Spectrum Two FT-IR Spectrometer with DTGS Detector | PerkinElmer
PerkinElmer
check quantity

Spectrum Two FT-IR Spectrometer

Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications. Choose the Spectrum Two + that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity.

Part Number
Model Name
L160000A
Spectrum Two FT-IR Spectrometer (LiTaO3 Detector)
more
L160000F
Spectrum Two FT-IR Spectrometer (DTGS Detector)
more
L1390021
Spectrum Two N FT-NIR Spectrometer (LiTaO3 Detector)
more
L1390023
Spectrum Two N FT-NIR Spectrometer (InGaAs Detector)
more
L160000T
Spectrum Two Pharmaceutical System
more
L160000W
Spectrum Two Nutraceutical & TCM System
more
L160000Q
Spectrum Two In-Service Lubricant Analysis System
more
L160000S
Spectrum Two Environmental Hydrocarbon Analysis System
more
L160000U
Spectrum Two Educational System
more
L160000R
Spectrum Two IR Biodiesel Analysis System
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

IR for Everyone, Everywhere

Spectrum Two breaks ground in operational simplicity, combining superb performance with low maintenance design. True laboratory performance IR for everyday analysis is possible for everyone, everywhere.

The Spectrum Two is suitable for a wide range of applications and can be configured to your needs regarding the level of performance desired to meet the demands of your daily IR analyses. See the configurations table below for all available instrument options.

Spectrum Two FT-IR spectrometers feature:

  • Standard, high-performance, room-temperature LiTaO3 (lithium tantalate) MIR detector with a SNR of 9,300:1
  • Optional temperature-stabilized, high-performance DTGS (deuterated triglycine sulfate) MIR detector with a SNR of 14,500:1. Ideal for low-light, high throughput applications
  • Standard optical system with KBr windows for data collection over a spectral range of 8,300 – 350 cm-1 at a best resolution of 0.5 cm-1
  • Optional ZnSe windows, for use in exceptionally humid environments for data collection over a spectral range of 6,000-550 cm-1
  • Standard AVC with optional APV/AVI configuration

Additional features that allow for consistent performance of this system include:

  • Dynascan interferometer – Fixed mirror-pair interferometer design does not require dynamic alignment to compensate for errors.
  • OpticsGuard technology – Unique humidity shield design protects Spectrum Two from environmental effects, allowing it to be used in more challenging conditions. Our long-life desiccant ensures maximum instrument uptime, regardless of where your analysis takes place.
  • Atmospheric Vapor Compensation (AVC) – Features an advanced digital filtering algorithm designed to compensate for CO2 and H2O absorptions in real time removing the need for instrument purging.
  • Automatic Performance Verification (APV) – Optional feature comprising an integrated, fully automatic filter wheel containing traceable reference materials and software allowing for abscissa, ordinate, noise, ASTM, and USP tests to be performed.
  • Absolute Virtual Instrument (AVI) – Optional AVI standardization using gas phase methane spectra ensures instruments are accurately calibrated. Unique standardization allows data to be transferred precisely between instruments, side-by-side or in remote locations.
  • Sigma-Delta Conversion – The use of Sigma-Delta converters in the digitization of the FT-IR interferogram improves the dynamic range, reduces spectral artifacts, and increases ordinate linearity to provide accurate, reproducible results.

For Every Application

PerkinElmer recognizes that every application is different. The result is a complete solution to provide the fastest assurance of the quality of your materials, regardless of the application. Some of the industry applications that the Spectrum Two is designed to accommodate include:

  • Pharmaceuticals and Nutraceuticals
  • In-service lubricants and fuels
  • Environmental
  • Polymers
  • Academia

For these specific applications, we offer various analysis systems and application pack add-ons. Spectrum Two is designed to function with a variety of “plug-and-go” sampling accessories to enhance the versatility of the instrument. We offer a range of UATR, HATR, Diffuse Reflectance, and Specular Reflectance accessories for use with the Spectrum Two system.

Results Matter

The Spectrum 10 software supplied with your instrument enables you to control the instrument and to manipulate the spectra that you collect. The spectrometers can operate in ratio, single-beam, or interferogram mode.

From material and contaminant identification to quantitative analysis, the comprehensive Spectrum 10 software suite allows you to focus on what matters most – results. Designed for busy industrial or academic laboratories, this comprehensive FT-IR software package facilitates data collection, processing, and results generation. The software enables users without scientific training to generate infrared spectra from a sample and validate them against reference spectra in minutes, or even seconds. For regulated industries that demand secure IR quality testing, Spectrum 10 ES software is available. Spectrum 10 ES includes the comprehensive features of Spectrum 10 and encompasses user access control, audit trailing, data security, and data integrity to ensure secure analyses to meet the technical demands of 21 CFR Part 11 compliance.

