PerkinElmer

Nebulizers

OF

For optimal performance and simple, reduced-cost maintenance, you'll find out nebulizers are one of the most important components in atomic spectroscopy instrumentation. All PerkinElmer nebulizer assemblies are adjustable and include easily-interchangable capillary assemblies.

  • Products and Services

  • Resources, Events & More

Narrow your results
Product Type
  • Accessories (95)
  • Consumables (160)
  • Service Parts (9)
Material
  • Alumina Ceramic (1)
  • Borosilicate Glass (10)
  • Corrosion-Resistant - Metal Body (2)
  • Corrosion-Resistant - Plastic Body (1)
  • CTFE (5)
  • Fused Silica (1)
  • Glass (15)
  • HF Resistant PEEK (2)
  • HF Resistant Polyimide (1)
  • High Sensitivity - Plastic Body (7)
  • Metal Body (4)
  • PEEK (10)
  • PFA (33)
  • Plastic Body (5)
  • Platinum Alloy - Metal Body (2)
  • PolyPro (1)
  • PTFE (11)
  • Quartz (6)
  • SilQ (1)
  • Stainless Steel - Metal Body (4)
Model Compatible With
  • AAnalyst 100 (7)
  • AAnalyst 200 (1)
  • AAnalyst 300 (7)
  • AAnalyst 400 (1)
  • AAnalyst 700 (8)
  • AAnalyst 800 (8)
  • ASXPRESS PLUS (1)
  • Avio 200 (23)
  • Avio 500 (23)
  • ELAN 5000 (14)
  • ELAN 6x00 (14)
  • ELAN 9000 (14)
  • ELAN DRCs (14)
  • Model 1100(B) (3)
  • Model 2100 (3)
  • Model 3100 (7)
  • Model 3110 (7)
  • Model 3300 (7)
  • Model 4100 (3)
  • Model 5000 (7)
  • Model 5100 PC (7)
  • NexION 1000 (36)
  • NexION 2000 (39)
  • NexION 300 (14)
  • NexION 350 (15)
  • Optima 2x00 DV (25)
  • Optima 3000 SCX (5)
  • Optima 3x00 DV (10)
  • Optima 3x00 RL (9)
  • Optima 3x00 XL (5)
  • Optima 4300 V (6)
  • Optima 4x00 DV (25)
  • Optima 5300 V (6)
  • Optima 5x00 DV (25)
  • Optima 7300 V (6)
  • Optima 7x00 DV (25)
  • Optima 8x00 (20)
  • PinAAcle 500 (9)
  • PinAAcle 900F (9)
  • PinAAcle 900H (9)
  • PinAAcle 900T (9)
  • PinAAcle 900Z (9)
Product Brand Name
  • Apex (2)
  • Ari Mist (1)
  • Conikal (3)
  • Cross-Flow (7)
  • DuraMist (2)
  • Eluo (2)
  • EzyFit (6)
  • EzyLok (1)
  • GemCone (4)
  • GemTip (13)
  • MEINHARD (26)
  • MicroFlow (25)
  • MicroMist (8)
  • Mira Mist (9)
  • OpalMist (5)
  • PerkinElmer (39)
  • Poly-Pro (1)
  • PolyCon (1)
  • SeaSpray (5)
  • Slurry (2)
  • Teledyne CETAC (1)
  • UniFit (6)
  • VeeSpray (1)
Product Group
  • Adapters (12)
  • Capillary Assemblies and Tubing (49)
  • Cleaning Tools (4)
  • End Caps (9)
  • Ferrules (3)
  • Gas Lines (1)
  • Impact Beads (2)
  • Nebulizer Assemblies (16)
  • Nebulizer Tips (4)
  • Nebulizers (98)
  • Needle Sliders (1)
  • O-Rings (13)
  • Other Replacement Parts (7)
  • Sample Introduction Kits (33)
  • Springs (3)
  • Venturi Tubes (4)
Technology Type
  • AA (20)
  • ICP-MS (36)
  • ICP-MS & ICP-OES (1)
  • ICP-MS, ICP-OES (10)
  • ICP-OES (37)
Type
  • Consumables (20)

