PerkinElmer

hyphenated-technology

Business Insights (22)
Filters:

Filters :

Resource Library
  • Application Note (17)
  • Article (1)
  • Brochure (1)
  • Case Study (1)
  • Product Note (1)
  • Technical Note (1)

1-12 of 22 Business Insights

Sort by

  • Brochure

    The Power of the Sun, Solar Energy Development Solutions

    As the demand for solar power continues to grow, there needs to be a clear focus on different key issues in the life cycle of a solar cell. These issues are: efficiency, durability and cost. Coupling PerkinElmer’s application knowledge and experience together with our product portfolio, we can help manufacturers overcome these obstacles. At PerkinElmer, we’re taking action to ensure the quality of our environment.

  • Product Note

    Rapid, Cost-Effective Oil Condition Monitoring -- Spectrum OilExpress System

    Designed specifically to meet the requirements of the Caterpillar® S.O.SSM program, the JOAP program, and the new ASTM® Methods D7412, D7414, D7415, D7418, Spectrum™ OilExpress is the fastest, most cost-effective Oil Condition Monitoring (OCM) solution for busy test laboratories. OilExpress also uses less than half the solvent required by competing systems, dramatically reducing day-to-day operating costs and making laboratories more competitive.

  • Application Note

    Curing Determination of EVA for Solar Panel Application

    This study shows that DSC can be used to study the curing degree of the EVA resin by measuring the residual curing enthalpy. The data show that the residual curing enthalpy can be correlated to the curing time in a linear way. The DSC test is quick and easy.

  • Application Note

    Cavity-enhanced Absorption Spectroscopy for Trace Gas Detection with Frontier

    Cavity-enhanced absorption spectroscopy (CEAS) has similarities with the better known cavity ringdown technique (CRDS) which measures the signal decay as a laser pulse emerges through one of the mirrors after successive reflections. By measuring the increase in the rate of decay caused by an absorbing species, CRDS can measure ppb concentrations of small molecules. The ringdown technique has typically been applied to small molecules where the wavelength of a NIR laser source can be tuned across very narrow individual lines of the spectra. In contrast this report describes CEAS using a broadband source applied to larger molecules where the spectra are broader.

  • Application Note

    Biodiesel Concentration Measurements Using Attenuated Total Reflectance (ATR)

    Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are several characteristics that are of concern. These differences, especially the cetane reduction, require that adequate control of the biofuel concentration be implemented.

  • Application Note

    High Resolution Characterization of Pharmaceutical Polymorphs Using Power Compensation DSC

    Many pharmaceutical materials exhibit polymorphism, which means that, depending upon the given processing conditions, the crystalline form may exist in two or more states. The crystalline states or forms exhibit different levels of thermodynamic stabilities and an unstable form can melt at a temperature significantly less than the melting point of the thermodynamically stable form. Depending upon the conditions used to generate the crystalline form(s), the drug may exhibit one or more unstable, polymorphic crystalline states.

  • Application Note

    Diamond ATR and Calibration Transfer for Biodiesel-Blend Analysis by ASTM D7371

    Biodiesel is seldom used neat (B100), typically being blended with fossil diesel at ratios from 5% v/v (B5) to 30% v/v (B30). Verifying the FAME content of diesel-fuel blends is an important aspect of quality control and auditing of blending and distribution operations. Because FAME has a strong infrared absorption at 1745 cm-1 due to the ester carbonyl group, infrared spectroscopy is an excellent technique for this analysis, and there are EN and ASTM® standard test methods describing the procedure

  • Application Note

    Determination of Oil Content in Membranes Used in Compressed Air Sampling by Infrared Spectroscopy

    This note describes the test method for the quantitative analysis of aerosol oil and liquid oil typically present in the air discharged from compressors and compressed air systems. The method is rapid, sensitive and cost effective and shows the FT-IR can be an effective tool for the monitoring of oil content. The methodology followed for the analysis by FT-IR is reported in Bureau of Indian Standard and we have also tested for its ruggedness, spike recovery, linearity and detection limits.