Collaborate From The Cloud

Spectrum 10 software with NetPlus cloud connectivity offers new sharing and collaborative tools that allow you to access data from any device, any time, from anywhere, and selectively distribute and download data and methods through the built-in publishing tool.

  • Securely share data, calibrations, methods, and reports
  • Collaborate by accessing IR data from any device, whenever and wherever it’s needed

IR Ready to Go

The compact and robust design of the Spectrum Two means that the instrument can be easily transferred between environments. The simple user-installation and fast warm-up time means that the instrument can be set up quickly. The wide range of sampling accessories available can help your analysis move out of the laboratory. With optional features such as wireless connectivity to enable portable PC control, or the Portability Pack featuring a carrying case, battery pack, and 12V car auxiliary port adaptor, the Spectrum Two is ready to go where you go.

Specifications

21 CFR Part 11 Compatible Yes
Depth 30.0 cm
Detector Type DTGS
Height 21.0 cm
Model Name Spectrum Two FT-IR Spectrometer (DTGS Detector)
Operating Range 5 - 45 °C
Portable Yes
Product Brand Name Spectrum Two
Warranty 1 year
Wave Length 8300 - 350 cm-1
Weight 13.0 kg
Width 45.0 cm

Configurations

Detector Type Windows APV/AVI? Software Part Number
DTGS KBr No Spectrum 10 L160000E
DTGS KBr No Spectrum 10 ES L160000M
DTGS KBr Yes Spectrum 10 L160000F
DTGS KBr Yes Spectrum 10 ES L160000N
DTGS ZnSe No Spectrum 10 L160000G
DTGS ZnSe No Spectrum 10 ES L160000O
DTGS ZnSe Yes Spectrum 10 L160000H
DTGS ZnSe Yes Spectrum 10 ES L160000P
Resources, Events & More
  • All

Application Note

Analysis of in-Service Greases with PerkinElmer Spectrum Two FTIR and Specac Pearl Liquid Transmission Accessory

Condition monitoring of lubricants with FTIR spectroscopy is a useful diagnostic tool that can help us to determine whether a lubricant is fit for purpose during its service life. However, analyzing lubricating grease is different to other less viscous lubricants due to the physical characteristics ...

PDF 839 KB
Characterization of Degradation Modes of Ethylene-Vinyl Acetate Encapsulant of Photovoltaic Modules by FTIR and TGA

Ethylene-vinyl acetate (EVA) has been a material of key importance as an encapsulant of photovoltaic (PV) modules used in the solar energy industry. Given that the encapsulant has such a vital role in maintaining the function of the PV module, it is important to understand and characterize the vario ...

PDF 1 MB
Characterization of Degradation Modes of Ethylene-Vinyl Acetate Encapsulant of Photovoltaic Modules by FTIR and TGA

Ethylene-vinyl acetate (EVA) has been a material of key importance as an encapsulant of photovoltaic (PV) modules used in the solar energy industry. EVA has many favorable characteristics as an encapsulant material. It is important to understand and characterize the various failure modes of differen ...

PDF 1 MB
Degradation Analysis of a Solid-State Electrolyte using TG-IR-GC/MS

Solid-state batteries (SSBs) are quickly becoming more popular as the industry looks to improve upon rechargeable battery performance and safety. These are batteries which use a solidstate electrolyte in place of the more conventional liquid electrolyte. Hyphenated techniques allow the user to not o ...

PDF 1 MB
Detecting Manuka Honey Adulteration Using Mid-Infrared Spectroscopy Webpage: Spectrum Two

Common adulterants found in Manuka honey include beet, corn and rice syrups. The differing photosynthetic pathways in the plants used to produce these adulterants generally means that different techniques are required to detect them. Mid-Infrared spectroscopy with Adulterant Screen™ technology, can ...

PDF 1 MB
Determination of DBPC and DBP in Transformer Insulating Oil According to ASTM D2668 and IEC 60666

Transformer insulating oil is often exposed to high temperatures due to the high voltage electrical applications for which it is commonly used. As a result, insulating oil degrades over time, reducing its ability to act as an insulator and possibly leading to equipment failure. 2,6-di-tert-butyl-p-c ...

PDF 1 MB
Determination of THC and CBD in Cannabis Flower

This work shows an on-site, rapid and low-cost technique for the accurate measurement of flower potency. FT-NIR spectroscopy provides rich information regarding the chemical composition of cannabis flower. When combined with chemometrics, the FT-NIR offers unparalleled speed and simplicity that cann ...

