Use the highest quality reagents available today to screen for core newborn disorders as well as those detected by expanded screening. Our reagents are the industry standard for analytical performance and reliability in detecting congenital diseases that are treatable only when identified during the first days of life.

Products & Services (40)
Filters:

Filters :

Application
  • Newborn Screening (4)
Product Brand Name
  • GSP® (8)
  • MSMS Kit (2)
  • NeoBase™ (4)
  • NeoLSD™ (2)
Detection Method
  • DELFIA (8)
  • Enzymatic (4)
Sample Type
  • Dried blood spots (1)
Assay points(200-50,000)
  • 500 (1)
Automation Compatible
  • Yes (1)
Disorders
  • Biotinidase (BTD) Deficiency (3)
  • Congenital Adrenal Hyperplasia (CAH) (2)
  • Congenital Hypothyroidism (6)
  • Cystic Fibrosis (4)
  • Duchenne Muscular Dystrophy (1)
  • Fabry (2)
  • Galactosemia (6)
  • Gaucher (2)
  • Hemoglobinopathies (4)
  • Krabbe (2)
  • Metabolic Disorders (5)
  • MPS-I (2)
  • Niemann-Pick A/B (2)
  • Phenylketonuria (1)
  • Pompe (2)
  • SCID (3)
Format
  • Microplates (1)
Technology Type
  • MSMS (2)

1-12 of 40 Products & Services

Sort by

  • DX-Newborn-screening-kits_320px

    Neonatal Total Galactose kit (10 plate)

    Neonatal Total Galactose kit is intended for the quantitative determination of total galactose (galactose and galactose-1-phosphate) concentrations in blood specimens dried on filter paper as an aid in screening newborns for galactosemia.
  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal 17α-OHP kit (12 plate)

    This kit is intended for the quantitative determination of human 17-OH-progesterone in blood specimens dried on filter paper as an aid in screening newborns for congenital adrenal hyperplasia (CAH) using the 1235 AutoDELFIA® automatic immunoassay system.
  • PerkinElmer

    Neonatal Biotinidase kit (10 plate)

    Neonatal Biotinidase kit is intended for the semi-quantitative determination of biotinidase activity in blood specimens dried on filter paper as an aid in screening newborns for biotinidase deficiency.
  • NeoBase Non derivatized MSMS kit

    NeoBase Non-derivatized MSMS kit

    The NeoBase MSMS kit is intended for the quantitative determination of up to 11 clinically significant amino acids and 31 clinically significant acylcarnitines, detecting more than 30 different metabolic diseases from a single dried blood spot sample using the MS/MS tandem mass spectrometer.
  • DX-Newborn-screening-kits_320px

    DELFIA® Neonatal Thyroxine (T4) kit (10 plate)

    This kit is intended for the quantitative determination of human thyroxine (T4) in blood specimens dried on filter paper as an aid in screening newborns for congenital (neonatal) hypothyroidism.
  • PerkinElmer

    RESOLVE Hemoglobin kit (135 tests)

    The RESOLVE Hemoglobin Kit use isoelectric focusing (IEF) to detect hemoglobin variants in whole blood, cord blood or blood spot samples.
  • GSP Total Galactose TGAL kit tumma

    GSP® Neonatal Total Galactose kit

    The GSP Neonatal Total Galactose (TGAL) assay is intended for the quantitative determination of both galactose and galactose-1-phosphate in blood specimens dried on filter paper. The assay is used with the GSP® instrument as an aid in screening for deficiency in any of the three enzymes involved in galactose metabolism.
  • GSP Biotinidase kit

    GSP® Neonatal Biotinidase kit

    The GSP Neonatal Biotinidase assay is intended for the quantitative determination of biotinidase activity in blood specimens dried on filter paper as an aid in screening newborns for biotinidase deficiency by using the GSP® instrument.
  • DX-Newborn-screening-kits_320px

    NeoGram Derivatized Assay Solutions

    The NeoGram Derivatized Assay Solutions are intended for in vitro diagnostic use with the NeoGram Amino Acids and Acylcarnitines (AAAC) Tandem Mass Spectrometry Kit. The product includes NeoGram AAAC Flow Solvent, NeoGram AAAC Extraction Solution, NeoGram AAAC Reconstitution Solution and 3.0 N HCL in n-butanol.
  • GSP Neonatal IRT kit

    GSP® Neonatal IRT kit

    The GSP Neonatal IRT assay allows the quantitative determination of IRT from dried blood spot specimens, and is intended as an aid in screening for cystic fibrosis.
  • DX-Newborn-screening-kits_320px

    AutoDELFIA Neonatal hTSH kit (12 plate)

    This kit is intended for the quantitative determination of human thyroid stimulating hormone (hTSH) in blood specimens dried on filter paper as an aid in screening newborns for congenital (neonatal) hypothyroidism using the 1235 AutoDELFIA® automatic immunoassay system.
  • 3311-0010 GSP Creatine Kinease MM kit

    GSP Neonatal Creatine Kinase -MM kit

    The GSP Neonatal Creatine Kinase –MM kit is a solid phase, two-site fluoroimmunometric assay based on the direct sandwich technique. Analyte is bound to monoclonal CK-MM specific antibodies. The fluorescence signal is proportional to the analyte concentration in the sample.