"Nebulizers" 1-50 of 264 Products and Services

Sort
Per Page
PerkinElmer

1/4" Adapter for 3000 & ICP-MS f/Mira Mist

1/4" Swagelok Adapter for PE Optima 3000 series, PE Sciex ICP/MS

EzyFit connector 0.25 mm ID x 1.3 mm OD x 700 mm long

This product has a quantity of 10. Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.

UniFit Connector with 1.3mm OD x 0.50mm ID x 700mm Long Sample Tube - Quantity 10

Replacement connector and sample tubing for U-Series concentric nebulizers. Supplied as a pack of 10.

PEEK 1.0 mL/min DuraMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300/350/1000/2000/Optima 3x00 RL

This PEEK 1.0 mL/min DuraMist nebulizer is used with ELAN® 5000, 6x00, 9000, and DRCs ICP-MS, NexION® 1000, 2000, 300, and 350 ICP-MS, and Optima 3x00 RL ICP-OES series instruments.

Organics Sample Introduction Kit for Optima 8x00

This organics sample introduction kit includes core consumables and components used with Optima 8x00 ICP-OES series instruments.

6

6" Metal-Free Nebulizer Gas Line for NexION 2000/1000

Gas line for NexION® 2000 and 1000 ICP-MS concentric glass and quartz MEINHARD® nebulizers. Metal-free and 6 inches in length.
SeaSpray-MicroMist-Conikal-Slurry Nebulizer

1.0 L/min Flow Rate, 0.4mL/min Uptake Rate SeaSpray Nebulizer

This glass 0.4 mL/min SeaSpray nebulizer is used with ELAN® 5000, 6x00, 9000, and DRCs ICP-MS, NexION® 1000, 2000, 300, and 350 ICP-MS, and Optima 3x00 RL ICP-OES series instruments.
PFA MicroFlow Nebulizer for NexION

PFA 100 µL/min MicroFlow Nebulizer for NexION 2000/1000

This PFA 100 µL/min MicroFlow nebulizer, with integrated fluoropolymer capillaries, is used with NexION® 2000 and 1000 ICP-MS series instruments.
MEINHARD Type CT Q + Quartz Nebulizer

Concentric Type CT Q + Nebulizer for NexION 2000/1000

This quartz Concentric Type CT Q + nebulizer, with nebulizer gas line and barbed fitting, is used with NexION® 1000 and 2000 ICP-MS series instruments.
SeaSpray-MicroMist-Conikal-Slurry Nebulizer

Slurry Nebulizer 4mL/min for ELAN/NexION

The Slurry glass concentric nebulizer is ideal for specialized applications requiring the aspiration of slurries or suspensions. Its capillary bore is 50% larger than that of standard concentric nebulizers and this reduces the possibility of particle blockage while giving excellent signal stability.

Impact Bead for High Sensitivity Nebulizer with Pt/lr or Tantalum Capillary

Impact Bead for High Sensitivity Nebulizer with Pt/lr or Tantalum Capillary for PerkinElmer AAnalyst 100/300/700/800, 5100 PC, 5000,3300, 3110, 3100 4100, 2100, 1100(B)and earlier AA's. Included with High Sensitivity GemTip Nebulizer only. Inert plastic body with red adjusting ring
Quartz Asperon Spray Chamber

Single Cell Sample Introduction Kit with Software for NexION 2000/1000

This Single Cell sample introduction kit, software included, is for NexION® 2000 and 1000 ICP-MS series instruments.

