Spectrum Two In-Service Lubricants FT-IR Analysis System | PerkinElmer
PerkinElmer
check quantity

Spectrum Two In-Service Lubricant Analysis System

Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications. Choose the Spectrum Two + that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity.

Part Number
Model Name
L160000A
Spectrum Two FT-IR Spectrometer (LiTaO3 Detector)
more
L160000F
Spectrum Two FT-IR Spectrometer (DTGS Detector)
more
L1390021
Spectrum Two N FT-NIR Spectrometer (LiTaO3 Detector)
more
L1390023
Spectrum Two N FT-NIR Spectrometer (InGaAs Detector)
more
L160000T
Spectrum Two Pharmaceutical System
more
L160000W
Spectrum Two Nutraceutical & TCM System
more
L160000Q
Spectrum Two In-Service Lubricant Analysis System
more
L160000S
Spectrum Two Environmental Hydrocarbon Analysis System
more
L160000U
Spectrum Two Educational System
more
L160000R
Spectrum Two IR Biodiesel Analysis System
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Complete Solutions for Your Lab

The Spectrum Two offers trouble-free analysis of in-service lubricants. Intuitive design features and dedicated in-service lubricants analysis protocols enable even inexperienced IR users to generate clear, high quality results.

This out-of-the box solution enables labs to get up and running faster, regardless of the level of expertise. This comprehensive compilation of materials includes detailed SOP’s, sampling accessories, calibrations, and quick reference guides, all brought together through the Touch App interface. This system includes:

  • In-Service Lubricants Application Pack
  • Spectrum Two Instrument
  • Spectrum 10 Software

FT-IR In-Service Lubricants Application Pack

The FT-IR In-Service Lubricants Application Pack contains all of the resources and components necessary to perform efficient lubricant analysis in the laboratory and out in the field.

The In-Service Lubricants Application Pack contains:

  • Flow cell with ZnSe windows, a wedged spacer, and Leur fittings
  • 3 mL Leur Lok plastic syringe starter pack of 100
  • Torque screwdriver
  • HEX BIT, 3.0 mm
  • IR Liquid Cell Leur Connected Waste Tube
  • PTFE plugs (pack of 6)
  • In-Service Lubricants Touch Apps Software Kit

The Touch Apps Software Kit includes the software and SOPs to support the condition monitoring of in-service lubricants and provide a simplified workflow-driven operating environment; for faster, more reproducible analyses.

The Touch Apps software supports the following analyses:

  • JOAP direct-trending methods for petroleum, synthetic lubricants, and hydraulic fluids.
  • ASTM E2412 direct-trending and spectral-subtraction methods.
  • PerkinElmer methods for mineral and synthetic oils, petroleum hydraulic fluids, and turbine fluids. The SOPs provide clear instructions for day-to-day use and validation of the system; while the User’s Guide contains detailed instructions for oil condition monitoring, as well as instructions for the maintenance of the system and customization of the Spectrum Touch applications.

Spectrum Two Instrument

The Spectrum Two spectrometer with KBr optics and a standard, high-performance room temperature LiTaO3 (lithium tantalate) detector delivers a spectral scan range of 8,300 – 350 cm-1 whilst offering 0.5 cm-1 resolution and 9,300:1 peak-peak signal-to-noise ratio for a 5 second scan in a sleek, compact design.

Key features that allow for consistent performance of this system include:

  • Dynascan interferometer – Fixed mirror-pair interferometer design does not require dynamic alignment to compensate for errors.
  • OpticsGuard technology – Unique humidity shield design protects Spectrum Two from environmental effects, allowing it to be used in more challenging conditions. Our long-life desiccant ensures maximum instrument uptime, regardless of where your analysis takes place.
  • Atmospheric Vapor Compensation (AVC) – Features an advanced digital filtering algorithm designed to compensate for CO2 and H2O absorptions in real time removing the need for instrument purging.
  • Automatic Performance Verification (APV) – Optional feature comprising an integrated, fully automatic filter wheel containing traceable reference materials and software allowing for abscissa, ordinate, noise, ASTM, and USP tests to be performed.
  • Absolute Virtual Instrument (AVI) – Optional AVI standardization using gas phase methane spectra ensures instruments are accurately calibrated. Unique standardization allows data to be transferred precisely between instruments, side-by-side or in remote locations.
  • Sigma-Delta Conversion: The use of Sigma-Delta converters in the digitization of the FT-IR interferogram improves the dynamic range, reduces spectral artifacts, and increases ordinate linearity to provide accurate, reproducible results.

Spectrum 10 Software

Included in this system is the Spectrum 10 software, which enables you to control the instrument and to manipulate the spectra that you collect. The spectrometers can operate in ratio, single-beam, or interferogram mode.

 

From material and contaminant identification to quantitative analysis, the comprehensive Spectrum 10 software suite allows you to focus on what matters most – results. Designed for busy academic laboratories, this comprehensive FT-IR software package facilitates data collection, processing, results generation, basic and advanced data manipulation, spectral calculations, COMPARE spectral comparison, PLS/PCR/Beer’s Law predictions, Beer’s Law Quant method development, spectral search with starter libraries, and built-in online tutorials. The software enables users without scientific training to generate infrared spectra from a sample and validate them against reference spectra in minutes, or even seconds.

Specifications

Depth 30.0 cm
Detector Type LiTaO3
Height 21.0 cm
Model Name Spectrum Two In-Service Lubricant Analysis System
Operating Range 5 - 45 °C
Portable Yes
Product Brand Name Spectrum Two
Product Group Application Pack
Warranty 1 year
Wave Length Range 8,300 – 350 cm-1
Weight 13.0 kg
Width 45.0 cm
Resources, Events & More
  • All

Infographic

Product Note

Spectrum Two In-Service Lubricants Analysis System

Lubricant failure due to oxidation and nitration can be detrimental to machinery’s performance, while contamination by water, fuel or glycol can provide an early warning of mechanical problems before catastrophic damage occurs. Spectrum Two™ from PerkinElmer offers trouble-free analysis of in-servic ...

PDF 258 KB