PDF 1 MB
Effects of Ionizable and Non-ionizable Excipients on Lyophilized RNA Formulations Using FTIR-ATR Technology

There are ongoing attempts to improve the storage stability of mRNA vaccines by converting them to solid forms using various drying methods. Lyophilization is one such method and has the potential to stabilize mRNA, but there are few reports that describe the interactions of lyophilized mRNA with ex ...

PDF 1 MB
Finding and Preventing PP Contamination Using FT-IR in Post-Consumer Recycled Plastic (HDPE)

High-density polyethylene (HDPE) is a commonly recycled plastic, notably from plastic drinking bottles. Recycled applications of HDPE are many and various including new packaging and textile fibres. But it is especially valued in automotive applications including fuel tanks, wiring, cables, pipes an ...

PDF 593 KB
Glycerol Adulteration with Diethylene Glycol

Glycerol (or glycerin) is a colorless, odorless liquid that is generally safe for human exposure and consumption. It has many uses in the food, pharmaceutical and personal care industries due to its range of versatile properties allowing it to act as a sweetener, lubricant and humectant. Unscrupulou ...

PDF 1 MB
IR Spec Analysis of Plastic Pharmaceutical Packaging Materials to USP 661.1

Packaging is defined as a means of providing protection, identification, and containment of a product during storage and transport until it is consumed. The pharmaceutical packaging industry has an estimated value of $68.7 billion, and when it comes to their packaging quality, it is essential that s ...

PDF 1 MB
Identification of Drugs of Abuse Using Infrared Spectroscopy

There are a wide variety of characterization techniques which may be used to identify drugs of abuse, including infrared spectroscopy, Raman spectroscopy, mass spectrometry, gas chromatography, x-ray diffractometry, immunoassays and urine dipstick tests. FT-IR spectroscopy provides one of the best s ...

PDF 162 KB
Polymer Recycling Compendium

This compendium provides example data and interpretations for the seven codes of recyclable polymers. DSC and TGA raw data files are provided so that the user can easily overlay their data with the expected results for new unprocessed plastics. This allows for a confirmation of identity and assists ...

PDF 1 MB
Routine Measurements of Adhesives Using ATR-FTIR Spectroscopy

Cyanoacrylate adhesives also known as ‘superglues’ are single-component reactive adhesives. They cure with the small amount of moisture on the surface of the components and very quickly bond on a variety of substances. FTIR spectroscopy is used extensively within the adhesives industry for research, ...

PDF 421 KB

Brochure

Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics. PerkinElmer is equipped to help the grain indus ...

PDF 6 MB
Microplastics Analysis Brochure

PerkinElmer offers comprehensive and innovative solutions for the identification and quantification of microplastics. Our portfolio includes leading technologies such as the Spectrum Two™ FTIR Spectrophotometer, the Spotlight™ 400 FTIR Imaging System, the NexION® ICP-MS and Hyphenated Technologies. ...

PDF 3 MB

Case Study

Customer Story: Western Norway University of Applied Sciences - Offering Students Latest Technology for Building Relevant Analytical Skills

For higher educational institutions to continue to attract the highest caliber of students it is critical to have up-to-date technologies accessible in teaching laboratories. Historically, operational budgets have been limited and with intermittent use, universities could not justify the purchase. H ...

PDF 849 KB

Guide

Battery Analysis Guide

This guide offers an overview of analyses required throughout the battery value chain - learn about innovative analytical solutions for testing every part of the battery, including the anode, cathode, binder, separator, and electrolyte. See the value in data generated from a variety of applications ...

PDF 2 MB

Poster

Advanced Solutions for Polymers and Plastics

This poster lays out our whole material characterization range for the analysis of polymers and plastics. Find ideal techniques and instruments at each stage in the polymer manufacturing process: Resin Development - Resin Manufacture - Compound Development - Compound Manufacture - Product Forming - ...

PDF 2 MB
Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...

PDF 1 MB

White Paper

Data Integrity – Spectrum 10 Enhanced Security (ES) Software for Infrared Spectroscopy

The FDA defines data integrity as “completeness, consistency, and accuracy of data. Complete, consistent, and accurate data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA)”. ALCOA itself has evolved to ALCOA Plus, which incorporates two of t ...

PDF 3 MB
Selection Criteria for Analytical Technologies that Meet Polymer Manufacture and Recycling Testing Needs

This white paper discusses what testing is required at each step in the polymer production lifecycle from R&D to manufacture to recycling. It explores the analytical technologies that will meet those testing needs, and important considerations to help you select the instrumentation that will provide ...

PDF 1 MB