan Accessories (3)
  • Titan Replacement Parts (10)
  • Tool Kit (2)
  • Top Plate Accessory (3)
  • Top Plates (28)
  • Torch Replacement Parts (2)
  • Torches (10)
  • Trap (1)
  • Trays and Racks (50)
  • Tubes & Vials (6)
  • Tubing (6)
  • Tubing and Replacement Parts (3)
  • Tungsten Lamp (6)
  • Turntables (7)
  • Two-Stop (43)
  • UATR Accessory (4)
  • UATR Polarization Accessory (2)
  • Ultra Clean Filter (23)
  • Ultra-Micro Cell with Pipette Tips (4)
  • Ultra-Micro Cell with PTFE Lid (1)
  • Ultra-Micro Cell with PTFE Stopper (1)
  • Ultramicro Syringe (5)
  • Union (38)
  • Universal Reflectance Accessory (2)
  • Upgrade Kit (4)
  • UV Cuvette (2)
  • UV Lamps (1)
  • Vacuum Manifolds (2)
  • Vacuum Pump (1)
  • Vacuum Pumps (3)
  • Valve Replacement Parts (4)
  • Valves (7)
  • Variable Angle Accessory (2)
  • Variable Temperature Cell (5)
  • Variable-Angle Accessory (1)
  • Venturi Tubes (2)
  • Vessels and Spares (23)
  • Vial (31)
  • Vial Insert (15)
  • Vial Rack (2)
  • Watch Glasses (4)
  • Weighing Cups (2)
  • Well plates (33)
  • Wrench (4)
  • Zero Air Generator (13)
Standard Type
  • AA Standards (8)
  • Acid Number (12)
  • Analytes (1)
  • Aqueous (1)
  • ASTM D-6584 (1)
  • Base Number (13)
  • Biodiesel (4)
  • Calibration (15)
  • Calibration Mix (HPLC) (1)
  • Cloth (EA) (1)
  • Contract Lab Program Modification Set (9)
  • Contract Required Detection Limits (1)
  • Environmental (2)
  • Environmental (5)
  • Fuel Dilution (2)
  • Glycerol (1)
  • Initial Calibration Verification (1)
  • Initial Calibration Verification (1)
  • Initial Calibration Veri�tion (1)
  • Installation (1)
  • Instrument Calibration (48)
  • Interference Check (3)
  • Interference Solutions (6)
  • Internal (3)
  • Internal (5)
  • Ketones for Method 8260B (1)
  • Low UV Standard (1)
  • Matrix Oils and Solvents (6)
  • Metal Additive (1)
  • Metal Additive (3)
  • Method 505 (1)
  • Method 524.2 (3)
  • Method 525.2 (2)
  • Method 608 (1)
  • Method 624 Standards (5)
  • Method 625 (5)
  • Method 8082 PCB's Standards Kit (1)
  • Method 8260B Standards (2)
  • Method 8270C Mixes (3)
  • Method 8270C Standards (2)
  • Method 8270C Surrogates (2)
  • Mix B Purgeable Gases for Methods 8260B/524.2 (1)
  • Mixed Calibration (6)
  • Multi-Element (11)
  • Nitric Acid Blanks (2)
  • Pesticides (3)
  • Quality Control (3)
  • Reagents (17)
  • Reference Materials (1)
  • Single-Element (228)
  • Spike (2)
  • Sulfur (17)
  • Test Mix (4)
  • Test Samples (1)
  • Universal Data Acquisition (1)
  • USP/ICH Standards (4)
  • V-21 + K Wear Metal (18)
  • V-21 Wear Metal (21)
  • V-23 Wear Metal (21)
  • Viscosity Reference (9)
  • Volatile Organics Combination Blend (1)
  • Water Blank (2)
  • Water Pollutant (7)
Style
  • Advanced Platform (4)
  • Advanced Platform, End-Capped (1)
  • Crimp Top (73)
  • End-Capped, Integrated Platform (1)
  • Flared (35)
  • Forked (1)
  • Integrated Platform (4)
  • L'vov Groove (2)
  • Partitioned (1)
  • Screw Top (56)
  • Snap Top (18)
  • Standard (106)
  • Wall (1)
Technology
  • Anion Exchange (1)
  • Atomic Absorption (5)
  • Capillary (187)
  • Capillary - General Purpose (202)
  • Capillary - Specialty Application (74)