Quick Disconnect Tubing with Swagelock

Included with Optima Low-flow GemCone nebulizer.
10-32 Union for MEINHARD Plus Nebulizer

10-32 Union for MEINHARD Plus Nebulizer for NexION 2000/1000

MEINHARD® Plus Nebulizer fitting for the NexION® 2000 and 1000 ICP-MS Concentric Nebulizer (N8152378).
Sample Intro Line for PFA-ST Nebulizer

0.5 mm I.D. Sample Intro Line for PFA-ST Nebulizer for NexION 2000/1000

Sample Introduction Line, with 0.5 mm inner diameter, for the NexION® 2000 and 1000 ICP-MS ESI PFA-ST Nebulizer. Includes fluoropolymer micro pump tubing fitting.

ST3 MicroFlow PFA nebulizer

The ST3 MicroFlow PFA nebulizer with external 1/4-28 threaded connector is designed for superior clog resistance and higher sensitivity compared to the standard PFA nebulizer. The PFA-ST MicroFlow nebulizer is made from high purity, HF resistant PFA.
PerkinElmer

Spring for High Sensitivity Nebulizers for PerkinElmer 4100, 2100 and 1100(B) AA Spectrometers

For sealing sample vials for temperatures up to 100 °C. Very low background peaks, lowest permeability, recommended for repetitive injections from the same vial. Includes aluminum caps and star springs.
Male CTFE Liquid Fitting

CTFE Liquid Fitting - male

CTFE Liquid fitting - male with barb end
MEINHARD HEN Single Cell Nebulizer

Nebulizer HEN

This product is part of a Single Cell Sample Introduction Kit for NexION 1000/2000.
PFA LC Microflow Nebulizer

PFA LC MicroFlow Nebulizer for NexION 2000/1000

This PFA LC MicroFlow nebulizer, with gas line and fittings, is used with NexION® 1000 and 2000 ICP-MS series instruments.
PFA Tubing for Nebulizer

50 uL/min self-asp capillary

50 µL/min self-aspirating sample capillary for ST nebulizer. 0. 20 mm i. d. , purple marker. For flow rates below 100 µL/min integrated capillary nebulizers, e. g. N8145102, may be optimal. ]

PEEK 0.4 mL/min DuraMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300/350/1000/2000/Optima 3x00 RL

This PEEK 0.4 mL/min DuraMist nebulizer is used with ELAN® 5000, 6x00, 9000, and DRCs ICP-MS, NexION® 1000, 2000, 300, and 350 ICP-MS, and Optima 3x00 RL ICP-OES series instruments.

High Sensitivity Nebulizer Assembly with Tantalum Capillary for PerkinElmer AAnalyst and Earlier AA Instruments

High Sensitivity plastic body nebulizer with tantalum capillary and complete assembly.
Cyclonic/Concentric Sample Introduction Module for Avio

Cyclonic/Concentric Sample Introduction Module for Avio 200

This sample introduction module, with cyclonic spray chamber and MEINHARD® concentric nebulizer technologies, includes core components used with Avio 200 ICP-OES series instruments.

Scott/Cross-Flow Sample Introduction Module for Avio

Scott/Cross-Flow Sample Introduction Module for Avio 500

This sample introduction module, with Scott spray chamber and GemTip Cross-Flow nebulizer, includes core components and consumables used with Avio 500 ICP-OES series instruments
MEINHARD UltraPure CT SilQ + Quartz Low Volume Nebulizer

Concentric Type CT SilQ + Nebulizer for NexION 2000/1000

This ultra high purity quartz Concentric Type CT SilQ + nebulizer, with nebulizer gas line and barbed fitting, is used with NexION® 1000 and 2000 ICP-MS series instruments.

Organics Sample Introduction Kit for Optima 2x00/4x00/5x00/7x00 DV

This organics sample introduction kit includes core consumables and components used with Optima 2x00 DV, 4x00 DV, 5x00 DV, and 7x00 DV ICP-OES series instruments.

