Solid Phase Extraction (SPE)

Why PerkinElmer SPE?

Consistently. Excellent. Performance.
The unsurpassed reproducibility of PerkinElmer SPE solutions is the result of a unique bed-packing technique and spherical media. Columns are evenly and consistently filled with particles sized for optimum distribution, delivering a level of performance unattainable with the irregularly shaped silica used in competitive solutions.

PerkinElmer's homogeneous filling and mono-dispersed spherical media not only provide unparalleled reproducibility, they also deliver superior performance. Our Precise-Bed Technology™ provides precision and manufacturing tolerances of +/- 1%, ensuring guaranteed repeatability and optimized recovery reproducibility. Sample diffusion through the spherical media is better than in other systems, improving flow efficiency and avoiding clogging due to fines. This enables smaller sample sizes to be used without compromising recovery levels, dramatically reducing solvent volumes, analytical costs and processing times.

With PerkinElmer SPE solutions, you can work faster and more cost effectively, all while experiencing the complete recovery, reproducibility and reliability you need for consistently excellent results.

Video PlatformVideo ManagementVideo SolutionsVideo Player

Ideal for a broad array of analytes and matrices, SPE solutions are available in a variety of formats including Large Reservoir Capacity (LRC) columns, Polypropylene (PP) columns and cartridges, 96 well plate format, and glass columns. Each technology is offered with a wide selection of polymer and silica sorbents. Varied column capacities and bed weights allow you to perform scalable analyses depending upon your required detection limits.

For sample preparation in pesticide residue analysis easy-to-use dispersive SPE kits are available. These kits apply the QuEChERS methodology (Quick, Easy, Cheap, Effective, Rugged, Safe) using any of the three standard QuEChERS methods: Original QuEChERS method, American AOAC Standard (Official Method 2007.01) QuEChERS method and European Standard (EN 15662) QuEChERS method.


Guides


View Technologies

SPE Supra-Clean 300Å C4 Column

Supra-Clean™ WC4 Less hydrophobic than C-8 or C-18. For extraction of peptides and proteins.  View more

SPE Supra-Clean Application Packs

Ideal for extraction of known entities from a variety of matrices, our SPE Supra-Clean Application Packs...  View more

SPE Supra-Clean Column Selection Kits

Selection kits enable quick column selection for development of reproducible and repeatable SPE methods.  View more

SPE Supra-Clean Florisil (FL-S) Columns

PerkinElmer's Supra-Clean® Florisil (FL-S) Solid Phase Extraction (SPE) products are recommended for...  View more

SPE Supra-Clean Florisil (FL-S) Pesticide Grade Columns

PerkinElmer's Supra-Clean® Florisil Pesticide (FL-S) Solid Phase Extraction (SPE) products are recommended...  View more

SPE Supra-Clean Mixed-Mode (MM1, MM2, MM3) Column

Mixed mode sorbents exhibit the greatest selectivity. Ion exchange and hydrophobic chains are bonded...  View more

SPE Supra-Clean Weak Cation Exchange (WCX) Column

Supra-Clean™ WCX - Ion-exchange retention is based on ionic interaction. This sorbent creates a strong...  View more

SPE Supra-Clean® Amino (NH2-S)

PerkinElmer's Supra-Clean® Amino (NH2-S) Solid Phase Extraction (SPE) products are recommended for extracting...  View more

SPE Supra-Clean® C18

PerkinElmer's Supra-Clean®C18 (C18-S) Solid Phase Extraction (SPE) products are recommended for extracting...  View more

SPE Supra-Clean® Cyano CN-S Columns

PerkinElmer's Supra-Clean® Cyano (CN-S) Solid Phase Extraction (SPE) products are recommended for extracting...  View more

SPE Supra-Clean® Mixed-Mode MM1

PerkinElmer's Supra-Clean® Mixed Mode (MM1) Solid Phase Extraction (SPE) products are recommended for...  View more

SPE Supra-Clean® Mixed-Mode MM2 Columns

SPE Supra-Clean Mixed Mode (MM2) silica based Columns, 60 um particle size, exchange capacity 0.10 ...  View more

SPE Supra-Clean® Mixed-Mode MM3 Columns

PerkinElmer's Supra-Clean® Mixed Mode (MM3) Solid Phase Extraction (SPE) products are recommended for...  View more

SPE Supra-Clean® Phenyl (PH-S)

PerkinElmer's Supra-Clean® Phenyl (PH-S) Solid Phase Extraction (SPE) products are recommended for extracting...  View more

SPE Supra-Clean® Polyamine (P6) Columns

PerkinElmer's Supra-Clean® Polyamine (P6) Solid Phase Extraction (SPE) products are recommended for ...  View more

SPE Supra-Clean® REC18 (full accessible surface)

PerkinElmer's Supra-Clean® High Recovery REC18 Solid Phase Extraction (SPE) products are recommended...  View more

SPE Supra-Clean® Silica (SI-S) Cartridge (full accessible surface)

PerkinElmer's Supra-Clean® Silica (SI-S) Solid Phase Extraction (SPE) products are recommended for extracting...  View more

SPE Supra-Clean® Strong Anion Exchange (SAX)

PerkinElmer's Supra-Clean® Strong Anion Exchange (SAX) Solid Phase Extraction (SPE) products are recommended...  View more

SPE Supra-Clean® Strong Cation Exchange (SCX)

PerkinElmer's Supra-Clean® Strong Cation Exchange (SCX) Solid Phase Extraction (SPE) products are recommended...  View more

SPE Supra-Poly Extreme Capacity 1500 m2/g (XC) Column

Supra-Poly™ XC 1500 m2/g Highest Surface Area available Xtrem Capacity > 30% Universal Polymer...  View more

SPE Supra-Poly® Environmental AEV Columns

PerkinElmer's Supra-Poly® Environmental (AEV) polystyrene-co-2-hydroxyethyl methacrylate (PSHEMA) Solid...  View more

SPE Supra-Poly® Extra Wide Particle 1200 m2/g (XWP)

PerkinElmer's Supra-Poly® Extreme Capacity Wide Pore (XWP) polystyrene-divinylbenzene (PSDVB) Solid ...  View more

SPE Supra-Poly® Extreme Capacity 1500 m2/g (XC)

PerkinElmer's Supra-Poly® Extreme Capacity (XC) polystyrene-divinylbenzene (PSDVB) Solid Phase Extraction...  View more

SPE Supra-Poly® HLB (Hydrophilic/Lipophilic Balanced)

PerkinElmer's Supra-Poly HLB (Hydrophilic/Lipophilic Balanced) Solid Phase Extraction (SPE) Kits are...  View more

SPE Supra-Poly® Hydrophilic (ATH) Columns

PerkinElmer's Supra-Poly® Hydrophilic (ATH) Solid Phase Extraction (SPE) products are recommended for...  View more

SPE Supra-Poly® Lipophilic (ATL) Columns

PerkinElmer's Supra-Poly® Lipophilic (ATL) polystyrene-divinylbenzene (PSDVB) Solid Phase Extraction...  View more

SPE Vacuum Pumps, Manifolds and Accessories

PerkinElmer SPE Vacuum Manifolds allow multiple samples to be processed simultaneously by conveniently...  View more

Supra-Clean® LCC Columns

PerkinElmer's Supra-Clean® LCC Solid Phase Extraction (SPE) products are recommended for extracting ...  View more