  • Capillary Guard Column (2)
  • Cartridge (111)
  • Cartridge Column (55)
  • Conventional (112)
  • Conventional Column (38)
  • Conventional-Guard (9)
  • Custom Packed Columns (24)
  • Elemental Analysis (1)
  • Gas Chromatography (4)
  • Gas Chromatography/Mass Spectrometry (5)
  • Guard column (7)
  • ICP Mass Spectrometry (1)
  • ICP Optical Emission Spectroscopy (1)
  • Infrared (IR) (20)
  • IR (2)
  • Mercury Analysis Systems (2)
  • Reverse Phase (32)
  • Thermal Analysis (9)
  • UV/Visible (18)
Technology Type
  • AA (29)
  • Atomic Absorption (1)
  • Atomic Absorption (AA) (249)
  • Atomic Spectroscopy (2)
  • ATR (69)
  • ATR FT-IR (1)
  • Autosampler (97)
  • Buffer Tubing (5)
  • Capillary Split/Splitless (18)
  • CHNO (2)
  • Chromatography (15)
  • Diffuse Reflectance (13)
  • Disposable (2)
  • DSC (13)
  • EA (42)
  • Elemental Analysis (1)
  • Fiber Optics (9)
  • Flow Injection Tubing (18)
  • Fluorescence (FLR) (1)
  • Fluorescence Sampling (4)
  • FT-IR (20)
  • FT-IR Spectroscopy (16)
  • Headspace (67)
  • ICP Mass Spectrometry (2)
  • ICP Optical Emission Spectroscopy (1)
  • ICP-MS (58)
  • ICP-MS & ICP-OES (1)
  • ICP-MS, ICP-OES (10)
  • ICP-OES (87)
  • Infrared Spectroscopy (FT-IR) (1)
  • Integrating Spheres (4)
  • Liquid Chromatography (LC) (9)
  • Mass Spectrometry (1)
  • MHS (1)
  • Multivendor (32)
  • NIR Spectroscopy (1)
  • O-ring (1)
  • Packed Clear (12)
  • Packed Colored (6)
  • Packing material (1)
  • Peristaltic Pump Tubing (131)
  • Programmed Temperature Split/Splitless (PSS) (9)
  • Pump Tubing (8)
  • Rechargeable (4)
  • Specular Reflectance (12)
  • TGA (1)
  • Thermal Analysis (9)
  • Tubing Kits and Spares (FLR) (4)
  • Tubing Kits and Spares (GC) (2)
  • Tubing Kits and Spares (IR) (5)
  • Tubing Kits and Spares (LC) (5)
  • Tubing Kits and Spares (UV) (2)
  • Tubing Spares (1)
  • UV/VIS (1)
  • UV/Visible (UVS) (12)
Thickness
  • 0.025 (2)
  • 0.05 (2)
  • 0.1 (2)
  • 0.2 (2)
  • 0.5 (2)
  • 1.0 (1)
  • 2.0 (5)
  • 4.0 (11)
Type
  • 0-Slot (2)
  • 1-Slot (2)
  • Air Monitoring (1)
  • Air-Acetylene (4)
  • Baffled & Cyclonic (3)
  • Biocompatible Titanium (6)
  • Compressed Air (1)
  • Consumables (10)
  • Cyclonic (4)
  • Edwards E2M28 (1)
  • End-Capped (2)
  • Fixed (24)
  • Flared (1)
  • Hydrocarbon (4)
  • ICP-MS (1)
  • LC (1)
  • Liquid,Solid (1)
  • Micropump Stainless Steel (6)
  • Moisture (5)
  • Moisture,Hydrocarbon (4)
  • Moisture,Oil,Dust (1)
  • None (6)
  • Oil,Water,Particulate (1)
  • Opal 520 (1)
  • Opal 540 (1)
  • Opal 570 (1)
  • Opal 620 (1)
  • Opal 650 (1)
  • Opal 690 (1)
  • Oxygen (3)
  • Oxygen,Moisture (3)
  • Oxygen,Moisture,Hydrocarbon (16)
  • Peristaltic (2)
  • Peristaltic Pump (2)
  • Removable (29)
  • Scott (2)
  • Series 200 (2)
  • Series 200 (5)
  • Series 200, Series 250, Series 410 (1)
  • Standard (15)
  • Standard Stainless Steel (3)
  • Standard Stainless Steel, Biocompatible Titanium (3)
  • Standard Stainless Steel, Micropump Stainless Steeel, Biocompatible Titanium (1)
  • Standard Stainless Steel, Micropump Stainless Steel (2)
  • UltraClean (1)
  • Water,Oil,Dirt (1)
Volume
  • 0-50 (102)
  • 51-100 (1)
  • 201-250 (72)