MEINHARD Nebulizer Gas Line for Avio & Optima

MEINHARD Nebulizer Gas Line for Avio 200/500 & Optima 2x00/4x00/5x00/7x00 DV/8x00

This MEINHARD® nebulizer gas line is used with Avio 200 and 500 ICP-OES, and Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV and 8x00 ICP-OES series instruments.

PFA-50 MicroFlow nebulizer

PFA-50 MicroFlow nebulizer with integrated capillary. Self-aspirating PFA MicroFlow nebulizers are constructed entirely from chemically resistant fluoropolymers ideal for strong acids, alkalis, organics and high salt solutions. They are resistant to clogging and produce a fine aerosol for high transport efficiency and high sensitivity.
PFA Tubing for Nebulizer

200 uL/min self-asp capillary

200 µL/min self-aspirating sample capillary for ST nebulizer. 0.30 mm i.d., yellow marker
Female CTFE Liquid Fitting

CTFE Liquid Fitting - female

CTFE Liquid fitting - female with barb end
PerkinElmer

2 mm gas line with upchurch fittings for Mira Mist Nebulizer

2 mm gas line with UpChurch fingertight fittings for Mira Mist and Ari Mist nebulizers.
MEINHARD Nebulizer Clip Snapper for Avio & Optima

MEINHARD Nebulizer Clip Snapper for Avio 200/500 and Optima 2x00/4x00/5x00/7x00 DV/8x00 

This nebulizer clip snapper, for MEINHARD® nebulizers, is used with Avio 200 and 500 ICP-OES, and Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.

Nebulizer Cleaning Wires. Pkg 5

Made of soft alloy copper, these cleaning wires are specially deburred to prevent scratching of the orifices and internal components of the nebulizers while cleaning. Use only PerkinElmer cleaning wires to clean nebulizers.
PFA MicroFlow Nebulizer for NexION

PFA 20 µL/min MicroFlow Nebulizer for NexION 2000/1000

This PFA 20 µL/min MicroFlow nebulizer, with integrated fluoropolymer capillaries, is used with NexION® 2000 and 1000 ICP-MS series instruments.
Female Barb CTFE Fitting for Peripump Union, Qty. 1

Female Barb CTFE Fitting for Peripump Union for NexION 2000/1000

Peripump Union - Female Barb CTFE Fitting for the NexION® 2000 and 1000 ICP-MS MEINHARD® Plus Nebulizer (10-32 male threads). Quantity: 1
Male Barb CTFE Fitting for Peripump Union, Qty. 1

Male Barb CTFE Fitting for Peripump Union for NexION 2000/1000

Peripump Union - Male Barb CTFE Fitting for the NexION® 2000 and 1000 ICP-MS MEINHARD® Plus Nebulizer (10-32 male threads). Quantity: 1

Type C0.5 Glass Nebulizer for NexION

We offer MEINHARD® Concentric Nebulizers ideal for aqueous solutions and samples with few dissolved solids.
0.15 mm I.D. PFA-LC Nebulizer Capillary

0.15 mm I.D. Capillary for NexION 2000/1000 PFA-LC MicroFlow Nebulizer

PFA-LC MicroFlow Nebulizer Capillary, 0.15 mm inner diameter, for NexION® 2000 and 1000 ICP-MS series instruments.
PerkinElmer

Cyclonic/Concentric Sample Introduction Module for Avio 500

This sample introduction module, with cyclonic spray chamber and MEINHARD® concentric nebulizer, includes core components and consumabls used with Avio 500 ICP-OES series instruments.

Gem tip Cross-Flow II Tip Kits for Optima 8x00

The Tip Kit includes a clear sapphire sample tip and a red ruby argon tip. The tips are constructed of PEEK with the gem inserts noted for maximum corrosion resistance.

Viton O-Ring, 0.364in i.d., 0.070in. width

For use with Silicone Applications. For Spacer please order Part No. B3150531

"Nebulizers" 1-50 of 264 Products and Services

Per Page