  • Application Note

    Determining the Source Oil of Biodiesel with Infrared Spectroscopy

    Infrared spectroscopy is particularly suitable for the identification of materials, even when the differences between the materials are subtle variations in complex mixtures. In this note we demonstrate that biodiesel from several common feedstocks can be distinguished on the basis of absorption bands arising from double bonds in the fatty acid chains.

  • Application Note

    HyperDSC for High Throughput Formulation Development

    The concept of High-Throughput Design has gained more and more interest as a way to increase profitability and to decrease research costs. One technique that can increase the ability of a laboratory to evaluate formulations is HyperDSC™ or High Ramping Rate DSC. HyperDSC is the ability to quantitatively measure small samples at extreme heating and cooling rates, typically 100-500 °C/min.

  • Application Note

    Study Rigid Amorphous Fraction in Polymer Nano-Composites by StepScan and HyperDSC

    Heat capacity measurement has been performed in order to detect a possible second Tg on nanocomposites of polymethyl methacrylate (PMMA) with silicon oxide nanoparticles of different shape. StepScan™ DSC was used for determination of precise heat capacity and HyperDSC® to prevent degradation and identify devitrification of the RAF at elevated temperatures.

  • Application Note

    A novel method (TG-IR) for the rapid determination of Total Petroleum Hydrocarbons (TPH) in soil

    A gas chromatographic analysis of the extract can provide even greater sensitivity and more detailed compositional information, but further increases the time required for the analysis. Thermogravimetric analysis coupled to infrared spectroscopy (TG-IR) can provide detailed information about the amount and nature of the pollution, while requiring no sample preparation at all. This application note illustrates the kind of data that can be obtained with a modern TG-IR system.

  • Jump to:
Products & Services (10)
Filters:

1-10 of 10 Products & Services

Sort by

  • Frontier MIR/NIR + SP10 STD

    Frontier MIR Spectrometer

    Choose the Frontier range of Fourier Transform IR spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. An exceptional signal-to-noise ratio and photometric performance assures optimal spectral quality to ensure best-in-class sensitivity. This configurable platform provides dependable and consistent operation through years of service.

  • Simultaneous Thermal Analyzer (STA) 6000

    The STA 6000 simultaneous thermal analyzer offers performance, reliability and productivity you can depend on.
  • Frontier MIR/NIR + SP10 STD

    Frontier MIR/NIR Spectrometer

    Choose the Frontier range of Fourier Transform IR spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. An exceptional signal-to-noise ratio and photometric performance assures optimal spectral quality to ensure best-in-class sensitivity. This configurable platform provides dependable and consistent operation through years of service.

  • LAB SYS-DSC 8500

    The DSC 8500 is a double-furnace DSC, featuring our second-generation HyperDSC technology. Now you can gain unlimited insight into the structure, properties and performance of your materials.
  • Spectrum Two FT-IR Spectrometer

    Spectrum Two FT-IR Spectrometer

    Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications.
  • TGA 4000 N5370210

    TGA 4000 System, 100-240V/50-60Hz

    The TGA 4000 is designed with a compact ceramic furnace, which provides the temperature control you need for accurate results. Its rugged design is also corrosion resistant for the applications flexibility you need today and tomorrow.
  • DSC 4000 System, 100-240V/50-60Hz

    The DSC 4000 offers dependable performance and quality results. This single-furnace, heat flux DSC is designed to run all your routine applications and includes an easy-to-load vertical furnace that is resistant to oxygen and chemical corrosion.
  • DSC6000

    DSC 6000

    The DSC 6000 gives you all the advantages of the DSC 4000 and more. Designed for research application, it comes with Modulated Temperature DSC (MT-DSC) technology for easier data interpretation and new capabilities for product development.
  • DSC 8000

    The DSC 8000, double-furnace, power compensation DSC provides greater sensitivity and accuracy as well as faster and more reliable results then you ever thought possible.
  • Simultaneous Thermal Analyzer (STA) 8000

    Simultaneous Thermal Analyzer (STA) 8000

    The STA 8000 simultaneous thermal analyzer offers performance, reliability and productivity you can depend on.