XRpad2 3025 HWC (In Development)

XRpad2 3025 Wireless a-Si X-Ray Detector

Our XRpad2 3025 HWC is a wireless, light weight, cassette-sized FPD with a 25 cm x 30 cm (10" x 12") imaging area.


XRpad2 3025 HWC is a wireless, lightweight, cassette-sized flat panel detector for digital radiography based on a second-generation XRpad® design from PerkinElmer.

Featuring a 7.4 million pixel image matrix, a best-in-class 100 μm pixel pitch, and a direct deposited CsI scintillator, the PerkinElmer XRpad2 3025 HWC provides exceptional image quality. A 25 × 30 cm2 imaging area is provided, along with a removable rechargeable battery. A robust and lightweight aluminum frame with carbon-fiber entrance window and back cover allow for easier placement and cleaning. Automatic Exposure Detection, on-board corrections, and wireless access point mode simplify integration.

We have over 25 years of experience partnering with customers to develop products in a wide range of X-ray applications. Let our digital imaging expertise work for you.

  • Digital Radiography


Features & Benefits

  • 25 cm × 30 cm (10” × 12”) image
  • High resolution 100 μm pixel pitch (5.0 lp/mm)
  • Direct deposition Csl, for excellent image quality
  • Up to 65,536 grey levels (16-bit ADC)
  • Automatic Exposure Detection (AED)
  • Wi-Fi interface (Station and Access Point mode)
  • Docking connector for GigE, power and sync
  • On-board pixel corrections and storage
  • Sequence mode for tomosynthesis
  • Fast preview image
  • Robust and lightweight design
Disclaimer Icon

PerkinElmer flat panel X-ray detectors are components intended to be integrated into products by X-ray systems manufacturers. Systems manufacturers are responsible for qualifying and validating their products for intended uses and meeting all applicable regulatory requirements.


PanelAmorphous silicon active TFT-diode array
ScintillatorDirect deposition CsI:Tl
Pixel Matrix2508 × 3004
Pixel Pitch100 μm
AmplifiersLow noise ASICs with user selectable gains
Image Transfer TimeWired: 300 ms; Wireless: 2000 ms
On-board Memory1 GB DDR3, 8 GB SDHC card
SizeISO 4090 for 25 cm × 30 cm (10" × 12") cassette size
Active Area248.0 mm × 297.6 mm
External Dimensions282 mm (w) × 332 mm (l) × 15.5 mm (h)
Weight1.8 kg (4 lbs)
HousingAluminum frame with carbon-fiber entrance window
Status DisplayOLED display with Wi-Fi, LAN, battery, and sensor indicators
Wireless Data I/F802.11n Wi-Fi standard at 5 GHz
Wired Data I/FGigE, trigger and power via optional docking connector
X-ray I/FIntegrated X-ray trigger control
Automatic Exposure Detection
Imaging Performance
Limiting Resolution5 cy/mm
Typical MTF70% (1 cy/mm), 40% (2 cy/mm), 15% (4 cy/mm) for RQA5
Typical DQE75% (0 cy/mm), 60% (1 cy/mm), 40% (3 cy/mm) for RQA5
Advanced Features
Sequence Mode10 fps (2 × 2 binned)
On-board CorrectionsOffset, gain and defect pixel
On-board StorageImage storage with tagging
Fast Preview4 × 4 binned quick preview image
Temperature10 °C to 35 °C operating
Humidity10% to 85% operating
Ingress ProtectionIPX4 rated (protection against splashing water)
BatteryRechargeable battery, 11.1 V
Battery ChargerExternal two bay charger 100 - 240 V AC 50/60 Hz
Interface and Power UnitOptional IPU-2 external power supply 100 - 240 V AC, GigE, and X-ray I/F
StandardsEN 60601-1:2006/AC:2010, EN 60601-1-2:2007, FCC part 2 subpart J, FCC part 15 subpart B/C/E, ETSI EN 301 893 V.1.7.1 (2012), ETSI EN 301 489-1 V1.9.2 (2011), ETSI EN 301 489-17 V2.2.1 (2012), EN ISO 10993-5:2009, EN ISO 10993-10:2010