XRpad2 3025 (In Development)

XRpad2 3025 Wireless a-Si X-Ray Detector

Our XRpad2 3025 is a wireless, lightweight, cassette-sized FPD with a 25 cm x 30 cm (10" x 12") imaging area.

Overview

XRpad2 3025 is a lightweight wireless cassette detector with advanced features enabling digital radiography as never seen before.

Featuring best-in-class 100 μm pixel size, direct deposition CsI scintillator and excellent DQE, XRpad2 3025 enables high resolution imaging with reduced X-ray exposure. Design of the second-generation XRpad® is lightweight, robust and ergonomic, permitting easy lifting from table top. Automatic Exposure Detection, on-board corrections, and wireless access point mode make system integration quick and simple.

New features of the XRpad2 3025 include fast preview, internal image storage, and magnetic connector for docking. Continuous imaging at up to ten frames per second facilitates advanced applications such as tomosynthesis, dual energy subtraction, and image stitching.

PerkinElmer Medical Imaging has partnered with OEM customers for more than 25 years to develop products for a wide range of X-ray applications. Let our digital imaging expertise work for you.

Applications
  • Digital Radiography

Features & Benefits

  • 25 cm × 30 cm (10” × 12”) image
  • High resolution 100 μm pixel pitch (5.0 lp/mm)
  • Direct deposition Csl, for excellent image quality
  • Up to 65,536 grey levels (16-bit ADC)
  • Automatic Exposure Detection (AED)
  • Wi-Fi interface (Station and Access Point modes)
  • Docking connector for GigE, power and sync
  • On-board pixel corrections and storage
  • Dynamic mode for tomosynthesis
  • Fast preview image
  • Robust and lightweight design
Disclaimer Icon

PerkinElmer flat panel X-ray detectors are components intended to be integrated into products by X-ray systems manufacturers. Systems manufacturers are responsible for qualifying and validating their products for intended uses and meeting all applicable regulatory requirements.

Specifications

Sensor
PanelAmorphous silicon active TFT-diode array
ScintillatorDirect deposition CsI:Tl
Pixel Matrix2508 × 3004
Pixel Pitch100 μm
Electronics
AmplifiersLow noise ASICs with user selectable gains
ADC16-bit
Image Transfer TimeWired: 300 ms; Wireless: 2000 ms
On-board Memory1 GB DDR3, 8 GB SDHC card
Mechanical
SizeISO 4090 for 25 cm × 30 cm (10" × 12") cassette size
Active Area248.0 mm × 297.6 mm
External Dimensions282 mm (w) × 332 mm (l) × 15.5 mm (h)
Weight1.8 kg (4 lbs)
HousingAluminum frame with carbon-fiber entrance window
Communications
Status DisplayOLED display with Wi-Fi, LAN, battery, and sensor indicators
Wireless Data I/F802.11n Wi-Fi standard at 5 GHz
Wired Data I/FGigE, trigger and power via optional docking connector
X-ray I/FIntegrated X-ray trigger control / Automatic Exposure Detection
Imaging Performance
Typical DQE75% (0 cy/mm), 60% (1 cy/mm), 40% (3 cy/mm) for RQA5
Typical MTF70% (1 cy/mm), 40% (2 cy/mm), 15% (4 cy/mm) for RQA5
Limiting Resolution5 cy/mm
Advanced Features
Dynamic Mode10 fps at 200 μm resolution
On-board CorrectionsOffset, gain and defective pixel
On-board StorageImage storage with tagging
Fast Preview4 × 4 binned quick preview image
Environmental
Temperature10 °C to 35 °C operating
Humidity10% to 85% operating
Ingress ProtectionIPX4 rated (protection against splashing water)
Accessories
BatteryRechargeable battery, 11.1 V
Battery ChargerExternal two bay charger 100 - 240 V AC 50/60 Hz
Interface and Power UnitOptional IPU-2 external power supply 100 - 240 V AC, GigE, and X-ray I/F
Regulatory
StandardsEN 60601-1:2006/AC:2010, EN 60601-1-2:2007,
FCC part 2 subpart J, FCC part 15 subpart B/C/E,
ETSI EN 301 893 V.1.7.1 (2012), ETSI EN 301 489-1 V1.9.2 (2011), ETSI EN 301 489-17 V2.2.1 (2012), EN ISO 10993-5:2009,