1-12 of 8074 Products & Services

Sort by

  • QSight 210 MD Instrument Front

    QSight® 210 MD Screening System

    The complete solution for high throughput routine quantification.
  • QSight Triple Quad LC-MS

    QSight Triple Quad LC/MS/MS

    Ideal for analyzing food, cannabis, and environmental samples, our robust and reliable QSight® triple quad systems consistently deliver the throughput and productivity you need in your analytical testing lab. Now we’ve added the premier model to our QSight family: the high performance 400 series. This ready-to-implement solution has the highest sensitivity and throughput the industry has ever seen and the capability to test for the most challenging, complex samples, including cannabis.
  • UNIFILTER-96 CELL HARVESTER

    Speed and simplicity are the primary strengths of the Unifilter Harvester.
  • UNIFILTER-96 CELL HARVESTER SS

    Speed and simplicity are the primary strengths of the Unifilter Harvester.
  • JANUS G3 Btx Pro-Plus

    JANUS G3 BioTx Pro Plus Workstation

    The JANUS® G3 Bio Tx Pro Plus offers full walk-away automation for high-throughput process development, enabling more data from precious starting materials and limited resources.
  • Spotlight 200i FT-IR Microscopy Systems

    Spotlight 200i FT-IR Microscopy Systems

    Spotlight IR microscope systems are designed to meet the challenges of an expanding laboratory by generating high-quality, reproducible data from a variety of sample types. The Spotlight encompasses intelligent technology and simplicity in operation to take on today’s challenges and those to come.
  • Avio 500 ICP OES

    Avio 500 ICP Optical Emission Spectrometer

    PerkinElmer’s new Avio® 500 is a truly simultaneous, dual view, and compact ICP-OES. It utilizes a vertical plasma and is engineered to handle even the most difficult, high-matrix samples without dilution, delivering productivity, performance, and faster return on investment.
  • LAMBDA XLS with SD Memory Card

    LAMBDA XLS+ with SD Memory Card

    For over 50 years we have remained at the forefront of research and innovation. Now, we have drawn on our experience to bring you the LAMBDA XLS+ spectrophotometer, the instrument you can depend on to meet the demands of your busy laboratory.
  • Avio-200-ICP-OES-Elevated-Front-320x320

    Avio 200 ICP Optical Emission Spectrometer

    The Avio 200 is a compact ICP-OES that combines a vertical plasma design with a host of unique hardware features to handle even the most difficult, high-matrix samples without dilution, delivering a whole new level of performance and flexibility to ICP.
  • 1000x1000_Opera_Phenix

    Opera Phenix High-Content Screening System

    The Opera Phenix High Content Screening System is the premier confocal solution for today's most demanding high content applications. Drawing on over a decade of experience with the industry-leading Opera® High Content Screening System, the Opera Phenix is designed for high-throughput, phenotypic screening and assays involving complex disease models, such as live cells, primary cells and microtissues.
  • TRI-CARB 4810TR 110 V Liquid Scintillation Counter

    The Tri-Carb 4810TR liquid scintillation counter is ready to go for basic research and CPM/direct DPM applications. With the Tri-Carb 4810TR, you get many of the performance advantages of a more-fully featured Tri-Carb system.
  • PinAAcle 900 Series Atomic Absorption Spectrometer

    PinAAcle 900F Atomic Absorption Spectrometer

    For laboratories needing a high-performance flame atomic absorption (AA) spectrometer, the PinAAcle 900F is a flame-only system with a true double-beam design for fast start-up and exceptional long-term stability.
  • Jump to: